Equipped with 8 independent channels, the 3-phase PowerVisa is the only advanced power monitoring instrument to incorporate a color touch screen into its lightweight design. Automated setups provide instant detection of circuits and configurations, ensuring that the instrument is ready to successfully collect data. Users can select the length and mode of data collection, including troubleshooting, data logging, power quality surveys, energy and load balancing.
The 3-phase PowerVisa power quality analyzer is equipped with 8 independent channels and a color touchscreen. Automated setups are included to provide instant detection of circuits and configurations, insuring that the instrument is ready to successfully collect data.
Users can select the length and mode of data collection including troubleshooting, data logging, power quality surveys and energy and load balancing.
See the PowerVisa up close and personal. Schedule your private, personal on-site PowerVisa demonstration today.
Determining the availability and compatibility of facility power prior to the installation of new equipment is simplified using the PowerVisa 440. The instrument incorporates advanced features such as RMS triggers, low/medium frequency transients, and cross triggering between channels used to demonstrate that power mitigation devices such as UPSs are operating properly.
The PowerVisa 440 is an invaluable tool for performing energy surveys, including monitoring energy consumption, usage patterns, peak demands and the activation of large loads to reduce electricity costs.
The PowerVisa 440 has been designed to meet the most advanced power quality standards, including IEEE 1159, IEC 61000-4-30 Class A and EN50160.
The PowerVisa 440’s unique annunciator “report card” provides instant power quality answers in the field. Data is presented in color-coded categories to quickly identify areas of concern, identified in red. Drill down for more detailed information by simply touching the graphical screen.
Training CD for PowewrGuide 4400, PowerXplorer (PX5) and PowerVisa 440
Flash Card Memory provides removable memory of all saved data. The new flash card memory gives you greater capacity for data storage. Available in sizes from 256Mb
Soft carrying case. Rugged cordura nylon carry case holds PX5 / 4400, voltage probes, CTs, and manual. Ideal for field service, industrial applications.
Portable lockable case. Rugged, weatherproof case (NEMA 4x) for harsh environments. Includes multi-conductor voltage measurement and AC power cables. Ideal for utility substation measurements, outdoor jobs.
(CTIC-LPC Cable, for current, is optional)
Reusable shippping container. Protects the analyzer during repeated shipping. Complies with NSTA Project 1A vibration and drop specification. Includes space for accessories. Ideal for 4300s that are shared between offices or carried in trucks and car trunks.
Current probe, 1A-10A RMS 40Hz-5kHz (not for transient capture) Max conductor size 15mm
Current probe, 10A-500A RMS 40Hz-5kHz (not for transient capture) Max conductor size 50mm
Current probe, 300A - 3000A RMS 40Hz-5kHz (not for transient capture) Max conductor size 72mm
Voltage cable accessory pack Voltage measurement cable for direct connection to standard 120VAC single phase outlet. Includes four (4) jumper cables for various three-phase connections.
Current probe, 1A-30A RMS, 48Hz-10kHz, Max conductor size 20mm Requires cable adaptor CA4300
Current probe, 50A-300A RMS 30Hz-5kHz; Max conductor size 52mm Requires cable adaptor CA4300
Current probe, 10A - 1000A RMS 30Hz-5kHz; Max conductor size 54mm Requires cable adaptor CA4300
Current probe, 200A - 3000A RMS 30Hz-5kHz; Max conductor size 65mm Requires cable adaptor CA4300
Call factory for sizes and ranges. Requires adapter cable CA4300BNC
Isolated communications module RS232 serial interface between PP4300 and PC or printer.
USB-FiberOptic Adapter