PowerVisa

PowerVisa

Equipped with 8 independent channels, the 3-phase PowerVisa is the only advanced power monitoring instrument to incorporate a color touch screen into its lightweight design. Automated setups provide instant detection of circuits and configurations, ensuring that the instrument is ready to successfully collect data. Users can select the length and mode of data collection, including troubleshooting, data logging, power quality surveys, energy and load balancing.

PowerVisa Product Video

The 3-phase PowerVisa power quality analyzer is equipped with 8 independent channels and a color touchscreen. Automated setups are included to provide instant detection of circuits and configurations, insuring that the instrument is ready to successfully collect data.

Users can select the length and mode of data collection including troubleshooting, data logging, power quality surveys and energy and load balancing.

See the PowerVisa up close and personal. Schedule your private, personal on-site PowerVisa demonstration today.

Features & Highlights

  • Eight channels, 4 voltage & 4 current
  • Intuitive color touch screen
  • Light weight — About 4 pounds, 2 kg — with rugged rubber boot
  • AC/DC applications
  • Automated setups for "out of the box" instrument readiness
  • Unique "report card" annunciator that instantly characterizes events
  • Samples at 256 samples/cycle
  • Independent voltage & current triggering, cross triggering
  • Capture of low-medium frequency transients
  • THD/harmonic spectrum and TID/interharmonics spectrum to the 63rd
  • Remote communications—RS-232, Ethernet or USB
  • Battery or AC mode
  • Built in UPS battery with external charger
  • Available with up to 4GB Compact Flash Memory
  • Available languages — English, French, Italian, German, Spanish, Swedish, Polish, Thai, Korean, Finnish, Japanese, Chinese (Traditional and Simplified)
  • DRAN-VIEW enabled (Windows 2000, XP, Vista, 7)
  • Complies with IEEE 1159, IEEE 519, IEEE 1453
  • Complies with IEC 61000-4-30 Class A and EN50160
  • Measures flicker according to IEC 61000-4-15; measures harmonics according to IEC 61000-4-7
  • Measures wide range of parameters, including crest factor, K factor, transformer derating factor and telephone interference factor

Specifications for the PowerVisa

Measured Parameters

  • (4) differential inputs, 1-600V rms, AC/DC, 0.1% rdg +0.05% FS , 256 samples/cycle, 16bit ADC
  • (4) inputs with CTs 0.1-3000A rms, AC/DC, 256s/c, 0.1% rdg + CTs, 16 bit ADC
  • Frequency range, 10mHx resolution, 45-65 Hz
  • Phase Lock Loop - Standard PQ mode

Monitoring/Compliance

  • IEEE 1159
  • IEC 61000-4-30
  • EN50160
  • Current Inrush / Energization
  • Voltage Fault recording
  • Quality of Supply (EN50160 or annunciator)
  • Long Term Monitoring
  • Continuous Data Logging w/min/max/avg

Distortion/Power/Energy

  • W, VA, VAR, TPF, DPF, Demand, Energy
  • Harmonics/Interharmonics per IEC 1000-4-7
  • THD/Harmonic Spectrum (V,I,W) to 63rd
  • TID/Interharm. Spectrum (V,I) to 63rd
  • Flicker per IEC 1000-4-15 (Pst,Plt,Sliding Plt)
  • CF, KF, TDF, TIF
  • Unbalance (rms dev. & sequencing components)

Power Quality Triggers

  • Cycle-by-cycle analysis
  • 256 samples/cycle; 1/2 cycle RMS steps
  • L-L, L-N, N-G RMS Variations: Sags/swells/interruptions)
  • RMS Recordings V& I (x/x/x cycles)
  • Waveform Recordings (2/6/2 cycles)
  • Low and Medium Freq Transients - V & I
  • Harmonics Summary Parameters
  • Cross trigger V & I channels
  • RMS Event Characterization (IEEE or IEC)

General Specifications

  • Size (HxWxD): 12" x 2.5" x 8" (30cm x 6.4cm x 20.3 cm)
  • Weight: 3.8 pounds(1.8 kg)
  • Operating Temperature: 0 -50 (32 to 122 )
  • Storage Temperature: -20 to 55 (4 to 131 F)
  • Humidity: 10 to 90% non-condensing
  • System Time Clock: Crysal controlled, 1 second resolution
  • Charger /Battery Eliminator: 90-264 VAC 47-63 Hz
  • Display: LCD color touch screen
  • Memory options (must have one): 256M removable compact flashcard

Applications for the PowerVisa

Typical Applications

Equipment Performance Testing

Equipment Performance Testing

Determining the availability and compatibility of facility power prior to the installation of new equipment is simplified using the PowerVisa 440. The instrument incorporates advanced features such as RMS triggers, low/medium frequency transients, and cross triggering between channels used to demonstrate that power mitigation devices such as UPSs are operating properly.

 

Energy Surveys

Energy Surveys

The PowerVisa 440 is an invaluable tool for performing energy surveys, including monitoring energy consumption, usage patterns, peak demands and the activation of large loads to reduce electricity costs.

 

Compliance Monitoring

Compliance Monitoring

The PowerVisa 440 has been designed to meet the most advanced power quality standards, including IEEE 1159, IEC 61000-4-30 Class A and EN50160.

 

Troubleshooting

Troubleshooting

The PowerVisa 440’s unique annunciator “report card” provides instant power quality answers in the field. Data is presented in color-coded categories to quickly identify areas of concern, identified in red. Drill down for more detailed information by simply touching the graphical screen.

 

Options and Accessories for the PowerVisa

Options & Accessories

Training CD
Training CD

Training CD for PowewrGuide 4400, PowerXplorer (PX5) and PowerVisa 440

Flash Card Memory
Flash Card Memory

Flash Card Memory provides removable memory of all saved data. The new flash card memory gives you greater capacity for data storage. Available in sizes from 256Mb

SCC 4300
SCC 4300

Soft carrying case. Rugged cordura nylon carry case holds PX5 / 4400, voltage probes, CTs, and manual. Ideal for field service, industrial applications.

LPC 4300
LPC 4300

Portable lockable case. Rugged, weatherproof case (NEMA 4x) for harsh environments. Includes multi-conductor voltage measurement and AC power cables. Ideal for utility substation measurements, outdoor jobs.
(CTIC-LPC Cable, for current, is optional)

RSC 4300
RSC 4300

Reusable shippping container. Protects the analyzer during repeated shipping. Complies with NSTA Project 1A vibration and drop specification. Includes space for accessories. Ideal for 4300s that are shared between offices or carried in trucks and car trunks.

TR-2510
TR-2510

Current probe, 1A-10A RMS 40Hz-5kHz (not for transient capture) Max conductor size 15mm

TR-2500
TR-2500

Current probe, 10A-500A RMS 40Hz-5kHz (not for transient capture) Max conductor size 50mm

TR-2520
TR-2520

Current probe, 300A - 3000A RMS 40Hz-5kHz (not for transient capture) Max conductor size 72mm

VCP4300
VCP4300

Voltage cable accessory pack Voltage measurement cable for direct connection to standard 120VAC single phase outlet. Includes four (4) jumper cables for various three-phase connections.

TR-2021
TR-2021

Current probe, 1A-30A RMS, 48Hz-10kHz, Max conductor size 20mm Requires cable adaptor CA4300

TR-2019B
TR-2019B

Current probe, 50A-300A RMS 30Hz-5kHz; Max conductor size 52mm Requires cable adaptor CA4300

TR-2022
TR-2022

Current probe, 10A - 1000A RMS 30Hz-5kHz; Max conductor size 54mm Requires cable adaptor CA4300

TR-2023
TR-2023

Current probe, 200A - 3000A RMS 30Hz-5kHz; Max conductor size 65mm Requires cable adaptor CA4300

Flex Probes
Flex Probes

Call factory for sizes and ranges. Requires adapter cable CA4300BNC

COM-RS232
COM-RS232

Isolated communications module RS232 serial interface between PP4300 and PC or printer.

COM-OUA
COM-OUA

USB-FiberOptic Adapter

 

How to Buy
Dranetz products are sold direct from Dranetz, as well as via Sales Reps and Distributors worldwide.
Buy now!
Not ready to buy? Get more info.
Try it before you buy it
Make sure you are buying the right tool for the job. Schedule a personal Dranetz product demo at your location, at your convenience.
Schedule a Demo