Power 1000 Brochure
We are happy to provide this downloadable file for your convenience. Please provide us with some basic information so that we may better address your needs now and in the future. Please enter your email address carefully as this will be where we send the download link. Dranetz respects your privacy. Your contact information will not be sold or rented. Only Dranetz or its authorized sales partners may use this information.
POWER 1000 Universal Power Measuring Instrument for all Electrical Systems • Complete power analysis with simultaneous measurement of all relevant electric supply quantities • Power and energy analysis in power supply systems, as well as at the outputs of frequency converters • Harmonic analysis up to the 50th harmonic including sub- harmonics • Flicker analysis in accordance with EN 61000-4-15 • 8 isolated measuring circuits (4 voltage and 4 current), 100 kHz sampling rate per measuring circuit • Color touch-screen display, 5½", ¼ VGA • Storage of measurement data / settings to plug-in CF memory card or USB memory stick • Transient measurements, 1300vpk as short as 10usec • USB interfaces for PC, external printer/memory/keyboard • Ethernet TCP/IP with integrated web server for remote control and read-out • 4 digital status inputs for indicating consumer operating states • 4 digital control inputs for synchronizing the measuring interval, and for use as meter inputs • 1 relay output for alarms • Internal rechargeable battery with charging controller for power failures • Worldwide use is made possible with a broad range variable power pack (85 to 250 V AC/DC) The POWER 1000 is suitable for broadband Building Services and Operations measurement of electrical quantities in DC systems, Technology as well as single and 3-phase AC systems with any • Acquisition and recording of mains power load and line frequencies of up to 1000 Hz. Even in anomalies for the clarification of interference in systems with variable frequency – at frequency the electrical installation and at power consumers converter outputs –the POWER 1000 is first choice, • Recording and analysis of start-up and operating for a wide range of applications: performance of standby generating plants • Measuring and recording of characteristic Energy Technology electrical quantities for dimensioning static VAR • Measurement in low and medium-voltage* compensators, and testing it for correct systems including features for evaluating power functioning quality indices • Load and energy consumption measurements in • Measurement and recording of electrical electrical distribution systems or at operating operating parameters for wind turbine generator equipment for the detection of critical operating systems together with wind speed* states or potential energy cost-savings • Measurement and recording of electrical operating parameters for photovoltaic energy Drive Technology systems together with light intensity* • Power measurements at electrical motors with simultaneous recording of mechanical quantities Electrical Engineering such as RPM, torque, pump pressure or flow rate* • EMC testing of electrical devices and systems, including harmonics and flicker • Determination of characteristic motor values during operation with a frequency converter • Measurement of static and dynamic alternating and direct current quantities at • Vehicle and Aircraft Manufacturing, Shipbuilding electrical/electronic products in R&D, • Measurements at generators and power manufacturing, the test lab and for service consumers in DC automotive electrical systems applications • Power and harmonics measurements in locomotives and railway electrical systems • Power and harmonics measurements for onboard * requires additional transducer electrical systems in aircraft and ships Symbol Measured Quantity Unit of Chan Chan4 Sum Measure 1-2-3 1-3 Ux L-N voltage, RMS value V X X X UΔx L-L voltage, RMS value V X X Ix Phase current, RMS value A X X X Px Active power W X X X Sx Apparent power VA X X X Qx Reactive power var X X X Dx Distortion power var X X X Qcx Compensation power for reaching setpoint of cosφ var X X X WP+x Active energy import Wh X X X WP-x Active energy export Wh X X X WSx Apparent energy VAh X X X WQx Reactive energy varh X X X cosφx Displacement power factor -- X X φx Phase-shift angle °[degrees] X X PFx Power factor (P/S) -- X X X CFUx Voltage crest factor -- X X X CFIx Current crest factor -- X X X fx Voltage frequency Hz X X ux(t) Voltage waveshape V X X ix(t) Current waveshape A X X px(t) Active power waveshape W X X AsymU Voltage unbalance of the 3~ system % X SeqU Phase sequence of the 3 voltages 123/321 X FLICKER Pmtx Momentary flicker for voltage X X Ux Pstx Short-term flicker (10 min.) for voltage X X Ux Pltx Long-term flicker (2 h) for voltage X X Ux HARMONIC DISTORTION Vx THD, Vx THDG, Total, Group total, and Subgroup total harmonic distortion for X % Vx THDS voltage Vx PWHD Partial weighted harmonic distortion for V x within an adjustable X X % range from hmin to hmax Vx H0, Vx H1, Voltage of DC component, Fundamental, and harmonic group X X V, % Vx H2 …V x H50 for Ix (absolute and relative to VxH1) Vx HG1 …Vx HG50, Voltage of harmonic group and subgroup X X V, % Vx HS1 …Vx HS50, (absolute and relative to VxH1) Vx IG1 …Vx IG49 Voltage of inter-harmonic group and subgroup X X V, % Vx IS1 …Vx IS49 (absolute and relative to VxG1) Ix THD, Ix THDG, Total, Group total, and Subgroup total harmonic distortion for X X % Ix THDS current Ix PWHD Partial weighted harmonic distortion for Ix within an adjustable X X % range from hmin to hmax Ix H0, Ix H1, Current of DC component, Fundamental, and harmonic group X X A, % Ix H2 …Ix H50 for Ix (absolute and relative to IxH1) Ix HG1 …Ix HG50, Current of harmonic group and subgroup X X A, % Ix HS1 …Ix HS50, (absolute and relative to IxH1) Ix IG1 …Ix IG49 Current of inter-harmonic group and subgroup X X A, % Ix IS1 …Ix IS49 (absolute and relative to IxG1) Px H0,Px H1, DC, Fundamental, h2 ... h50 power component of Px (absolute X X W, % Px H2 …Px H50 and relative to PxH1) X X ∏ Ux H0 …∏Ux H50 Phase angle of harmonic h0 ... h50 for Ux to fundamental °[degrees] voltage UxH1 X X ∏ Ix H0 …∏Ix H50 Phase angle of harmonic h0 ... h50 for Ix to fundamental °[degrees] current IxH1 Characteristic Specification Notes VOLTAGE INPUTS Quantity 4 Mutually isolated Connection Two 4 mm safety sockets each Red (high), black (low) Connection options Single phase, 2-phase (split-phase), 3-phase wye or delta Input impedance 4 M // 5 pF Coupling AC / AC+DC Input range 0 to 150 V / 300 V / 600 V / 900 V Manually selectable Scaling factors 0.001 to 99,999 V/V Individually adjustable for each input Overload withstand Continuous: 1200 VRMS, transient (1.2/50 μs): 6000 Vpeak CURRENT INPUTS For clamp-on probes or shunts Quantity 4 Mutually isolated Connection Two 4 mm safety sockets each Red (high), black (low) Connection options 3xL + N, 3xL, 2xL + N (two-wattmeter method) L1, L2, L3, N (calculated) Input Impedance 1 M // 5 pF Coupling AC / AC+DC Input range 0 to 300 mV / 3 V Manually selectable Scaling factors 0 / 0.001 to 99,999 V/V Individually adjustable for each input Overload withstand Continuous: 400 VRMS, transient (1.2/50 μs):1000 Vpeak VOLTAGE and CURRENT Sampling rate 100 kS/s Simultaneously at each Sampling resolution 16 bit Frequency range DC, 15 Hz to 10 kHz Crosstalk -60 dB between voltage channels, attenuation -95 dB between voltage and current DIGITAL INPUTS Quantity 4 Floating, common reference point Functions Display and record state, count pulses Connection Plug-in connectors with screw terminals DC input signal Low: <3V, High: 5 to 24V Overload withstand 30V, continuous CONTROL INPUTS Quantity 4 Functions Start/Stop recording; Synch demand interval Connection Plug-in connectors with screw terminals DC input signal Low: <2V, High: 4 to 5V Overload withstand 6V, continuous ALARM OUTPUT Function Floating relay contact for Limit exceed, 30V @ 1A max Accuracy Range 15-65-Hz DC – 1000Hz 1-10KHZ 1.0 to 900 V rms +/- 0.2% rdg +/- 0.1% range +/- 0.4% rdg +/- 0.2% range +/- 1% rdg RMS VOLTAGE +/- 0.5% rng 0.0 to 3.00 A rms +/- 0.2% rdg +/- 0.1% range +/- 0.4% rdg +/- 0.2% range +/- 1% rdg +/- RMS CURRENT 0.5% rng V & I dependent +/- 0.5% rdg +/- 5% range POWER 1.0 to 900 V rms +/- 3% rdg +/- 0.1% range +/- 5% rdg +/- 0.2% range V HARMONIC – Absolute V Phase Angle -180* to + 180* 1 deg * Harm# 2 deg * Harm# 0 to 200% 2% 4% VTHD 0.0 to 3.00 A rms +/- 0.2% rdg +/- 0.1% range +/- 0.4% rdg +/- 0.2% range I HARMONIC – Absolute I Phase Angle -180* to + 180* 1 deg x Harm# 2 deg x Harm# 0 to 200% 2% 4% I THD FREQUENCY 15 To 99.9 +/- 0.05% rdg +/- 1 digits 100 to 999 +/- 0.1% rdg +/- 2 digits 1KHz to 10Khz +/- 0.2% rdg +/- 3 digits > 10KHz +/- 0.5% rdg +/- 5 digits Display: Color LCD touch screen, ¼ VGA, 320x240 pixels, CCFL backlight Memory: Internal 50M Flash, plug-in Compact Flash card, plug-in USB data storage media Time Clock: 10msec resolution, max 5 sec per month drift Power Supply: 85-250VAC/DC, 45-400Hz, 40W max, 20 minute backup battery (after 2 hr charging) USB Host: USB 1.1 Interface for recording data and setups, and installation of firmware updates Slave: USB 1.1 Interface for remote control of instrument, and transfer of measurement and setup files Ethernet: 10/100 Base T (RJ45), Protocols: TCP/IP, HTTP, FTP Operating Range: 0 to 40 deg C within spec, -10 to 50 deg C with reduced accuracy; max 95%RH w/o condensation for 0 to 25deg C, max 75% 25 to 40 deg C 2000 M altitude Physical Dimensions: 290 x 245 x 140 mm, 2.4 kg without accessories Mechanical Protection: Housing IP30, Terminals IP 20 Electrical Safety: Safety Class I per IEC 61010-1, Measuring: 600V CAT IV, 1000V CAT III Electromagnetic Compatibility: Per EN 61236, compiles with EC directive 89/336 STANDARD ACCESSORIES: • (1) set of cables for voltage measurement inputs including 4 pairs of measurement cables (length: approx. 2 m) with test probe and plug-on alligator clips • (3) short measurement cables with 4 mm safety plugs (stackable) for bridging measurement inputs • (1) power cable with protective contact plug and inlet plug • (1) USB-A interface cable • (1) Ethernet interface cable • (1) stylus pen • (1) printed copy of operating instructions • (1) CD ROM with latest operating instructions, technical data sheet and respectively measuring notes • (1) lockable carrying case for instrument and accessories OPTIONAL ACCESSORIES: • Current clamp-on probes (1-1000A), flexible probes (1 to 20KA); shunts 20mA to 16A) • DranView software 1.800.372.6832 sales@dranetz-bmi.com tel 732.287.3680 : fax 732.248.1834 1000 New Durham Road, Edison, New Jersey 08818 USA © 2009 Dranetz-BMI. All rights reserved. www.dranetz-bmi.com Printed in United States. Specifications are subject to change without notice. Power1KI Rev 19-Nov-09
Thank you for viewing our pdf. To View the formatted version
download it now