- Eight channels, 4 voltage & 4 current
- Intuitive color touch screen
- Light weight — About 4 pounds, 2 kg — with rugged rubber boot
- AC/DC applications
- Samples at 256 samples/cycle
- Independent voltage & current triggering, cross triggering
- High-speed sampling and data capture (1 microsecond/channel)
- Oscilloscope-like high speed transient detection (Dranetz 658-like and BMI-8800 like)
- Detailed event characterization of RMS variations and transients
- THD/harmonic spectrum and TID/interharmonics spectrum to the 63rd at 50/60 Hz
- Captures IEEE 1459 parameters for non-sinusoidal and advanced power systems
- Battery or AC mode
- Built in UPS battery with external charger
- Available with up to 4 GB Compact Flash Memory
- Available languages — English, French, Italian, German, Spanish, Swedish, Polish, Thai, Korean, Finnish, Japanese, Chinese (Traditional and Simplified)
- DRAN-VIEW enabled (Windows 7, 8, 10)
- Measures flicker according to IEC 61000-4-15
- Complies with IEEE 1159, IEEE 519, IEEE 1453
- Complies with IEC 61000-4-30 Class A and EN50160
- Instrument available in 400 Hz measurement version (PX5-400)
General Specifications
- Size (HxWxD): 12″ x 2.5″ x 8″ (30cm x 6.4cm x 20.3 cm)
- Weight: 4.2 pounds (1.9 kg)
- Operating Temperature: 0 -50 (32 to 122 )
- Storage Temperature: -20 to 55 (4 to 131 F)
- Humidity: 10 to 90% non-condensing
- System Time Clock-Crystal controlled-1 second resolution
- Charger /Battery Eliminator: 90-264 VAC 47-63 Hz
- Display: LCD color touch screen
- Memory options (must have one): Removable compact flashcard
Power Quality Triggers
- Cycle-by-cycle analysis
- 256 samples/cycle; 1/2 cycle RMS steps
- L-L, L-N, N-G RMS Variations: Sags/swells/interruptions)
- RMS Recordings V&I (32 pre-fault, 10K post-fault cycles)
- Waveshape Recordings (2/6/2 cycles)
- Low and Medium Frequent Transients – V&I
- High Frequency Transients – V&I, 3% FS trigger
- Harmonics Summary Parameters
- Cross trigger V & I channels
- RMS Event Characterization (IEEE or IEC)
- Transient Event Characterization (1)
Measured Parameters
- (4) differential inputs, 1-600 Vrms, AC/DC, 0.1% rdg + 0.05% FS, 256 samples/cycle, 16 bit ADC
- (4) inputs with CTs 0.1-6000 Arms CT-dependent, AC/DC, 0.1%rdg + CTs, 256 samples/cycle, 16 bit ADC
- 1 MHz High Speed Sampling, 14 bit ADC, 1%FS
- Frequency Range, 10m Hz resolution, 15-20 Hz, 45-65 Hz, or 350-450 Hz
- Phase Lock Loop – Generator tracking
- Phase Lock Loop – Standard PQ mode
- Monitoring/Compliance
- IEEE 1159
- IEC 61000-4-30 Class A
- EN50160 Quality of Supply
- Current Inrush / Energization
- Voltage Fault recording
- Long Term Monitoring
- Continuous Data Logging w/min/max/avg
Distortion/Power/Energy
- W, VA, VAR, TPF, DPF, Demand, Energy, etc.
- IEEE 1459 Parameters of distorted and unbalanced
- Harmonics/Interharmonics per IEC 1000-4-7
- THD/Harmonic Spectrum (V,I,W) to 63rd at 50/60Hz; 16th at 400Hz
- TID /Interharmonic Spectrum (V,I) to 63rd at 50/60Hz; 16th at 400Hz
- Flicker per IEC 1000-4-15 (Pst,Plt,Sliding Plt)
- Crest Factor, K Factor, Transformer Derating Factor, Telephone Interference Factor
- Unbalance (max. rms deviation) & sequencing components
- 5 User Spec Harmonics or Signaling Frequency
- Vector/Arithmetic/Coincident Parameters
Available Languages
English, French, Italian, German, Spanish, Swedish
The Power Xplorer uses digitized high-speed sampling to capture and analyze microsecond-wide transients (Dranetz 658-like and BMI 8800-like). The Power Xplorer delivers a full profile, with events time stamped to the millisecond of the entire transient, to pinpoint the exact source and cause of the event.
The Power Xplorer has been designed to meet the most advanced power quality standards, including IEEE 1159, IEC 61000-4-30 Class A and EN50160. A statistical output is produced to quickly verify compliance with international quality-of-supply standards and benchmark power quality.