The Power Xplorer integrates the most advanced feature set available in a power monitoring instrument, with an easy-to-navigate, color graphical user interface. With high-speed sampling and data capture (1 microsecond/channel), this 8-channel workhorse simultaneously captures and characterizes thousands of parameters, using a range of standard and customizable operating modes. The unique measurement capabilities of the Power Xplorer include capture of low-medium-high frequency transients through peak, waveshape, rms duration and adaptive high-speed sampling, as well as power measurements to clearly characterize voltage harmonics, non-sinusoidal and unbalanced systems.
The Power Xplorer integrates the most advanced feature set available in a power quality monitoring instrument, with an easy-to-navigate, color graphical user interface. With high-speed sampling and data capture (1 microsecond/channel), this 8-channel workhorse simultaneously captures and characterizes thousands of parameters, using a range of standard and customizable operating modes. The unique power quality measurement capabilities of the Power Xplorer include capture of low-medium-high frequency transients through peak, waveshape, rms duration and adaptive high-speed sampling, as well as power measurements to clearly characterize voltage harmonics, non-sinusoidal and unbalanced systems.
See the PX5 up close and personal. Schedule your private, personal on-site PX5 demonstration today.
The Power Xplorer uses digitized high-speed sampling to capture and analyze microsecond-wide transients (Dranetz 658-like and BMI 8800-like). The Power Xplorer delivers a full profile, with events time stamped to the millisecond of the entire transient, to pinpoint the exact source and cause of the event.
The Power Xplorer has a built-in event characterizer that directly supports troubleshooting and the gathering of survey data—for improving power quality and equipment reliability.
A drawback of capacitors is that they yield oscillatory transients when switched. These transients can propagate through the local power system, causing damage to equipment and processes. The Power Xplorer captures and identifies these fast transients.
The Power Xplorer measures the full range of arithmetic, vector and sequencing parameters contained in IEEE 1459, to evaluate distortion and restore balanced loads.
The Power Xplorer captures flicker data per IEC 6100-4-15, which can be further evaluated using Dran-View visualization, analysis and reporting software.
The Power Xplorer has been designed to meet the most advanced power quality standards, including IEEE 1159, IEC 61000-4-30 Class A and EN50160. A statistical output is produced to quickly verify compliance with international quality-of-supply standards and benchmark power quality.
The Power Xplorer captures detailed harmonics, interharmonics and subharmonics to effectively troubleshoot the complex problems caused by these events.
Training CD for PowerGuide 4400 and PowerXplorer (PX5)
Flash Card Memory provides removable memory of all saved data. The new flash card memory gives you greater capacity for data storage. Available in sizes from 256Mb
Soft carrying case. Rugged cordura nylon carry case holds PX5 / 4400, voltage probes, CTs, and manual. Ideal for field service, industrial applications.
Portable lockable case. Rugged, weatherproof case (NEMA 4x) for harsh environments. Includes multi-conductor voltage measurement and AC power cables. Ideal for utility substation measurements, outdoor jobs.
(CTIC-LPC Cable, for current, is optional)
Reusable shippping container. Protects the analyzer during repeated shipping. Complies with NSTA Project 1A vibration and drop specification. Includes space for accessories. Ideal for 4300s that are shared between offices or carried in trucks and car trunks.
Current probe, 1A-10A RMS 40Hz-5kHz (not for transient capture) Max conductor size 15mm
Current probe, 10A-500A RMS 40Hz-5kHz (not for transient capture) Max conductor size 50mm
Current probe, 300A - 3000A RMS 40Hz-5kHz (not for transient capture) Max conductor size 72mm
Voltage cable accessory pack Voltage measurement cable for direct connection to standard 120VAC single phase outlet. Includes four (4) jumper cables for various three-phase connections.
Current probe, 1A-30A RMS, 48Hz-10kHz, Max conductor size 20mm Requires cable adaptor CA4300
Current probe, 50A-300A RMS 30Hz-5kHz; Max conductor size 52mm Requires cable adaptor CA4300
Current probe, 10A - 1000A RMS 30Hz-5kHz; Max conductor size 54mm Requires cable adaptor CA4300
Call factory for sizes and ranges. Requires adapter cable CA4300BNC
Isolated communications module RS232 serial interface between PP4300 and PC or printer.
USB-FiberOptic Adapter
LAN-FiberOptic Adapter
Current probe, 200A - 3000A RMS 30Hz-5kHz; Max conductor size 65mm Requires cable adaptor CA4300