PX5/400 Brochure

We are happy to provide this downloadable file for your convenience. Please provide us with some basic information so that we may better address your needs now and in the future. Please enter your email address carefully as this will be where we send the download link. Dranetz respects your privacy. Your contact information will not be sold or rented. Only Dranetz or its authorized sales partners may use this information.

POWERXPLORERPX5-400 SPECIFICATIONS Measured Parameters Available Languages POWERXPLORER (4) differential inputs, 1-600 Vrms, AC/DC, 0.1% rdg + 0.05% FS, Chinese, English, Finnish, French, German, Italian, Spanish, Swedish 256 samples/cycle (1), 16 bit ADC (4) inputs with CTs 1-6000 Arms CT-dependent, AC/DC, General Specifications 0.1% rdg + CTs, 256 samples/cycle (1), 16 bit ADC Size (HxWxD): 12" x 2.5" x 8" (30cm x 6.4cm x 20.3cm) 1 MHz High Speed Sampling, 14 bit ADC Weight: 4.2 pounds (1.9 kg) PX5-400 Frequency Range, 10 mHz resolution, 15-20 Hz, 45-65 Hz Operating Temperature: 0º to 50º C (32º to 122º F) or 350-450 Hz Power Quality Analyzer Storage Temperature: -20º to 55º C (4º to 131º F) Phase Lock Loop - Generator tracking, Standard PQ mode Humidity: 10 to 90% non-condensing System Time Clock-Crystal controlled-1 second resolution Monitoring/Compliance Charger /Battery Eliminator: 90-264 VAC 47-63 Hz IEEE 1159 Display: LCD color touch screen IEC 61000-4-30 Class A Memory options (must have one): 32M-128M removable MIL-STD-1399 compact flashcard Current Inrush/ Energization Voltage Fault Recording Optional Accessories Long Term Monitoring w/min/max/avg Current Probes: An extensive selection, including: Continuous Data Logging Model TR-2510A 0.1-10 A; up to 0.47" conductors Model TR-2500A 10-500 A; up to 1/8" diameter Power Quality Triggers or 2.5" x 0.2"conductors Cycle-by-cycle analysis Model TR-2520A 300-3000 A; up to 2.56" diameter or 256 samples/cycle; 1/2 cycle RMS steps (1) 1.97" x 5.3" (bus bar) L-L, L-N, N-G RMS Variations: Sags/swells/interruptions Model TR-2019B 1-300 A; up to 2.0" conductors RMS Recordings V & I (32 pre-fault, 10K post-fault cycles) (requires 116002-G1 adapter) Waveshape Recordings (32 pre-fault, 10K post-fault cycles) Flexible probes: ranging in current from 30-6000 A, 24", 36", 48" Low and Medium Frequency Transients - V & I Hall Effect Probes for AC/DC applications, 150 A or 1500 A High Frequency Transients - V & I, 3% FS trigger CT Cable Adapter (CA4300LEM) Harmonics Summary Parameters Voltage Cable Accessory Pack (VCP4300) Cross trigger V & I channels Soft Carrying Case (SCC-4300) RMS Event Characterization (IEEE or IEC) Field Replaceable Battery Pack (BP-PX5) Transient Event Characterization External Battery Charger (XBC-PX5) Reusable Shipping Container (RSC-4300) Distortion/Power/Energy Weather resistant Container (ENCL-HH) W, VA, VAR, TPF, DPF, Demand, Energy, etc. Lockable Portable Case (LPC-4300) IEEE 1459 Parameters of distorted and unbalanced Communications Interface: Harmonics / Interharmonics per IEC 61000-4-7 RS232 FiberOptic Adapter (COMM-RS232) THD/Harmonic Spectrum (V,I,W) to 63rd (2) USB FiberOptic Adapter (COMM-OUA) TID/Interharmonic Spectrum (V,I) to 63rd (2) LAN-FiberOptic Adapter (COMM-OEA) Flicker per IEC 61000-4-15 (Pst,Plt,Sliding Plt) DRAN-VIEW software: Runs under Windows 98, ME, NT, XP Crest Factor, K Factor, Transformer Derating Factor, ® NodeLink with download, setups and meter Telephone Interference Factor CD-ROM Training Program Unbalance (max rms deviation) & sequencing components (1) PX5-400 samples at 32 samples/cycle, 1 cycle steps at 400 Hz. 5 User Spec Harmonics or Signaling Frequency Certain parameters measured at 45-65 Hz range only. Vector/Arithmetic/Coincident Parameters (2) Maximum harmonics to 16th at 400 Hz. State-of-the-art monitoring of 50/60 and 400 Hertz systems 1.800.372.6832 sales@dranetz-bmi.com tel 732.287.3680 • fax 732.248.1834 • 1000 New Durham Road • Edison, New Jersey 08818 USA in one instrument PowerXplorer, NodeLink and DRAN-VIEW are trademarks of Dranetz-BMI. ©2004 Dranetz-BMI. All rights reserved. Printed in the United States. Specifications are subject to change without notice. dranetz-bmi.com www.dranetz-bmi.com The PowerXplorer® PX5-400 was designed specifically for measuring and monitoring power on both 50/60 and 400 Hz power systems on ships, aircraft, submarines, and the testing of equipment used on such. This unique instrument integrates the most advanced feature set available in a power monitoring instrument, with automated setups and an easy-to-navigate, color graphical user interface. With high-speed sampling and data capture (down to 1 microsecond/channel), this 8-channel workhorse simultaneously captures and characterizes thousands of parameters, using a range of standard and customizable operating modes. The PowerXplorer PX5-400 collects data at 256 samples/cycle/channel, is designed for both AC and DC applications, and meets MIL-STD-1399, IEEE 1159, IEC 61000-4-30 and EN50160 standards. Visualization and reporting options using DRAN-VIEW Mil Standard 1399 Testing This interface standard for shipboard systems is the approved testing protocol for POWERXPLORER naval sea standards and all relevant departments within the US DOD. The electric Data can be viewed in real time using scope mode, meter power system serves a variety of user equipment including aircraft elevators, mode, event mode, harmonics spectrum or phasor diagrams. communication systems, weapon systems and computers. The testing protocol is used to verify compatibility with a Data is captured on a memory card for analysis, trending, prescribed list of characteristics and tolerances including transients, sags visualization and reporting using industry-leading DRAN-VIEW® PX5-400 and spikes, unbalance, frequency tolerances and harmonics. software. DRAN-VIEW makes it simple to trend events, correlate data, analyze Recommended testing apparatus – a voltmeter, frequency meter, worst-case scenarios, see frequency fluctuations, generate custom reports, and oscilloscope, harmonics meter, and understand complex issues such as transients and harmonics. current transformers – can all be replaced with one instrument, the PowerXplorer PX5-400. Power Measurement Equipment being used in these applications must be tested in all operating modes, including 400 Hz, to ensure that critical test and operational equipment fits with the power supply. The PowerXplorer PX5-400 collects a range of parameters – from load-related factors such as watts, VA, VAR, frequency instability, power factor and load excursions – to power quality information including sags, swells, transients and harmonics. Users can select the length and mode of data collection, including troubleshooting, data A range of current probes can be selected to fit your needs, from standard clamp-ons to flexible CTs and Hall logging, power quality surveys, current effect probes for DC monitoring. energy and load balancing. Troubleshooting Fast Transient Capture Power Quality Diagnostics Equipment Testing The PowerXplorer PX5-400’s unique annunciator “report card” provides instant The PowerXplorer PX5-400 uses digitized high-speed sampling to capture and The PowerXplorer PX5-400 has a built-in event characterizer that labels events to Evaluating and testing the performance of military components and computerized power quality answers in the field. A wide range of power monitoring data is analyze microsecond-wide transients (Dranetz 658-like and BMI 8800-like). directly support troubleshooting and the gathering of survey data – for improving systems under true operating conditions – 400 Hz or other – is key to ensuring a collected, analyzed and tabulated in color-coded categories to quickly identify areas Transients, generated by fast-switching electronics, computer systems, aircraft power quality and equipment reliability, as well as for matching the requirements successful mission. The PowerXplorer PX5-400 incorporates advanced features of concern, which are identified in components, and load transfer are and susceptibilities of that such as RMS triggers, advanced red. Drill down for more detailed immediately characterized as equipment to the incoming supply. transient capture, and cross information by simply touching the impulsive or oscillatory and detailed Plus, the PowerXplorer PX5-400 triggering between channels to intuitive touch screen to locate the for further analysis. The captures detailed harmonics, ensure that all equipment is source and pinpoint the root cause PowerXplorer PX5-400 delivers a interharmonics and subharmonics working properly. Plus, real time of power quality disturbances. full profile, with events time to effectively troubleshoot the reading observing during testing, stamped to the millisecond of the complex problems caused by startup and maintenance enable entire transient, to pinpoint the these events. users to see results and tweak exact source and cause of the event. equipment on-the-fly.

Thank you for viewing our pdf. To View the formatted version download it now

Download Now
How to Buy
Dranetz products are sold direct from Dranetz, as well as via Sales Reps and Distributors worldwide.
Buy now!
Not ready to buy? Get more info.
Try it before you buy it
Make sure you are buying the right tool for the job. Schedule a personal Dranetz product demo at your location, at your convenience.
Schedule a Demo