We are happy to provide this downloadable file for your convenience. Please provide us with some basic information so that we may better address your needs now and in the future. Please enter your email address carefully as this will be where we send the download link. Dranetz respects your privacy. Your contact information will not be sold or rented. Only Dranetz or its authorized sales partners may use this information.

TRIGGERABLE PARAMETERS FOR POWER PLATFORM SERIES EVENT DESCRIPTION RANGE PARAMETER UNITS MESSAGE (Event Occurs When:) Voltage Hi Limit Volts rms 1 to 9,999,000 V HI LIM Measured rms value crosses this limit Voltage Low Limit Volts rms 0.1 to 9,999,000 V LO LIM Measured rms value crosses this limit Voltage Transient Volts Peak 5 to 9,999,000 V TRANS Measured rms value crosses this limit (+ or - high frequency) Voltage THD % 0.5 to 1000 V THD LIMIT Calculated voltage THD crosses this limit Frequency Sensitivity Hz 0.1 to 450 V FREQ SENS Avg over 20 cycles-the measured frequency changes by this amount (+ or -) Current Hi Limit Amps rms 0.1 to 9,999,000 I HI LIM Measured rms value crosses this limit Current Low Limit Amps rms 0.1 to 9,999,000 I LO LIM Measured rms value crosses this limit Current Peak Amps peak 0.1 to 9,999,000 I PEAK Largest most low frequency sample crosses this limit (+ or -) Current THD % 0.5 to 1000 I THD LIMIT Calculated current THD crosses this limit Current Transient Amps peak 0.1 to 9,999,000 I TRANS Measured peak value crosses this limit (+ or - high frequency) Watts HI Limit Watts 0.1 to 9,999,000 WATTS LIM Calculated value crosses this limit VA HI Limit Volt-Amps 0.1 to 9,999,000 VA LIM Calculated value crosses this limit VAR HI Limit Volt-Amps Reactive0.1 to 9,999,000 VAR LIM Calculated value crosses this limit Power Factor Low Limit None 0.1 to 1.0 PF LO LIM Calculated value crosses this limit Volt Sensitivity Measured value changes by this amount Out Of Limits Volts rms 0.5 to 9,999,000 V SENS OUT while outside the hi and lo limits Volt Sensitivity Measured value changes by this amount In Limits Volts rms 0.5 to 9,999,000 V SENS IN while inside the hi and lo limits Current Sensitivity Measured value changes by this amount Out Of Limits Amps rms 0.1 to 9,999,000 I SENS OUT while outside the hi and lo limits Current Sensitivity Measured value changes by this amount In Limits Amps rms 0.1 to 9,999,000 I SENS IN while inside the hi and lo limits Voltage Transient Voltage transient threshold was crossed 10 consecutive cycles. Threshold is Smart Threshold % 1 to 9,999,000 V TRANS% adjusted up by this % and will adjust back down when signal clears up Current Transient Current transient threshold was crossed 10 consecutive cycles. Threshold is Smart Threshold % 1 to 9,999,000 I TRANS% adjusted up by this % and will adjust back down when signal clears up nTH Voltage Harmonic % 0.1 to 1000 nTH V HARM% User selected voltage harmonic crosses this limit nTH Current Harmonic % 0.1 to 1000 nTH I HARM% User selected voltage harmonic crosses this limit Revised:12/20/00

Thank you for viewing our pdf. To View the formatted version download it now

Download Now
How to Buy
Dranetz products are sold direct from Dranetz, as well as via Sales Reps and Distributors worldwide.
Buy now!
Not ready to buy? Get more info.
Try it before you buy it
Make sure you are buying the right tool for the job. Schedule a personal Dranetz product demo at your location, at your convenience.
Schedule a Demo