Power Xplorer Brochure
We are happy to provide this downloadable file for your convenience. Please provide us with some basic information so that we may better address your needs now and in the future. Please enter your email address carefully as this will be where we send the download link. Dranetz respects your privacy. Your contact information will not be sold or rented. Only Dranetz or its authorized sales partners may use this information.
POWERXPLORERPX5 SPECIFICATIONS Measured Parameters Available Languages POWERXPLORER (4) differential inputs, 1-600 Vrms, AC/DC, 0.1% rdg + 0.05% FS, English, French, Italian, German, Spanish, Swedish 256 samples/cycle, 16 bit ADC (4) inputs with CTs 1-6000 Arms CT-dependent, AC/DC, General Specifications 0.1% rdg + CTs, 256 samples/cycle, 16 bit ADC Size (HxWxD): 12" x 2.5" x 8" (30cm x 6.4cm x 20.3cm) 1 MHz High Speed Sampling, 14 bit ADC PX5 Weight: 4.2 pounds (1.9 kg) Frequency Range, 10 mHz resolution, 15-20 Hz, 45-65 Hz Operating Temperature: 0º to 50º C (32º to 122º F) or 350-450 Hz Power Quality Analyzer Storage Temperature: -20º to 55º C (4º to 131º F) Phase Lock Loop - Generator tracking, Standard PQ mode Humidity: 10 to 90% non-condensing System Time Clock-Crystal controlled-1 second resolution Monitoring/Compliance Charger /Battery Eliminator: 90-264 VAC 47-63 Hz IEEE 1159 Display: LCD color touch screen IEC 61000-4-30 Class A Memory options (must have one): 32M-128M removable EN50160 Quality of Supply compact flashcard Current Inrush/ Energization Voltage Fault Recording Optional Accessories Long Term Monitoring w/min/max/avg Current Probes: An extensive selection, including: Continuous Data Logging Model TR-2510A 0-10 A; up to 0.47" conductors Model TR-2500A 10-500 A; up to 1/8" diameter Power Quality Triggers or 2.5" x 0.2"conductors Cycle-by-cycle analysis Model TR-2520A 300-3000 A; up to 2.56" diameter or 256 samples/cycle; 1/2 cycle RMS steps (1) 1.97" x 5.3" (bus bar) L-L, L-N, N-G RMS Variations: Sags/swells/interruptions Model TR-2019B 1-300 A; up to 2.0" conductors RMS Recordings V & I (32 pre-fault, 10K post-fault cycles) (requires 116002-G1 adapter) Waveshape Recordings (32 pre-fault, 10K post-fault cycles) Flexible probes: ranging in current from 30-6000 A, 24", 36", 48" Low and Medium Frequency Transients - V & I Hall Effect Probes for AC/DC applications, 150 A or 1500 A High Frequency Transients - V & I, 3% FS trigger (1) CT Cable Adapter (CA4300LEM) Harmonics Summary Parameters Voltage Cable Accessory Pack (VCP4300) Cross trigger V & I channels Soft Carrying Case (SCC-4300) RMS Event Characterization (IEEE or IEC) Field Replaceable Battery Pack (BP-PX5) Transient Event Characterization (1) External Battery Charger (XBC-PX5) Reusable Shipping Container (RSC-4300) Distortion/Power/Energy Weatherproof Container (NEMA4300) W, VA, VAR, TPF, DPF, Demand, Energy, etc. Lockable Portable Case (LPC-4300) IEEE 1459 Parameters of distorted and unbalanced Portable Field Printer (PFP4300) Harmonics / Interharmonics per IEC 61000-4-7 Communications Interface: THD/Harmonic Spectrum (V,I,W) to 63rd RS232 FiberOptic Adapter (COMM-RS232) TID/Interharmonic Spectrum (V,I) to 63rd USB FiberOptic Adapter (COMM-OUA) Flicker per IEC 61000-4-15 (Pst,Plt,Sliding Plt) LAN-FiberOptic Adapter (COMM-OEA) Crest Factor, K Factor, Transformer Derating Factor, DRAN-VIEW software: Runs under Windows 98, ME, NT, XP Telephone Interference Factor ® NodeLink with download, setups and meter Unbalance (max rms deviation) & sequencing components CD-ROM Training Program 5 User Spec Harmonics or Signaling Frequency (1) PX5-400 samples at 32 samples/cycle, 1 cycle steps at 400 Hz. Vector/Arithmetic/Coincident Parameters Certain parameters measured at 45-65 Hz range only. Sets the new standard for high performance, advanced measurement capabilities 1.800.372.6832 sales@dranetz-bmi.com tel 732.287.3680 • fax 732.248.1834 • 1000 New Durham Road • Edison, New Jersey 08818 USA and enhanced usability PowerXplorer, NodeLink and DRAN-VIEW are trademarks of Dranetz-BMI. ©2003 Dranetz-BMI. All rights reserved. Printed in the United States. Specifications are subject to change without notice. dranetz-bmi.com www.dranetz-bmi.com ™ The PowerXplorer PX5 integrates the most advanced feature set available in a power monitoring instrument, with an easy-to-navigate, color graphical user interface. With high-speed sampling and data capture (1 microsecond/channel), this 8-channel workhorse simultaneously captures and characterizes hundreds of parameters, using a range of standard and customizable operating modes. The unique measurement capabilities of the PowerXplorer include capture of low-medium-high frequency transients through peak, waveshape, rms duration and adaptive high-speed sampling, as well as power measurements to clearly characterize non-sinusoidal and unbalanced systems. DRAN-VIEW is a powerful, yet simple to use tool to visualize and analyze complex power quality events, locate faults, isolate potentially harmful trends, and correlate data Power Quality Surveys and Diagnostics among and across sites. POWERXPLORER A power quality survey is key to pinpointing and diagnosing problems or negative trends and to effectively implement a reliability-centered maintenance program. By PowerXplorer users can select evaluating power quality over a week or longer, baseline conditions and susceptibility to events can be determined so DRAN-VIEW from a multitude of data displays that corrective measures can be implemented. The PowerXplorer such as phasors, waveforms, meters and harmonic spectrums, as well as recording has a built-in event characterizer PX5 that directly supports troubleshooting options that include continuous monitoring or report-by exception, and AC and and the gathering of survey data— for improving power quality and DC measurements for events lasting from a microsecond to an hour. Information equipment reliability, as well as for presentation options range from quality-of-supply, statistical and trending to the matching the requirements and susceptibilities of that equipment to PowerXplorer’s unique annunciator “report card” that provides instant classification the incoming supply. of events. Remote communications are made easy using RS-232, ethernet or USB Fast Transient Capture options to download data for further analysis and reporting using industry-leading The PowerXplorer uses digitized high-speed sampling to capture and analyze DRAN-VIEW software. microsecond-wide transients (Dranetz 658-like and BMI 8800-like). Transients, generated by fast-switching electronics, medical diagnostic equipment, capacitor switching, lightning, transformer energization, and load shifting, are immediately characterized as The 8-channel PowerXplorer PX5-400 provides the full range of advanced impulsive or oscillatory and detailed monitoring and measurement for 400 Hz applications as well as for 50/60 Hz. for further analysis. Capable of Designed specifically for military, shipboard, aerospace and other applications, the capturing the complete power PowerXplorer PX5-400 contains the same advanced feature set as the PowerXplorer, quality spectrum, the PowerXplorer including advanced data characterization, cross-triggering power, and the provides scope-like display of the measurement of distortion parameters. entire transient. Load Distortion and Imbalance Flicker Compliance Monitoring Harmonics Rectified-input power supplies plus other non-linear loads have increased from The activation of arc furnace, large induction machines and other large loads that The PowerXplorer has been designed to meet the most advanced power quality As the sensitivity of power electronics increases, equipment ranging from HVAC 25% of the total U.S. load to over 65% today. These loads draw current only during produce continuous voltage impulses cause a power quality event called flicker. standards, including IEEE 1159, IEC 61000-4-30 Class A and EN50160. A systems, personal computers and copiers to computerized process equipment and part of the waveform, resulting in current distortion, and depending on harmonic Typically, flicker occurs on systems that are weak relative to the amount of power statistical output is produced to quickly verify compliance with international manufacturing systems are susceptible to harmonic pollution. In fact, harmonics impedances, which causes voltage required by the load, combined with quality-of-supply standards and can cause small, almost imperceptible distortion as well. This distortion considerable variations in current benchmark power quality. In an variations in performance that can have a significant derating effect occurring over a short period of instant, the PowerXplorer provides aggregate to effect significant on equipment such as motors and time. The PowerXplorer captures a snapshot of over 13 key long-term damage. Current transformers, causing overheating flicker data per IEC 61000-4-15, parameters, including unbalance, harmonics generated by a source that shorten equipment life. The which can be further evaluated voltage variations and harmonics. can pollute the entire power system PowerXplorer measures the full using Dran-View visualization, without being affected itself. The range of arithmetic, vector and analysis and reporting software. PowerXplorer captures detailed sequencing parameters contained harmonics, interharmonics and in IEEE 1459, to evaluate distortion subharmonics to effectively trouble- and restore balanced loads. shoot the complex problems caused by these events.
Thank you for viewing our pdf. To View the formatted version
download it now