MeasuringPad User Manual

We are happy to provide this downloadable file for your convenience. Please provide us with some basic information so that we may better address your needs now and in the future. Please enter your email address carefully as this will be where we send the download link. Dranetz respects your privacy. Your contact information will not be sold or rented. Only Dranetz or its authorized sales partners may use this information.

TM MeasuringPad MP USER’S GUIDE DRANETZ-BMI 1000 New Durham Road Edison, NJ 08818 WARNING Death, serious injury, or fire hazard could result from improper connection of this instrument. Read and understand this manual before connecting this instrument. Follow all installation and operating instructions while using this instrument. Connection of this instrument to an electrical system must be performed in compliance with the National Electrical Code (ANSI/NFPA 70-2005) of USA and any additional safety requirements applicable to your installation. Installation, operation, and maintenance of this instrument must be performed by qualified personnel only. The National Electrical Code defines a qualified person as “one who has the skills and knowledge related to the construction and operation of the electrical equipment and installations, and who has received safety training on the hazards involved.” Qualified personnel who work on or near exposed energized electrical conductors must follow applicable safety related work practices and procedures including appropriate personal protective equipment in compliance with the Standard for Electrical Safety Requirements for Employee Workplaces (ANSI/NFPA 70E-2004) of USA and any additional workplace safety requirements applicable to your installation. Published by Dranetz-BMI 1000 New Durham Road Edison, NJ 08818 USA Telephone: 1-800-372-6832 or 732-287-3680 Fax: 732-248-1834 Web site: www.dranetz-bmi.com Copyright © 2005 Dranetz-BMI All rights reserved. No part of this book may be reproduced, stored in a retrieval system, or transcribed in any form or by any means—electronic, mechanical, photocopying, recording, or otherwise—without prior written permission from the publisher, Dranetz-BMI, Edison, NJ 08818. Printed in the United States of America. P/N UG-MP Rev. B ii ADVERTENCIA Una conexión incorrecta de este instrumento puede producir la muerte, lesiones graves y riesgo de incendio. Lea y entienda este manual antes de conectar. Observe todas las instrucciones de instalación y operación durante el uso de este instrumento. La conexión de este instrumento a un sistema eléctrico se debe realizar en conformidad con el Código Eléctrico Nacional (ANSI/NFPA 70-2005) de los E.E.U.U., además de cualquier otra norma de seguridad correspondiente a su establecimiento. La instalación, operación y mantenimiento de este instrumento debe ser realizada por personal calificado solamente. El Código Eléctrico Nacional define a una persona calificada como "una que esté familiarizada con la construcción y operación del equipo y con los riesgos involucrados." El personal cualificado que trabaja encendido o acerca a los conductores eléctricos energizados expuestos debe seguir prácticas y procedimientos relacionados seguridad aplicable del trabajo incluyendo el equipo protector personal apropiado en conformidad con el estándar para los requisitos de seguridad eléctricos para los lugares de trabajo del empleado (ANSI/NFPA 70E-2004) de los E.E.U.U. y cualquier requisito de seguridad adicional del lugar de trabajo aplicable a su instalación. AVERTISSEMENT Si l'instrument est mal connecté, la mort, des blessures graves, ou un danger d'incendie peuvent s'en suivre. Lisez attentivement ce manuel avant de connecter l'instrument. Lorsque vous utilisez l'instrument, suivez toutes les instructions d'installation et de service. Cet instrument doit être connecté conformément au National Electrical Code (ANSI/NFPA 70-2005) des Etats-Unis et à toutes les exigences de sécurité applicables à votre installation. Cet instrument doit être installé, utilisé et entretenu uniquement par un personnel qualifié. Selon le National Electrical Code, une personne est qualifiée si "elle connaît bien la construction et l'utilisation de l'équipement, ainsi que les dangers que cela implique". Le personnel qualifié qui travaillent dessus ou s'approchent des conducteurs électriques activés exposés doit suivre des pratiques en matière et des procédures reliées par sûreté applicable de travail comprenant le matériel de protection personnel approprié conformément à la norme pour des conditions de sûreté électriques pour les lieux de travail des employés (ANSI/NFPA 70E-2004) des Etats-Unis et toutes les conditions de sûreté additionnelles de lieu de travail applicables à votre installation. WARNUNG Der falsche Anschluß dieses Gerätes kann Tod, schwere Verletzungen oder Feuer verursachen. Bevor Sie dieses Instrument anschließen, müssen Sie die Anleitung lesen und verstanden haben. Bei der Verwendung dieses Instruments müssen alle Installation- und Betriebsanweisungen beachtet werden. Der Anschluß dieses Instruments muß in Übereinstimmung mit den nationalen Bestimmungen für Elektrizität (ANSI/NFPA 70-2005) der Vereinigten Staaten, sowie allen weiteren, in Ihrem Fall anwendbaren Sicherheitsbestimmungen, vorgenommen werden. Installation, Betrieb und Wartung dieses Instruments dürfen nur von Fachpersonal durchgeführt werden. In dem nationalen Bestimmungen für Elektrizität wird ein Fachmann als eine Person bezeichnet, welche "mit der Bauweise und dem Betrieb des Gerätes sowie den dazugehörigen Gefahren vertraut ist." Qualifiziertes Personal, das an bearbeiten oder herausgestellte angezogene elektrische Leiter sich nähern, muß anwendbare Sicherheit bezogener Arbeit Praxis und Verfahren einschließlich passende persönliche schützende Ausrüstung gemäß dem Standard für elektrische Sicherheitsauflagen für Angestellt- Arbeitsplätze (ANSI/NFPA 70E-2004) der Vereinigten Staaten und alle zusätzlichen Arbeitsplatzsicherheitsauflagen folgen, die auf Ihre Installation anwendbar sind. iii Safety Summary WARNING statements inform the user that certain conditions or practices could result Definitions in loss of life or physical harm. CAUTION statements identify conditions or practices that could harm the MP, its data, other equipment, or property. NOTE statements call attention to specific information. The following International Electrotechnical Commission (IEC) symbols are marked Symbols on the top and rear panel in the immediate vicinity of the referenced terminal or device: Caution, refer to accompanying documents (this manual). ! Direct current (DC) operation of the terminal or device. Power Switch Las ADVERTENCIAS informan al usuario de ciertas condiciones o prácticas que Definiciones podrían producir lesiones mortales o daño físico. Las PRECAUCIONES identifican condiciones o prácticas que podrían dañar la MP, sus datos, otros equipos o propiedad. Las NOTAS llaman la atención hacia la información específica. Los siguientes símbolos de la Comisión Internacional Electrotécnica (IEC) aparecen Símbolos marcados en el panel superior y el posterior inmediatos al terminal o dispositivo en referencia: Precaución, consulte los documentos adjuntos (este manual). ! Operación de corriente continua (CC) del terminal o dispositivo. Interruptor de encendido Continued on next page iv Safety Summary, Continued Les messages d’AVERTISSEMENT préviennent l’utilisateur que certaines conditions Définitions ou pratiques pourraient entraîner la mort ou des lésions corporelles. Les messages de MISE EN GARDE signalent des conditions ou pratiques susceptibles d’endommager “MP”, ses données, d’autres équipements ou biens matériels. Les messages NOTA attirent l’attention sur certains renseignements spécifiques. Les symboles suivants de la Commission électrotechnique internationale (CEI) figurent Symboles sur le panneau arrière supérieur situé à proximité du terminal ou de l’unité cité: Mise en garde, consultez les documents d’accompagnement (ce manual). ! Fonctionnement du terminal ou de l’unité en courant continu (CC). Interrupteur de tension WARNUNGEN informieren den Benutzer darüber, daß bestimmte Bedingungen oder Definitionen Vorgehensweisen körperliche oder tödliche Verletzungen zur Folge haben können. VORSICHTSHINWEISE kennzeichnen Bedingungen oder Vorgehensweisen, die zu einer Beschädigung von MP, seiner Daten oder anderer Geräte bzw. von Eigentum führen können. HINWEISE machen auf bestimmte Informationen aufmerksam. Symbole Die folgenden Symbole der Internationalen Elektrotechnischen Kommission (International Electrotechnical Commission; IEC) befinden sich auf der Abdeck- und Seitenplatte unmittelbar am betreffenden Terminal oder Gerät. Vorsichtshinweis, siehe Begleitdokumente (dieses Handbuch). ! Gleichstrombetrieb im Terminal oder Gerät. Netzschalter Continued on next page v Safety Summary, Continued The following safety precautions must be followed whenever any type of voltage or Safety precautions current connection is being made to the MP. • Wear proper Personal Protective Equipment, including safety glasses and insulated gloves when making connections to power circuits. • Hands, shoes and floor must be dry when making any connection to a power line. • Before each use, inspect all cables for breaks or cracks in the insulation. Replace immediately if defective. • Set the MP power switch to Off. Before connecting to electric circuits to be monitored, open their related circuit breakers or disconnects. DO NOT install any connection of the MP to live power lines. • Pods should be connected first to the MP, then connect to the circuit to be monitored. • If the equipment is used in a manner not specified in this user’s guide, the protection provided by the equipment may be impaired. These safety precautions are repeated where appropriate throughout this manual. vi Statements and Notices All products of Dranetz-BMI are warranted to the original purchaser against defective Statement of warranty material and workmanship for a period of one year from the date of delivery. Dranetz- BMI will repair or replace, at its option, all defective equipment that is returned, freight prepaid, during the warranty period. There will be no charge for repair provided there is no evidence that the equipment has been mishandled or abused. This warranty shall not apply to any defects resulting from improper or inadequate maintenance, buyer- supplied hardware/software interfacing, unauthorized modification or misuse of the equipment, operation outside of environmental specifications, or improper site preparation or maintenance. The information in this manual has been reviewed and is believed to be entirely Statement of reliability reliable, however, no responsibility is assumed for any inaccuracies. All material is for informational purposes only and is subject to change without prior notice. This device has been tested and found to comply with the limits for a Class A digital Notice regarding FCC compliance device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his/her own expense. Notice regarding This publication contains information proprietary to Dranetz-BMI. By accepting and proprietary using this manual, you agree that the information contained herein will be used solely rights for the purpose of operating equipment of Dranetz-BMI. Continued on next page vii Statements and Notices, Continued This publication is protected under the Copyright laws of the United States, Title 17 et Copyright seq. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form, by any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior written consent of Dranetz-BMI, 1000 New Durham Road, Edison, NJ 08818. Copyright © 2005 Dranetz-BMI All Rights Reserved. Printed in the United States of America. MeasuringPad is a trademark of Dranetz-BMI. Trademarks viii Table of Contents Safety Summary .................................................................................................................... iv Statements and Notices.......................................................................................................... vii CHAPTER 1 - Getting Started Overview ............................................................................................................................... 1-1 Unpacking the MP................................................................................................................. 1-3 Standard Accessories............................................................................................................. 1-4 MP Controls, Indicators, and Connectors.............................................................................. 1-5 Top and Side Views ........................................................................................................ 1-6 Front View ...................................................................................................................... 1-7 Bottom View................................................................................................................... 1-8 Rear View ....................................................................................................................... 1-9 Upgrading Firmware from a Data Card................................................................................. 1-10 MP Features........................................................................................................................... 1-12 Basic Operation ..................................................................................................................... 1-14 Power-on Sequence......................................................................................................... 1-15 Home Screen Icons ......................................................................................................... 1-16 CHAPTER 2 - Input Pod Connection Overview ............................................................................................................................... 2-1 Types of Measurement Pods.................................................................................................. 2-4 Pod Connections .................................................................................................................... 2-5 Connecting the Pods to the Cable Panel................................................................................ 2-11 CHAPTER 3 - Start/Setup Operations Overview ............................................................................................................................... 3-1 Section A -Setup Wizard.............................................................................................................. 3-3 Overview ............................................................................................................................... 3-3 Global Setting Menu.............................................................................................................. 3-4 Input Configuration ............................................................................................................... 3-6 Calculates Configuration ....................................................................................................... 3-15 Violation Configuration......................................................................................................... 3-16 Site Name/Memory Card....................................................................................................... 3-17 Section B -Monitor using Present Setup ...................................................................................... 3-21 Overview ............................................................................................................................... 3-21 Turning Monitoring On/Off................................................................................................... 3-21 Monitoring at a Specified Time and Date ............................................................................. 3-25 Section C -Load Setup from Card................................................................................................ 3-29 Section D -Load Data from Card ................................................................................................. 3-30 Overview ............................................................................................................................... 3-30 Loading Data from Card........................................................................................................ 3-30 Card Error Messages ............................................................................................................. 3-31 ix Table of Contents, Continued CHAPTER 4 - View Real Time Data Overview ............................................................................................................................... 4-1 Section A -Scope Mode ............................................................................................................... 4-2 Overview ............................................................................................................................... 4-2 Turn Channels On/Off........................................................................................................... 4-3 Edit Plot ................................................................................................................................. 4-4 Scope Options ....................................................................................................................... 4-5 Section B -Meter Mode................................................................................................................ 4-6 Overview ............................................................................................................................... 4-6 Physical Inputs....................................................................................................................... 4-7 Calculates............................................................................................................................... 4-8 Thermocouple Function......................................................................................................... 4-9 Section C -DFT (Discrete Fourier Transform)............................................................................. 4-10 Overview ............................................................................................................................... 4-10 DFT Spectrum Graph ............................................................................................................ 4-11 Graph Details......................................................................................................................... 4-12 Frequency Spectrum List....................................................................................................... 4-13 Section D -Graph.......................................................................................................................... 4-14 Overview ............................................................................................................................... 4-14 Graph Display........................................................................................................................ 4-14 CHAPTER 5 - View Recorded Data Overview ............................................................................................................................... 5-1 Section A -Reports ....................................................................................................................... 5-3 Overview ............................................................................................................................... 5-3 Record Data Display.............................................................................................................. 5-4 Record List ............................................................................................................................ 5-5 Record Detail......................................................................................................................... 5-6 Export Data File..................................................................................................................... 5-9 Plotted Parameter................................................................................................................... 5-10 Section B -Trend .......................................................................................................................... 5-12 Overview ............................................................................................................................... 5-12 Trend Display ........................................................................................................................ 5-13 Section C -Status.......................................................................................................................... 5-14 Overview ............................................................................................................................... 5-14 Status Display & Operation................................................................................................... 5-15 CHAPTER 6 - Instrument Settings Overview ............................................................................................................................... 6-1 Access Instrument Settings Menu ......................................................................................... 6-2 Time and Date Settings.......................................................................................................... 6-3 x Table of Contents, Continued Select Language..................................................................................................................... 6-5 Set Display Preferences......................................................................................................... 6-6 Touch Screen Calibration ...................................................................................................... 6-9 Turn Threshold Beeper On/Off ............................................................................................. 6-11 Format Data Card .................................................................................................................. 6-12 Edit Dictionary ...................................................................................................................... 6-14 Reset to Factory Configuration.............................................................................................. 6-14 APPENDIX A - Optional Accessories Overview ............................................................................................................................... A-1 Hardware Accessories List & Descriptions........................................................................... A-2 APPENDIX B - Technical Specifications Overview ............................................................................................................................... B-1 General................................................................................................................................... B-2 Interfaces ............................................................................................................................... B-3 Input Parameters .................................................................................................................... B-4 Calculated Parameters ........................................................................................................... B-6 APPENDIX C - Battery Specifications and Replacement Procedure Overview ............................................................................................................................... C-1 Battery Specifications............................................................................................................ C-2 Battery Safety Precautions..................................................................................................... C-3 External Battery Charger....................................................................................................... C-4 Battery Pack Replacement..................................................................................................... C-6 APPENDIX D - User Replaceable Parts List APPENDIX E - MP Menu Structure xi Dranetz-BMI MeasuringPadTM MP xii C H A P T E R 1 Getting Started Overview TM The Dranetz-BMI MeasuringPad MP is a portable, hand-held, sixteen analog and MeasuringPad description eight digital channel data acquisition instrument. It is designed with a color liquid crystal display (LCD) 1/4 VGA, using touch screen technology. It can monitor, record and display data of up to 16 differential analog inputs and up to 8 logic-level digital inputs simultaneously. MP is also capable of processing Calculates, which are math functions performed on one or more channels combined. These calculated pseudo channels are formed from analog input channels and/or from other calculated channels. Unless otherwise indicated, “channel” references to an analog, digital, or calculated channel. Transducers and sensors monitor machines or process equipment can connect to MP through external Pods. The Pods easily plug in to the connector pannel of the instrument and are available as optional accessories. MP automatically detects input signals from a DC/AC 600V Voltage Pod, DC/AC 300V Voltage Pod, DC/AC 30V Voltage Pod, DC/AC 20MA Current Pod, 1.5VAC RMS Universal Current Clamp Pod, and/or Thermocouple Pod. A maximum of four Pods per instrument are supported. Each Pod has 4 analog channels and 2 digital channels which can be enabled to send data to the instrument. ® At the touch of a button, MP can export and store data in MS Excel file format for further analysis, graphing, or inclusion in reports. The firmware for MP is contained on internal FLASH memory. It has an operating MP Firmware system capable of performing multiple applications. When an updated version of the firmware is released, the user can upgrade the internal program by putting the latest MP firmware program card in the appropriate slot of the mainframe. See page 1-10 for instructions on how to upgrade the MP firmware from a data card. The MP firmware architecture is designed to collect, monitor and display measurement data from multiple sensor inputs. This provides for a powerful tool for troubleshooting, maintenance, process tuning, fault recording, trend analysis, and much more. This manual contains instructions for operating the Dranetz-BMI MeasuringPad MP. This manual 1-1 Overview, continued The following topics are covered in this chapter. In this chapter Topic See Page Unpacking the MP 1-3 Standard Accessories 1-4 MP Controls, Indicators and Connectors 1-5 Upgrading Firmware from a Data Card 1-10 MP Features 1-12 Basic Operation 1-14 1-2 CH 1/ Getting Started Unpacking the MP For maximum protection against possible shipping damage, the MP has been sealed in Introduction a two-piece, plastic suspension pack, enclosed within a durable shipping carton. After opening the carton, inspect the contents for possible shipping damage and check the carton inventory. Unpack the MP from the carton as follows: Unpacking Step Action 1 Remove any literature inside the top of the carton. 2 Carefully remove the MP from its shipping carton. 3 Remove all accessories inside the carton. Check that all of the standard accessories (see page 1-4) are included. Visually inspect the MP for possible shipping damage. If any damage exists, first notify Shipping damage and file an insurance claim with your carrier or underwriter or both. Then notify inspection Dranetz-BMI Customer Service Department of your intentions to return the unit. DO NOT return the MP without prior instructions from Dranetz-BMI Customer Service Department. Dranetz-BMI Customer Service Department can be reached at 1-800-372- 6832 or 732-287-3680. If the unit must be returned to Dranetz-BMI for service or repair, wrap the unit securely Repacking for return shipment in heavy packaging material and place in a well padded box or crate to prevent damage. Do not return the MP in an unpacked box. Dranetz-BMI will not be responsible for damage incurred during transit due to inadequate packing on your part. Notify Dranetz-BMI Customer Service of your intention to return the unit. Do not Return notice return the unit without prior instructions from Dranetz-BMI. A Return Material Authorization (RMA) will be issued. Dranetz-BMI Customer Service Department can be reached at 1-800-372-6832 or 732-287-3680. 1-3 Standard Accessories Standard Accessories The following table lists the MP's standard accessories. Standard accessories Description Part Number Easel 116038-G1 Carry Strap 116040-G1 AC Adapter MP-ACADP (117029-G2) 32MB CompactFlash Data Card MP-32M *US Power Cord, 125V, 10A USSTDCORD (900744) *European Power Cord, Shielded EUROSTDCORD (115369-G1) *United Kingdom Power Cord, Shielded UKSTDCORD (115368-G2) *Australian Power Cord, Unshielded AUSTDCORD (901347) Notice: Charge Battery 899146 MeasuringPad MP User’s Guide UG-MP *User specified, one standard only. Refer to Appendix A for the list of hardware optional accessories available for use with Optional accessories MP. Refer to Appendix C for the description and replacement of the batteries contained in Batteries MP. Refer to Appendix D for the user replaceable parts. Replaceable parts The recommended calibration interval for this unit is once every 12 months. Calibration We recommend that you return the unit to the factory for calibration. If you decide to do so, first contact the Dranetz-BMI Customer Service Department to obtain an Authorization Number. Telephone: 1-800-372-6832 or 732-287-3680 FAX: 732-248-1834 Fill out the Repair/Service Order form enclosed in the shipping carton and ship it along with the unit to the Dranetz-BMI Repair Department. (If this form is missing, ask the Dranetz-BMI Customer Service Department for a replacement.) 1-4 CH 1/ Getting Started MP Controls, Indicators, and Connectors MP is a self-contained, portable instrument weighing a little over 4 pounds and Dimensions measuring 8" (20.3 cm) deep by 12" (30 cm) wide by 2.5" (6.4 cm) high. This section identifies and describes the controls, indicators, and connectors on all panels of the instrument (shown here with rubber boot installed). Top View Front View Rear View Bottom View SL O T 1 SL O T 2 1-5 MP Controls, Indicators, and Connectors, continued The top view features four input Pod channel connectors. The left side contains the Top and Side views optical interface port. The right side contains the AC adapter input connector. Both sides have rings for attaching the supplied carrying strap. See below for descriptions of the top and side connectors. 1 2 3 4 Parts table Part Function 1 Channel A Input Pod Connector 2 Channel B Input Pod Connector 3 Channel C Input Pod Connector 4 Channel D Input Pod Connector 5 Optical Serial Data Port NOTE: This data port is not activated at this time. 6 AC Adapter/Battery Charger Input Connector 1-6 CH 1/ Getting Started The front view primarily shows the color touch screen LCD. See below for descriptions Front view of the MP front panel. 1 2 Parts table Part Function 1 Mainframe Protective Rubber Boot Enclosure 2 Liquid Crystal Display (LCD). Provides 3.75 x 4.75 inches display consisting of 1/4 VGA size screen of text and graphic information. The color LCD is equipped with touch screen technology, operable using the finger and/or PDA stylus. Touch screen display permits menu selection, alphanumeric data entry, and has a compact fluorescent (CCFL) backlighting that can be turned on for low light level viewing. The following are some basic care instructions for the LCD monitor: • Use and store the unit within the specified temperature and humidity range. The LCD screen may be adversely affected by exposure to high temperature or humidity. Condensation or moisture produced by sudden temperature changes may also damage the LCD screen. Clean any moisture from surface immediately. • Be careful when cleaning or removing stains on the LCD surface. Gently wipe the surface with a soft cloth or cotton pad. Isopropyl alcohol may be used, but make sure that all solvent residue is removed. • Do not apply excessive force to the LCD surface. The LCD screen contains sensitive electronic components that may be damaged due to strong impact. 1-7 MP Controls, Indicators, and Connectors, continued The bottom view features two slots. Either slot can be used to hold the data card. It also Bottom view displays the LED indicators and the On/Off power button. See below for descriptions of the slots, indicators, and button. NOTE: Use only one card slot (one data card) at a time. The additional slot will be used for future communications options. Also, use only Dranetz-BMI supplied Compact Flash data cards. Do not use cards purchased elesewhere. Dranetz-BMI Compact Flash cards have been tested to work properly with the MP. Non-Dranetz-BMI Compact Flash cards may not be compatible with the instrument and cannot be supported by Dranetz-BMI Customer Service in case problems arise. 1 SLOT 1 SLOT 2 2 3 4 5 6 7 Part Function Parts table 1 Slot 1. Holds and connects data card to internal circuitry. Data card works in either Slot 1 or Slot 2. 2 Slot 2. Holds and connects data card to internal circuitry. Data card works in either Slot 1 or Slot 2. NOTE: This additional slot will be used for future options. 3 Data Card Release: Eject data card in Slot 1 or Slot 2 by pushing the appropriate data card release button. 4 Battery Charge Indicator. LED will light steadily while battery is fast charging and blink when fully charged. 5 Status Indicator. LED will light steadily when abnormal condition is detected. The unit is operating normally when light is off. NOTE: Status indicator will light for approximately 3 seconds when unit is turned on. 6 Power Indicator. LED will blink in a heartbeat fashion (once per second) when the unit is operating normally. 7 On/Off Power Button. Push for on, push for off. 1-8 CH 1/ Getting Started The rear view shows the battery compartment and the easel studs to mount the unit to Rear view desired angular position for use on a flat surface or to hang from a panel. 1-9 Upgrading Firmware from a Data Card Upgrading Firmware from a Data Card Users can upgrade the MP internal program by downloading the latest firmware update MP firmware web upgrade release from the web and installing it into the MP internal memory. Refer to the instructions below on how to upgrade the MP firmware. Firmware upgrades for the MP can be downloaded from the Dranetz-BMI website. Log on to www.dranetz-bmi.com for the latest information on MP firmware update releases. The procedure below specifies how to download the latest MP firmware from the web Copy MP firmware and copy it into a data card. program in data card Step Action 1 Locate the latest version of the firmware upgrade (in data file format “hostcode.bin”) from the Dranetz-BMI website www.dranetz-bmi.com. Dranetz-BMI regularly posts the latest information and instructions regarding MP firmware upgrade releases. 2 Format the Compact Flash data card using the Memory Card options in MP. The card must be formatted before it can be written to. Refer to Chapter 3 Start/Setup Operations - Site Name/Memory Card on page 3- 17 for instructions on how to format the data card. NOTE: All data and setups stored in card will be lost when you format the data card. Copy any files that you want to save to a computer first before formatting the card. 3 Insert the Compact Flash data card into the appropriate slot in the computer. If the computer does not accommodate a Compact Flash card in its native format, use a compatible PC card adapter to read/write data into the card. 4 Download and copy the latest version of the MP firmware upgrade program (data file “hostcode.bin”) from the Dranetz-BMI website to the data card. Refer to page 1-11 for instructions on how to install the data card containing the latest firmware upgrade to the MP. 1-10 CH 1/ Getting Started Install data card The procedure below specifies how to install the data card containing the latest to MP firmware upgrade to the MP. Step Action 1 Make sure that the unit is off. If not, press the MP On/Off power button to turn the unit off. 2 Remove the data card from its protective holder and check that the plug end of card is clean and free of any obstruction. NOTE: If plug end of card is dirty, clean with static-free, dry, low pressure air to remove any foreign material causing obstruction of the plug holes. 3 At the bottom of the unit, position the data card with the label facing up and the plug end facing the top slot (Data Card Slot 1). Make sure that there are no other cards in the unit except for the data card. 4 Insert the card fully into the top slot (Data Card Slot 1) until resistance is felt, then press firmly until the card engagement is felt. NOTE: Do not force the card further into the slot if no card engagement is felt. Remove the card and check if there is a foreign object on or in the plug end of the card. Remove any obstruction. Reinsert program card and repeat card engagement. If card cannot be engaged, STOP all further action and call Dranetz-BMI Technical Support at 1-800-372-6832 for assistance. 5 Turn the unit on by pushing the on/off button. The loader should display “Booting from program card”. If not, call Dranetz-BMI Technical Support for assistance. 6 The instrument will prompt the user to verify whether or not to upgrade the firmware. Press Yes and the upgrade procedure will commence. Do not turn the power off nor remove the data card while firmware upgrade is in progress. 7 If no errors were detected, a window displaying “Installation Complete” will pop up. Remove the data card from the unit. 1-11 MP Features MP Features All MP functions described below are operable using a color LCD touch screen Touch screen function technology. Users may use a finger and/or a PDA stylus to apply pressure to the LCD screen to result in touch screen recognition. Touch screen buttons will show visual feedback of contact along with audible feedback when pressed. In order to reduce power consumption, the backlight of the LCD screen times-out after a specified programmable time of no user activity. The backlight reactivates by touching any part of the screen. Scope mode functions as an oscilloscope, displaying real-time waveforms of voltage Scope mode and current for up to ten channels simultaneously, with one second update rate. The number of channels to plot, horizontal and vertical scale division for axis values, and colors of waveform display are user programmable. Users can also adjust the vertical position of the waveform, view trigger updates on screen, and ground out the channel to see where zero would show on the screen for that channel. Meter mode functions display either the dc or ac value of the channels along with other Meter mode calculated parameters. Meter readings are displayed in numerical format using user- specified labels or tag names. The number of active meters are based on user setups. The limits from the setups also control whether the numbers appear as black (within limits) or red (out of limits). DFT displays the frequency components that make up the channel’s signal values of DFT (Discrete Fourier selected analog inputs up to approximately 4kHz. DFT defaults to a graphical spectrum Transform) display, although users have the option to choose between the graph and list form. Graph displays the channel values in a horizontal bar graph as a percent of their full Graph scale value. Users can select up to eight channel bar graphs to display. Users may perform instrument setup by following a step-by-step sequence where they Setup Wizard can specify data monitoring intervals and configure input channels (analog, digital or calculates) depending on the measurement Pods connected to the instrument. Users can configure threshold values that control the violation data recorded by the MP. Setup operation also includes setting the filename and formatting the data card in preparation for monitoring and writing of data. Continued on next page 1-12 CH 1/ Getting Started Trend Users can generate plots for all recorded data. Trend can simultaneously display up to four plots with two parameters per plot. Reports present data saved in Frames. A Frame is a record of sample scaled Reports measurements recorded at a fixed time interval or immediately upon detection of any trigger violation. Users have the option to view a record in more detail i.e. display its data plot, threshold values, or edit parameter settings. Users can also use the Export function which instantly stores a data file on a memory card in MS® Excel file format. Status presents a graphic summary of the limit compliance of analog input and Status calculation channels. It also shows if digital channels from logic inputs are on or off. The channels/parameters appear in user-specified labels or tag names and are color coded for limit conformance or on/off status. MP only supports the use of Dranetz-BMI supplied Compact Flash data cards with AT Data Card LEAST 32MB storage capacity. The user replaceable data card is used as primary storage for data. Data monitoring CANNOT proceed without the data card. The MP is designed to accommodate the Compact Flash card in its native format, and does not require the use of a PC card adapter. However, a PC card adapter can be used to read the data into a laptop or other computer with a PC card slot. 1-13 Basic Operation Basic Operation The normal power source for the MP is its internal battery pack. The AC Adapter/ Introduction Battery Charger is used to charge the battery. Always charge the battery fully before use. The MP will always operate on the charger and is designed to do so, regardless of the state of charge of the battery. Type: Sealed, rechargeable NiMH (Nickel Metal Hydride) cells. Battery pack Length of operation: The MP can operate on a fully charged battery pack for more than two (2) hours with the backlight on. When the backlight is turned off, the unit can operate for more than three (3) hours. For information on how to turn backlight on or off, see Chapter 6 Instrument Settings - Set Display Preferences on page 6-6. Charging: The battery pack can be charged by connecting the AC Adapter/Battery Charger to the MP. A screen warning will appear during operation when battery charge is low. A depleted battery pack can be recharged in six (6) hours whether the unit is on or off. The Battery Charge Indicator glows steadily while charging, and flashes when fully charged. NOTE: The Battery Charge Indicator functions whenever the AC Adapter/Battery Charger is properly connected. The MP can be operated from a 50/60 Hz 120/230V AC power source with or without AC power source the battery pack installed. Connect the AC Adapter output cable to the Input Connector on the right side of the MP. Connect the appropriate AC Adapter power cord for the country in which you are using the equipment into an appropriate ground outlet. Always use one of the available specified cords (refer to page 1-4) that have a protective ground terminal which must be connected to the protective ground earth. Refer to Appendix C for the specifications and replacement of the batteries contained in MP. 1-14 CH 1/ Getting Started Follow these steps to turn on the MP and display the Home screen. Power on sequence Step Action 1 Connect ac adapter/battery charger plug into the right side of MP. 2 Plug the ac adapter into an ac power source. 3 Press the MP On/Off power button to turn the unit on. Result: The Home screen will be displayed. MP001 Home screen is frequently referenced as the starting point for all major functionalities Home screen features of the MP. The date and time appear on the top right corner of the Home screen. Both can be configured to appear in a different format. See page 6-3 for the procedure on how to set and reformat the time and date. The unit name and model, MP program revision level, and status messages appear in the upper portion of the Home screen. Pertinent information that appear in the status message area include the monitoring status, amount of free space in data card, site/file name, and number of frames stored. MONITORING STATUS: OFF indicates that the instrument is not actively monitoring data. The monitoring status message will change to ON, DONE or ARMED, depending upon the state of data monitoring. See page 3-21 for the procedure on how to turn monitoring on/off. The Home screen contains the icons used to access the various MP functions. See page 1-16 for the description of each icon found in Home screen. 1-15 Basic Operation, continued Home screen contains the following icons used to access various MP functions. Note Home screen icons that data values are displayed only after the input channels have been set up and enabled. Start/Setup - Start/Setup contains functions to set up the application for monitoring, use existing setups for monitoring, load previously saved setups for monitoring, and transfer stored data from card to MP. See Chapter 3 Start/Setup Operations. Scope - Scope mode shows real-time waveforms of the signals on the measuring inputs. See Chapter 4 View Real Time Data - Section A Scope Mode. Meter - Meter readings come from analog inputs, digital inputs, and calculation channels. The values are color-coded for limit conformance. See Chapter 4 View Real Time Data - Section B Meter Mode. DFT - DFT screen displays a spectral graph and textual matrix featuring amplitude and harmonic frequeny for a selected input value. See Chapter 4 View Real Time Data - Section C DFT. Graph - Graph shows a horizontal bar graph of a selected channel value as a percent of the full scale value. See Chapter 4 View Real Time Data - Section D Graph. Reports - Reports contain records of limit-violations listed in the order that they occurred. Users have the option to view a record in more detail i.e. display its data plot, threshold values, or edit parameter settings. There is also the Export function which instantly stores a data file on a memory card in MS® Excel file format. See Chapter 5 View Recorded Data - Section A Reports. Trend - Trend allows users to view plots of recorded data. See Chapter 5 View Recorded Data - Section B Trend. Status - Status shows a quick overview of the limit conformance of analog input and calculation channels. It also shows the on/off status of digital input channels. See Chapter 5 View Recorded Data - Section C Status. Preferences - Users can set instrument preferences like time and date, threshold alarm feedback, language selection, LCD display, data card operation, and dictionary. See Chapter 6 Instrument Settings. 1-16 C H A P T E R 2 Input Pod Connection Overview This section describes the six types of external Pods and how they can be plugged in Introduction the instrument. Each Pod has different terminal connectors allowing fast and easy connection of various kinds of transducers or sensors to the MP. A maximum of four Pods per instrument is supported, where each Pod has four analog and two digital channels which can be enabled to send data in the instrument. In this chapter The following topics are covered in this chapter. Topic See Page Types of Measurement Pods 2-4 Pod Connections 2-5 Connecting the Pods to the Cable Panel 2-11 WARNING Death, serious injury, or fire hazard could result from improper connection of this instrument. Read and understand this manual before connecting this instrument. Follow all installation and operating instructions while using this instrument. Connection of this instrument to an electrical system must be performed in compliance with the National Electrical Code (ANSI/NFPA 70-2005) and any additional safety requirements applicable to your installation. Installation, operation, and maintenance of this instrument must be performed by qualified personnel only. The National Electrical Code defines a qualified person as "one who has the skills and knowledge related to the construction and operation of the electrical equipment and installations, and who has received safety training on the hazards involved". Qualified personnel who work on or near exposed energized electrical conductors must follow applicable safety related work practices and procedures including appropriate personal protective equipment in compliance with the Standard for Electrical Safety Requirements for Employee Workplaces (ANSI/NFPA 70E-2004) of USA and any additional workplace safety requirements applicable to your installation. Continued on next page 2-1 Overview, continued Una conexión incorrecta de este instrumento puede producir la muerte, lesiones ADVERTENCIA graves y riesgo de incendio. Lea y entienda este manual antes de conectar. Observe todas las instrucciones de instalación y operación durante el uso de este instrumento. La conexión de este instrumento a un sistema eléctrico se debe realizar en conformidad con el Código Eléctrico Nacional (ANSI/NFPA 70-2005) de los E.E.U.U., además de cualquier otra norma de seguridad correspondiente a su establecimiento. La instalación, operación y mantenimiento de este instrumento debe ser realizada por personal calificado solamente. El Código Eléctrico Nacional define a una persona calificada como "una que esté familiarizada con la construcción y operación del equipo y con los riesgos involucrados." El personal cualificado que trabaja encendido o acerca a los conductores eléctricos energizados expuestos debe seguir prácticas y procedimientos relacionados seguridad aplicable del trabajo incluyendo el equipo protector personal apropiado en conformidad con el estándar para los requisitos de seguridad eléctricos para los lugares de trabajo del empleado (ANSI/NFPA 70E- 2004) de los E.E.U.U. y cualquier requisito de seguridad adicional del lugar de trabajo aplicable a su instalación. AVERTISSEMENT Si l'instrument est mal connecté, la mort, des blessures graves, ou un danger d'incendie peuvent s'en suivre. Lisez attentivement ce manuel avant de connecter l'instrument. Lorsque vous utilisez l'instrument, suivez toutes les instructions d'installation et de service. Le raccordement de cet instrument à un système électrique doit être effectué conformément au Code Électrique National (ANSI/NFPA 70-2005) des Etats-Unis et à toutes les exigences de sécurité applicables à votre installation. Cet instrument doit être installé, utilisé et entretenu uniquement par un personnel qualifié. Selon le Code Électrique National, une personne est qualifiée si "elle connaît bien la construction et l'utilisation de l'équipement, ainsi que les dangers que cela implique". Le personnel qualifié qui travaillent dessus ou s'approchent des conducteurs électriques activés exposés doit suivre des pratiques en matière et des procédures reliées par sûreté applicable de travail comprenant le matériel de protection personnel approprié conformément à la norme pour des conditions de sûreté électriques pour les lieux de travail des employés (ANSI/NFPA 70E-2004) des Etats-Unis et toutes les conditions de sûreté additionnelles de lieu de travail applicables à votre installation. 2-2 CH 2/ Input Pod Connection WARNUNG Der falsche Anschluß dieses Gerätes kann Tod, schwere Verletzungen oder Feuer verursachen. Bevor Sie dieses Instrument anschließen, müssen Sie die Anleitung lesen und verstanden haben. Bei der Verwendung dieses Instruments müssen alle Installation- und Betriebsanweisungen beachtet werden. Anschluß dieses Instrumentes zu einem elektrischen System muß gemäß dem Nationalen Elektrischen Code (ANSI/NFPA 2005) der Vereinigten Staaten, und allen zusätzlichen Sicherheitsauflagen durchgeführt werden, die auf Ihre Installation anwendbar sind. Installation, Betrieb und Wartung dieses Instruments dürfen nur von Fachpersonal durchgeführt werden. In dem nationalen Bestimmungen für Elektrizität wird ein Fachmann als eine Person bezeichnet, welche "mit der Bauweise und dem Betrieb des Gerätes sowie den dazugehörigen Gefahren vertraut ist." Qualifiziertes Personal, das an bearbeiten oder herausgestellte angezogene elektrische Leiter sich nähern, muß anwendbare Sicherheit bezogener Arbeit Praxis und Verfahren einschließlich passende persönliche schützende Ausrüstung gemäß dem Standard für elektrische Sicherheitsauflagen für Angestellt- Arbeitsplätze (ANSI/NFPA 70E-2004) der Vereinigten Staaten und alle zusätzlichen Arbeitsplatzsicherheitsauflagen folgen, die auf Ihre Installation anwendbar sind. The following safety precautions must be followed whenever any type of voltage or Safety precautions current connection is being made to the MP. • Wear proper Personal Protective Equipment, including safety glasses and insulated gloves when making connections to power circuits. • Hands, shoes and floor must be dry when making any connection to a power line. • Before each use, inspect all cables for breaks or cracks in the insulation. Replace immediately if defective. • Set the MP power switch to Off. Before connecting to electric circuits to be monitored, open their related circuit breakers or disconnects. DO NOT install any connection of the MP to live power lines. • Pods should be connected first to the MP, then connect to the circuit to be monitored. • If the equipment is used in a manner not specified in this user’s guide, the protection provided by the equipment may be impaired. 2-3 Types of Measurement Pods Types of Measurement Pods The external Pods operate independently of each other when connected to the MP. Each Pod description Pod has different terminal connections which allows the instrument to operate with various sensors/transducers and to process signals in a wide range of measurement applications. The Pods are self-discoverable in that each has a memory device that the MP reads to detect the Pod type - whether it is a MP600V Voltage Pod, MP300V Voltage Pod, MP30V Voltage Pod, MP20MA Current Pod, MPUC Universal Current Clamp Pod, or MPUT Thermocouple Pod. The first four types have analog inputs with the ability to select AC (rms) or DC signals. Several TR current probes can be used with the MPUC pod. Digital inputs can be configured as frequency measuring, counter, state detector, quadrature, or reset (used to clear counters, reset min/max, etc). Thermocouple has some special functions such as Cold Junction Reference. Each channel has high/low limits that control trigger violation. Actual photos and part numbers are shown below to aid users in Pod identification. External pods are available as optional accessories for MP. See Appendix B Technical Specifications for the detailed specifications of each Pod type. MP600V Voltage Pod MP300V Voltage Pod MP30V Voltage Pod MP20MA Current Pod MPUC Universal Current Pod MPUT Thermocouple Pod 2-4 CH 2/ Input Pod Connection Pod Connections This section contains wiring diagrams of voltage and current connections required to Introduction connect transducers or sensors to the measurement Pods. The wiring configurations should assist users in the connection of Pod type appropriate for their application. To reduce the risk of fire, electric shock, or physical injury, it is strongly recommended WARNING that connections be made with all Pod inputs de-energized and current carrying conductors fused. If it is necessary to make connections on energized Pods, these must be performed by Qualified Personnel ONLY with proper Personal Protective Equipment. MP30V Pod connections DC Power + Voltage Supply +5 to 30 VDC - Common =10mA Digital Signal Digital Signal Source #1 Source #2 (Open Collector) (Relay Contacts) 30 VDC Max 30 VDC Max + Signal + Signal Analog Signal D1 Vcc D2 Analog Signal Source #1 Source #2 ±0 to 30 VDC ±0 to 30 VDC + + 0 to 24 VAC RMS X 0 to 24 VAC RMS X 1 2 - Signal - Signal – – - Signal - Signal – – Analog Signal 3 4 Analog Signal Source #3 Source #4 + + ±0 to 30 VDC ±0 to 30 VDC 0 to 24 VAC RMS X 0 to 24 VAC RMS X + Signal + Signal 2-5 Pod Connections, continued MP300V Pod connections DC Power + Voltage Supply +5 to 30 VDC - Common =10mA Digital Signal Digital Signal Source #1 Source #2 (Open Collector) (Relay Contacts) 30 VDC Max 30 VDC Max + Signal + Signal Analog Signal D1 Vcc D2 Analog Signal Source #1 Source #2 ±0 to 300 VDC ±0 to 300 VDC + + 0 to 240 VAC RMS X 0 to 240 VAC RMS X 1 2 - Signal - Signal – – - Signal - Signal – – Analog Signal 3 4 Analog Signal Source #3 Source #4 + + ±0 to 300 VDC ±0 to 300 VDC 0 to 240 VAC RMS X 0 to 240 VAC RMS X + Signal + Signal Note: Analog signal source connections must be made with test leads rated at =300V and terminated with safety banana plugs. 2-6 CH 2/ Input Pod Connection MP600V Pod connections DC Power + Voltage Supply +5 to 30 VDC - Common =10mA Digital Signal Digital Signal Source #1 Source #2 (Open Collector) (Relay Contacts) 30 VDC Max 30 VDC Max + Signal + Signal Analog Signal D1 Vcc D2 Analog Signal Source #1 Source #2 ±0 to 600 VDC ±0 to 600 VDC + + 0 to 600 VAC RMS X 0 to 600 VAC RMS X 1 2 - Signal - Signal – – - Signal - Signal – – Analog Signal 3 4 Analog Signal Source #3 Source #4 + + ±0 to 600 VDC ±0 to 600 VDC 0 to 600 VAC RMS X 0 to 600 VAC RMS X + Signal + Signal Note: Analog signal source connections must be made with test leads rated at =600V and terminated with safety banana plugs. 2-7 Pod Connections, continued MPUC Universal Current Clamp Pod connections DC Power + Voltage Supply +5 to 30 VDC - Common =10mA Digital Signal Digital Signal Source #1 Source #2 (Open Collector) (Relay Contacts) 30 VDC Max 30 VDC Max D1 Vcc D2 Analog Signal Analog Signal Source #1 Source #2 0 to 1.5 VAC RMS X 0 to 1.5 VAC RMS X 1 2 Analog Signal Analog Signal 3 4 Source #3 Source #4 0 to 1.5 VAC RMS X 0 to 1.5 VAC RMS X Note: MPUC analog signal source connects to TR current clamp probes available as optional accessories (see Appendix A Optional Accessories). 2-8 CH 2/ Input Pod Connection MP20mA Pod connections DC Power + Voltage Supply +5 to 30 VDC - Common =10mA Digital Signal Digital Signal Source #1 Source #2 (Open Collector) (Relay Contacts) 30 VDC Max 30 VDC Max + Signal + Signal Analog Signal D1 Vcc D2 Analog Signal Source #1 Source #2 ±0 to 20 mADC ±0 to 20 mADC + + 0 to 14 mAAC RMS X 0 to 14 mAAC RMS X 1 2 - Signal - Signal – – - Signal - Signal – – Analog Signal 3 4 Analog Signal Source #3 Source #4 + + ±0 to 20 mADC ±0 to 20 mADC 0 to 14 mAAC RMS X 0 to 14 mAAC RMS X + Signal + Signal 2-9 Pod Connections, continued MPUT Pod connections DC Power + Voltage Supply +5 to 30 VDC - Common =10mA Digital Signal Digital Signal Source #1 Source #2 (Open Collector) (Relay Contacts) 30 VDC Max 30 VDC Max Thermocouple #1 Thermocouple #2 D1 Vcc D2 1 2 + Signal + Signal + + - Signal - Signal – – CU CU + Signal + Signal + + - Signal - Signal – – CU CU 3 4 Thermocouple #3 Thermocouple #4 Note: Analog signal source connections must be made with thermocouple wire or thermocouple extension cable of the appropriate type (B, E, J, K, N, R, S, or T), and terminated with mini plugs. 2-10 CH 2/ Input Pod Connection Connecting the Pods to the Cable Panel The input connectors for measurement Pods are found on the top panel of the MP. The Pod connectors markings on the panel show the Channel labels for each connector - Pod A, Pod B, Pod C, and Pod D. Simply plug the external Pod to the connector channel that you prefer. The six types of Pods are designed to fit in any of the four Pod channels in the cable panel. Pods should be plugged in with the instrument powered off and Pod inputs de- energized. Once the Pods are plugged in and instrument turned on, the unit will automatically detect the Pod type. MP allows four Pods to connect to the instrument at the same time, in any combination. The Input Configuration screen under Start/Setup menu will display which Channel the Pod is connected to. See Chapter 3 Start/Setup Operations for more information on MP input configurations. Connect only Daytronic/Dranetz-BMI Pods to the cable connectors. WARNING 2-11 2-12 C H A P T E R 3 Start/Setup Operations Overview The Start/Setup functions allow users to perform the following: set up the MP for Start/Setup menu options monitoring of an entire process or piece of equipment, load previously saved setups from card, and load data from card. Setup configurations depend on user application and extent of familiarity with the operation of the intrument. The length of time to monitor a system can vary from a few minutes to a few weeks depending on user application. Setup Wizard takes the user through a series of screens prompting for information about the process to be monitored. The user is allowed to modify the default trigger parameters and intervals used to log data. The user sets up the external Pods which connect MP to transducers or sensors. The instrument can work with up to four Pods simultaneously, each Pod having 4 analog and 2 digital channels. Each channel in the Pod must be turned on individually, but any combination can be used. In addition, the user can also record data using Calculate functions that can be applied to up to 8 channels. Threshold limits can be set for each channel using any values within the acceptable range. If the limit is exceeded, a violation occurs and data will be stored at the user-defined rate until the user programmed depth has expired or the input is back within limits. Setup also includes filename and format card operations to prepare the instrument for data monitoring. Monitor using present setup makes use of the existing setup for monitoring. If a setup configuration has been previously saved to the card, you may load it using the menu below. Load setup from card enables you to use previously saved setups. If you wish to load a previously saved data file from the card, use the menu below. Load data from card allows you to transfer saved data from the memory card to the MP. 3-1 Overview, continued Follow these steps to display the Start/Setup Menu. Displaying Start Menu Action... Result... STEP 1: Press the MP On/Off power button to turn the unit on. The Home screen will be displayed. MP001 STEP 2: Press Start/Setup. The Start Menu will be displayed. MP100 This chapter is divided into five sections: In this chapter Section Title See Page A Setup Wizard 3-3 B Monitor using Present Setup 3-21 C Load Setup from Card 3-29 D Load Data from Card 3-30 3-2 CH 3/ Start/Setup Operations Section A Setup Wizard Overview MP allows users to configure multiple setups unique to their task or applications. Make Introduction sure that the external Pods through which input sensors connect to the MP are properly hooked up before setting up the instrument for monitoring. See Chapter 2 Input Pod Connection for information on how to connect external Pods to the instrument. Setup: A pre-set condition of parameter thresholds and frame capture settings for each Definitions channel that determines what will constitute a violation and how many data frames will be saved when this violation occurs. Violation: A violation occurs when a pre-set threshold is crossed. Violations result in a contiguous collection of frames that are saved into memory. A violation consists of the pre- trigger sample data (captured before the start and end of violation) and the maximum depth of violation data stored in frames. Both the time duration (in msec) to record pre-trigger data and the amount of violation data samples to store (in frames) are user-programmable. Parameter threshold : A value that the MP compares to a measurement to decide if a violation occurs. Also called a limit. For example, if the input voltage is measured as 135 Vrms, and the parameter threshold for voltage is 132 Vrms, MP saves this limit crossing to memory as a violation until depth expires or input is back within limits. Trigger MP constantly scans all active analog inputs at 10kHz, digital inputs at 40kHz, or calculates at mechanisms various rates based on formula. It evaluates the samples through the following triggering mechanisms: • Storing data by limit-violations. Applies to analog, digital and calculation channels. When Threshold Beeper is set to on, the unit will provide audible alarm signals when thresholds are crossed and violations occur (refer to Chapter 6 Instrument Settings on page 6-11 for the procedure to turn threshold beeper on/off ). See page 3-4. • Auto-saving data by time. This is used to store longer-term trend data at one second or longer intervals when no violations occur. See page 3-4. • Enabling digital input triggers from logic inputs. See page 3-8. • Manually starting and stopping monitoring. See page 3-22. The following topics are covered in this section. In this section Topic See Page Global Setting Menu 3-4 Input Configuration 3-6 Calculates Configuration 3-15 Violation Configuration 3-16 Site Name/Memory Card 3-17 3-3 Global Setting Menu Global Setting Menu The term “global” implies that all recording settings apply to analog, digital, and Global sampling and recording calculation channels which can have high and/or low limit ranges for violation setting triggering. When a limit is crossed, the instrument records data to include Pre-trigger samples before the start and end of violation. Data is saved in Frames, which consist of sample scaled measurements recorded at a fixed time interval. Users can change the rate by which data is saved to make it equal to or slower than the default scan rate. Analog channels are scanned at a fixed rate of 10 KHz per input channel. Digital channels are scanned at a rate of 40KHz. Calculate channels are scanned at various rates based on formula. Action... Result... From the Start Menu, press Setup Wizard to display the Global Setting Menu screen. The indicator window provides a graphic display of the value settings of the parameters below. • Press Storage Rate window to set how often data will be saved once limits are crossed. Storage occurs continuously at user- defined rate until all limits are cleared, or depth of storage has been exceeded, or memory space MP101 is full. • Press Recording Depth window to specify the amount of violation data samples that you want to store. The memory will fill and stop with violation records until the set recorder depth is reached if channel remains out of limits. • Press Pre-Trig Depth window to specify the time duration (in milliseconds) to save samples before the start and end of MP102 violation. • Press Auto-Log every window to set the time interval to record data even when no violations occur. Continued on next page 3-4 CH 3/ Start/Setup Operations Global sampling and recorder Action... Result... setting (continued) • Use the numeric keypad to enter values within the acceptable range. Press OK to accept new value or Press Cancel to discard changes and return to the previous screen. • When done with the event trigger settings, press Next and go to page 3-6. • Press Cancel to quit and return to Start menu. MP will record sample scaled measurements using the Auto-Log rate while no Auto-log rate vs. Storage rate violation occurs. Once the unit detects a trigger violation, recording will begin at a special Storage rate that can be up to high speed. Recording of violations will continue until all enabled channel inputs return within limits, or depth of storage has been exceeded, or memory space is full. If the channels returned within limits prior to the recording depth count being exceeded, then monitoring using the auto-log rate will begin again. If monitoring ends due to recording depth being exceeded or memory space being full, the unit will stop recording data until the user purposely turns monitoring on immediately or at a specified time and date (see Section B Monitor using Present Setup on page 3-21). 3-5 Input Configuration Input Configuration Sensors can connect to the MP via external Pods (see Chapter 2 Input Pod Connection Input channel settings for more information on the Pod accessories). Each Pod has four analog and two digital channels. Once the Pods are plugged in, the MP automatically detects the Pod type. Up to four Pods can connect to the instrument at the same time. Action... Result... From the Global Setting Menu screen, press Next to display Input Pod Configuration. The instrument auto-detects and displays the type of input Pod and the channel it connects. For Example: The screen shows MP30V Voltage Pod, MP300V Voltage Pod, MP20mA Current Pod, and MPUT Thermocouple Pod connected to Channels A, B, C and D respectively. MP103 • Press the Pod where you want to turn channels on or modify settings. Each channel in the Pod must be turned on individually, but any combination can be used. Example 1: Select a Pod and see page 3-7 for analog input settings. Example 2: Select a Pod and see page 3-8 for digital input settings. • When done configuring input Pods, press Next and go to page 3-15. • Press Cancel to quit and return to Start menu. 3-6 CH 3/ Start/Setup Operations Select the channel that you want to enable and monitor data from. The sample screens Analog input channel settings below show the input settings for an analog channel. Action... Result... The following screens will appear if an analog Check Enable to set data input channel is selected: configurations for the Analog channel. The settings below will affect how the channel will be scaled and displayed. • For Non-thermocouple Pods, select between AC (rms) or DC input signal. For Thermocouple Pods, press Range to select temperature o range and degree scale ( F or o C). MP104 • Press Tag window to enter channel label or tag name. Analog input settings for Non-thermocouple Pods. • Press Legend window to enter engineering units for the channel. • Press Full Scale window to enter the desired full scale reading versus volts or milliamps into the Pod. • Press Zero window to enter the desired zero offset value. MP105 • Press OK to accept value Analog input settings for Thermocouple Pods. settings and return to Input Pod Configuration screen. • Press Cancel to discard changes in value settings and return to Input Pod Configuration screen. MP110 3-7 Input Configuration, continued Digital input The example below shows the input settings for a digital channel. channel settings Action... Result... Check Enable to set data The following screens will appear if a digital configurations for the Digital input channel is selected: channel. The settings below will affect how the channel will be processed and displayed. • Press Tag window to enter channel label or tag name. • Press Legend window to enter engineering units for the channel. • Press Function window to display the available logic input settings for the digital channel. MP104b A digital input can be configured as a: • Global Reset • Log trigger • Frequency channel • Counter • Quad encoder See pages 3-9 to 3-14 for the description of each digital input setting. • Press OK to accept the digital input settings and return to MP105b Input Pod Configuration screen. • Press Cancel to discard changes in settings and return to Input Pod Configuration screen. MP105c 3-8 CH 3/ Start/Setup Operations Digital inputs can be configured to work as a: Global Reset, Log Trigger, Frequency Digital settings channel, Counter, or Quad Encoder. Digital functions are typically used to input digital signals from switches, contacts, and frequency generating devices. Digital channels are scanned at a rate of 40kHz (four times the analog input scan rate). The next section shows the possible input settings for the digital channel. Digital input as Global Reset is used to clear counters. 1 2 3 4 5 MP105d1 6 7 Function 1 Enable. Check/Uncheck the box to turn the channel on/off. 2 Tag. Press to enter a user-specified label or tag name for the channel. 3 Legend. Press to enter the engineering units appropriate for the channel application. 4 Function. Shows the digital function setting for the channel. Press to modify. 5 Edge Trigger. Toggles between iiii,iiii, iiii . ii 6 OK. Press to accept the channel input setting and return to the Input Pod Configuration screen. 7 Cancel. Press to discard changes in channel input setting and return to the Input Pod Configuration screen. Continued on next page 3-9 Input Configuration, continued Digital input as Log Trigger. In this configuration, a frame will be saved when a trigger Digital settings (continued) is detected. 1 3 2 5 4 MP105d2 6 7 Function 1 Enable. Check/Uncheck the box to turn the channel on/off. 2 Tag. Press to enter a user-specified label or tag name for the channel. 3 Legend. Press to enter the engineering units appropriate for the channel application. 4 Function. Shows the digital function setting for the channel. Press to modify. 5 Trigger Level. Toggles between 0, 1. 6 OK. Press to accept the channel input setting and return to the Input Pod Configuration screen. 7 Cancel. Press to discard changes in the channel input setting and return to the Input Pod Configuration screen. Continued on next page 3-10 CH 3/ Start/Setup Operations Digital input as a Frequency counter. In this configuration, the digital input measures Digital settings (continued) the frequency of state transitions over the specified window. Hint: To measure frequency in Hz, set the Scale to 1 and the Edge to ffffoor fff. 1 3 2 5 4 6 7 MP105d3 8 9 Function 1 Enable. Check/Uncheck the box to turn the channel on/off. 2 Tag. Press to enter a user-specified label or tag name for the channel. 3 Legend. Press to enter the engineering units appropriate for the channel application. 4 Function. Shows the digital function setting for the channel. Press to modify. 5 Edge Trigger. Toggles between iiii,iii , iiii. i 6 Measurement Window (sec) of which the frequency measurement is taken. 7 Scale. The factor by which the number of scale divisions recorded by the instrument must be multiplied to compute the measurement value. 8 OK. Press to accept the channel input setting and return to the Input Pod Configuration screen. 9 Cancel. Press to discard changes in the channel input setting and return to the Input Pod Configuration screen. Continued on next page 3-11 Input Configuration, continued Digital input as a Counter. In this configuration, the input counts the number of state Digital settings (continued) transitions. The counter is reset by another digital input that is configured as Global Reset. 1 3 2 5 4 6 7 MP105d6 8 9 Function 1 Enable. Check/Uncheck the box to turn the channel on/off. 2 Tag. Press to enter a user-specified label or tag name for the channel. 3 Legend. Press to enter the engineering units appropriate for the channel application. 4 Function. Shows the digital function setting for the channel. Press to modify. 5 Edge Trigger. Toggles between iiii,iii , iiii. i 6 Debounce (uSec). If set, this value shows the number of microseconds to wait before considering a new transition valid. 7 Scale. The factor by which the number of scale divisions recorded by the instrument must be multiplied to compute the measurement value. 8 OK. Press to accept the channel input setting and return to the Input Pod Configuration screen. 9 Cancel. Press to discard changes in the channel input setting and return to the Input Pod Configuration screen. Continued on next page 3-12 CH 3/ Start/Setup Operations Both digital inputs of the Pod are required for the Quadrature Encoder function. Digital settings (continued) Typically, input 1 measures the speed while input 2 measures the phase. Another channel can be assigned as the z input in order to provide phase reference. MP105d8 1 3 2 4 5 7 6 MP105d9 8 9 See screen legend on page 3-14. Continued on next page 3-13 Input Configuration, continued Digital settings (continued) Function 1 Enable. Check/Uncheck the box to turn the channel on/off. 2 Tag. Press to enter a user-specified label or tag name for the channel. 3 Legend. Press to enter the engineering units appropriate for the channel application. 4 Function. Shows the digital function setting for the channel. Press to modify . 5 ‘Z’ Input. An external input (digital input from another Pod) that is considered as Phase. Also known as Phase Reference. 6 Pulses/Rev. The sum of the A and B pulses per revolution. 7 Scale. The factor by which the number of scale divisions recorded by the instrument must be multiplied to compute the measurement value. 8 OK. Press to accept the channel input setting and return to the Input Pod Configuration screen. 9 Cancel. Press to discard changes in the channel input setting and return to the Input Pod Configuration screen. 3-14 CH 3/ Start/Setup Operations Calculates Configuration Calculates are math functions that can be applied to one or two channels, be it analog, Calculation channel settings digital or another calculate channel. Up to eight internal cross-channel math calculations can be set up for display. Calculation channels can be used to monitor additional process variables such as horsepower, efficiency, and corrected flow. Action... Result... From the Input Pod Configuration screen, press Next to display Calculates Configuration. Check Enable to set data configurations for the calculation channel. • Press Tag window to enter channel label or tag name. • Press Legend window to enter MP112 engineering units for the channel. • Press Equation window to show the list of math equations that can be applied to input channels. • Click on the corresponding equation variable m or b to enter desired values. • Click on the corresponding MP113 equation variable x or z to enter desired channels. • When done configuring calculation channels, press Next and go to page 3-16. • Press Cancel to quit and return to Start menu. MP114 NOTE: Inter-channel mathematics can be configured for purposes of user readability in engineering units suitable for the application i.e. add, subtract, multiply, divide, absolute, maximum, minimum, average, square root. 3-15 Violation Configuration Violation Configuration Each analog, digital (when configured as a frequency channel, timer, or quad encoder), Logging data by limits and calculation channel has threshold limits that serve as triggers of violations. Users can set the threshold units by which high and low limits of voltage and current trigger are calculated. Thresholds are set in ranges with high limit (threshold above the normal range) and low limit (threshold below the normal range). All limit values are used to determine if corresponding reporting action should take place. Action... Result... From the Calculates Configuration screen, press Next to display Violation Configuration. • Press to select the channel/ parameter where you want to set limits to capture violation data. The limit fields will be activated to allow you to enter values. Meter values for voltage and current inputs are also displayed for active MP116 channels. Use the numeric keypad to enter threshold values for High Limit, Low Limit, or both for the corresponding channel. High Limit: specifies an absolute limit for comparison that is higher than the low limit. Low Limit: specifies an absolute limit for comparison that is lower than the high limit. MP118 • Once a limit is set, and you want to turn the limit off, use the Disable button on the keypad. • When done with violation configurations, press Next and go to page 3-17. • Press Cancel to quit and return to Start menu. MP119 3-16 CH 3/ Start/Setup Operations Site Name/Memory Card The MP uses the Compact Flash data card as primary storage for data. It automatically Where you can save data saves data in the card when monitoring is on. The Compact Flash card must be installed in either data card Slot 1 or Slot 2 in order to record data. NOTE: Although MP is able to detect availability of data card in either slot, Dranetz- BMI strongly recommends the use of only one card slot (one data card) at a time. The MP requires a Compact Flash data card with minimum storage capacity of 32MB, Data card size maximum of 256MB. See Appendix A Optional Accessories for the part numbers of Compact Flash cards supplied by Dranetz-BMI. NOTE: Dranetz-BMI Compact Flash data cards have been tested to work properly with the MP. Non-Dranetz-BMI Compact Flash cards may not be compatible with the instrument and cannot be supported by Dranetz-BMI Customer Service in case problems arise. Users are advised to use only Dranetz-BMI parts and accessories. The following files are created on the data card: filename.set for setups and Filename filename.ddb for saved violations. The maximum allowable length for a site/file name is 32 characters. The final step in Setup Wizard is configuring the filename and formatting the data card Data card screen prior to monitoring. The Site Name/Memory Card screen reports the current operational status of the data card. MP120 The following messages may appear in the data card status line. Data card status messages Status Message Description Not Inserted Data card not inserted or not detected. Insert a valid data card to proceed. Empty Data card is empty. Contains File Data card presently contains files. Continued on next page 3-17 Site Name/Memory Card, continued Data card status Status Message Description messages Fragmented A fragmented FAT was detected. Monitoring cannot proceed with (continued) a fragmented data card. Either change the data card or format to continue. Unformatted Data card is not formatted. Format the data card or replace with a different card to continue. Invalid Card Data card is not valid for monitoring. Change the data card to proceed. The data card screen prompts users to set filename and format card in preparation for Data card operation monitoring and writing of data. Action... Result... STEP 1: From the Violation Configuration screen, press Next to display data card status. • If the default filename is acceptable without change, and if the card is formatted to save data, press Finish. The system is ready to begin monitoring. Go to Section B Monitor using Present Setup on page 3-21. • Press Change to enter a new site/file name. Proceed to Step 2 on page 3-19. MP120 • Press Format card to format the data card. NOTE: All data and setups stored in data card will be lost when you format the card. Copy any files that you want to save to a computer first before formatting card. • Press Memory Card Contents to view list of data files stored in card. • Press Cancel to discard changes and return to Start Menu. Continued on next page 3-18 CH 3/ Start/Setup Operations Data card operation Action... Result... (continued) STEP 2: Enter a new site/file name using the keypad. Press OK to accept the new site/file name. • Press Shift to enter a character in uppercase. • Press CAPS to enter all characters in uppercase. • Press Space to enter a space in between characters. • Press Clear All to delete the entire name on the space MP121 provided. • Press .. . .. to erase a character. • Press Cancel to retain the default site/file name and return to Site Name/Memory Card screen. Saving the current setup means writing the current configuration and threshold settings Writing setup to data card to the data card. Configurations and setups include the following: • Input Pod and Global Setup • Analog and digital channel configuration • Calculates configuration • Violation configuration • Site name NOTE: The filename extension for the setup is SET, i.e. filename.set. 3-19 Site Name/Memory Card, continued The MP treats the Compact Flash card like a hard disk storing files in DOS format. For Guidelines on file data transfer successful card data transfer, keep the following points in mind: • MP supports a maximum DOS directory size of 256MB. Minimum required Compact Flash data card size is 32MB. • Compact Flash cards allow users to store multiple files in one card. The Site name will be used as the filename for record files (i.e. if the site name is MeasuringPad Site, the filename will be MeasuringPad Site00.DDB). A number is automatically appended to the name such that filenames are automatically incremented every time the user starts monitoring with that same filename. • MP does not support file fragmentation. When creating a file, it will take the largest contiguous block and use that size block for data storage. You cannot use the unit to delete individual files from the data card. When there is no more space available to begin new data storage, transfer the data files to a computer and then reformat the card using the MP. 3-20 CH 3/ Start/Setup Operations Section B Monitor using Present Setup Overview Menu options for monitoring become available only after setting up the instrument or Introduction loading a setup from the data card. Users have the option to begin monitoring immediately or at a specified time and date. Monitoring options The following topics are covered in this section. In this section Topic See Page Turning Monitoring On/Off 3-22 Monitoring at a Specified Time and Date 3-25 3-21 Turning Monitoring On/Off Turning Monitoring On/Off Follow these steps to start and end monitoring. Start/Stop monitoring Action... Result... STEP 1: From the Start Menu screen (see page 3-2), press Monitor using Present Setup. NOTE: Monitoring Menu screen will only be available after setting up the instrument or loading a setup from card. OR STEP 1: At the end of Setup Wizard, the Site Name/Memory Card screen prompts users to press Finish so as to start monitoring (see page 3-18). The Monitoring Menu screen will be MP125 displayed. • To start monitoring at the Auto-Log rate, press Start Now! Proceed to Step 2 on page 3-23. • To start and end monitoring at a specified date and time, press Monitor using Start and End times. Go to page 3-25. • To review the present setups, press View Setup Summary. Proceed to Step 5 on page 3-24. • Press Save Setup to Card to load a setup to the data card. • Press Exit to cancel and return to Home screen. Continued on next page 3-22 CH 3/ Start/Setup Operations Start/Stop Action... Result... monitoring (continued) STEP 2: While the instrument is actively monitoring data, the message MONITORING STATUS: ON appears on the top section of the Home screen (see NOTE). Users cannot change the time and date nor perform data card operations while the instrument is actively monitoring data. However, the rest of the function keys, including date style and clock style, are operable even MP126 while monitoring status is ON. NOTE: The following status messages are displayed after monitoring is turned on. • To end monitoring, press Stop. Proceed to Step 3. MONITORING STATUS: ON (monitoring will continue until Stop is pressed or when specified end time is reached) MEMORY CARD: xx MB Free (remaining space in the data card in megabytes) SITE NAME: User specified or MeasuringPad Site xx.ddb (where xx increments every time data is saved using the same file name) FRAMES LOGGED: xx (counter on the number of data frames recorded) START TIME: start time and date are displayed while monitoring is on STEP 3: Stop Monitoring Menu confirms whether users want to end monitoring, cancel monitoring, or view present setup. • To turn monitoring off, press Stop Now! This will save any pending data and close the file. Proceed to Step 4 on page 3-24. • To cancel monitoring, press Abort. All data collected will be lost when monitoring is aborted. • To view setup, press View present setup. This will not save any monitoring parameters. MP127 Proceed to Step 5 on page 3-24. • To continue monitoring, press Exit. Continued on next page 3-23 Turning Monitoring On/Off, continued Start/Stop monitoring Action... Result... (continued) STEP 4: When monitoring ends, the message MONITORING STATUS: DONE appears on screen (see NOTES). • To capture a new set of data or to edit threshold settings, press Start/Setup. The Start Menu screen will be displayed. Go to page 3-2. • To view data, press Trend or Reports. Go to Chapter 5 View Recorded Data. MP004 NOTE 1: The message MONITORING STATUS: DONE appears to indicate that monitoring is completed and active recording is disabled. NOTE 2: The Reports button will display data if periodic measurements at regular intervals are available or if thresholds have been crossed. See Chapter 5 View Recorded Data. STEP 5: Press View present setup to display the parameter settings in effect. Setup summary is available for review before, during, and after monitoring. • Press Up/Down arrow keys to scroll the page up or down by one line. • Press and drag the scroll bar to move the page up or down. • When done reviewing the MP130 Setup Summary, press Exit. The screen will return to the Stop Monitoring Menu options on page 3-23. 3-24 CH 3/ Start/Setup Operations Monitoring at a Specified Time and Date Follow these steps to set monitoring at a specified time and date. Schedule monitoring Action... Result... STEP 1: From the Start Menu screen (see page 3-2), press Monitor using Present Setup. NOTE: The Monitoring Menu screen will only be available after setting up the instrument or loading a setup from the data card. OR STEP 1: At the end of Setup Wizard, the Site Name/Memory Card screen prompts users to press Finish so as to start monitoring (see page 3-18). The Monitoring Menu screen will be displayed. MP125 • To set monitoring at a specified date and time, press Monitor using Start and End times. Proceed to Step 2. For functional descriptions of the other buttons, refer to Section B Monitor using Present Setup - Turning Monitoring On/Off on page 3-22. STEP 2: The MP will monitor and collect data using either of the following monitoring schedules: • Press Start & End time to specify the date/time when the unit will begin and end monitoring. See page 3-26. • Press Time Interval to specify the length of the recording interval for each file, and the time/date to start monitoring interval. See page 3-28. • Press Cancel to quit and return MP131 to the monitoring menu. 3-25 Monitoring at a Specified Time and Date, continued You can specify the date and time when the unit will begin and end monitoring. Monitoring using start & end time Action... Result... STEP 1: When monitoring using the Start & End time schedule, the current date and time (set to the next full hour) are displayed on screen. • Start at: indicates the date and time when the unit will begin data monitoring. • End at: indicates the date and time when the unit will stop data monitoring. By default, the system will automatically end monitoring one MP132 week from the time/date monitoring starts. However, users are allowed to specify their own time/date when they want to stop monitoring. For Example: Set monitoring to - Start at: March 12, 2005; 18:00:00 End at: March 19, 2005; 18:00:00 Press the End at: Date and Time keys and proceed to Step 2. • Press OK to accept the settings and return to Home screen. • Press Cancel to retain previous monitoring settings and return to Home screen. STEP 2: Use the Date and Time function keys to set when monitoring will start and end. • Press Date to enter desired month-day-year to start/end monitoring. Use the numeric keypad to enter the year. • Press OK to accept changes in date settings. Continue with Step 2 on page 3-27. • Press Cancel to discard changes in date and return to Monitoring Control Menu. MP133 Continued on next page 3-26 CH 3/ Start/Setup Operations Monitoring using start & Action... Result... end time (continued) STEP 2 (continued): • Press Time to enter desired hour-minute-second to start/ end monitoring. Press to select the hour/minute/second field to display the numeric keypad. Use the keypad to enter time settings. • Press OK to accept changes in time settings. The screen will display the new settings once the monitoring Start time/date and End time/date have been MP134 set. Proceed to Step 3. • Press Cancel to discard changes in time and return to Monitoring Control Menu. STEP 3: After specifying the Start and End time/date of monitoring, the message MONITORING STATUS: ARMED appears on screen. Armed means that the system will automatically begin monitoring at the specified Start time and date. Once monitoring status is ON, follow the Start/Stop monitoring procedure found on page 3-23. MP136 3-27 Monitoring at a Specified Time and Date, continued Monitoring at You can specify the date and time when the unit will begin monitoring, and choose scheduled from the following interval cycles when the unit will end recording and start a new file: intervals daily, weekly, bi-weekly, or a customized number of days. Action... Result... STEP 1: When monitoring using Time Interval, the current date and time (set to the next full hour) are displayed on screen. Select the interval schedule on how often you want the unit to automatically end and start a new data file. • Start at: Indicates the date and time when the unit will begin monitoring. • Interval: Indicates the time period when the unit will automatically collect and download event data. • Daily: Monitors data in 24-hour MP135 cycle and then starts a new file. The unit will append the filename for data collected every 24 hours. • Weekly: Monitors data in 7-day cycle and then starts a new file. The unit will append the filename for data collected every 7 days. • Bi-Weekly: Monitors data in 14-day cycle and then starts a new file. The unit will append the filename for data collected every 14 days. • Custom: The user specifies the MP135b time period (in days) when the unit will end recording interval. Press Change to set new time interval. • Press OK to accept the settings and return to Home screen. The message MONITORING STATUS: ARMED appears on screen. • Press Cancel to retain previous monitoring settings and return to Home screen. 3-28 CH 3/ Start/Setup Operations Section C Load Setup from Card Overview MP enables users to load saved setup files (.set) from the data card. Introduction NOTE: Loading a setup from the card will overwrite your existing setup. Loading saved Action... Result... setups STEP 1: From the Start Menu, press Load setup from card. MP lists the setup files (.set) stored in data card, along with file size, time and date when the setup files were recorded. Setup files are arranged in the order of date and time they were recorded. • Press Up/Down arrow keys to scroll the page up or down by one line. • Press to select (highlight) the desired setup file. MP140 • Press OK to load setup from card to MP. Proceed to Step 2. • Press Cancel to quit and return to Start Menu. STEP 2: The message Setup Loaded appears once the setup is successfully loaded from the data card to MP. • Press OK to exit. The Monitoring Menu screen will appear and users can begin monitoring. MP141 3-29 Overview Section D Load Data from Card Overview Data files (.ddb) consist of violations that are saved to the data card while monitoring is Introduction on. MP allows users to load stored data directly from card. The following topics are covered in this section. In this section Topic See Page Loading Data from Card 3-30 Card Error Messages 3-31 Follow these steps to load data from card. Loading data from card Action... Result... STEP 1: From the Start Menu, press Load data from card. The MP lists the data files (.ddb) stored in card, along with file size, time and date when data files were recorded. Data files are arranged in the order of date and time they were recorded. • Press Up/Down arrow keys to scroll the page up or down by one line. • Press to select (highlight) the desired data file. MP142 • Press OK to load data from card to the MP and return to Home screen. • Press Cancel to quit and return to Start Menu. If an error message is displayed, refer to Card Error Messages on page 3-31. NOTE 3-30 CH 3/ Start/Setup Operations Card Error Messages The following error messages may be displayed. Error messages Error Message Description Card not inserted No data card inserted or inserted improperly. Card not ready The Compact Flash data card controller is not ready. Try reinserting the data card. Card read error The data contains errors or the file has an invalid version. No files on card No valid data file on card. 3-31 3-32 C H A P T E R 4 View Real Time Data Overview The MP allows users to view measurement data as it happens, when it happens. The Introduction instrument is able to capture and process data in real time, and allows users to view it in Scope mode, Meter mode, DFT, and Graph. Icons for Scope mode, Meter mode, DFT, and Graph are available in the Home screen. Access to real time data MP001 This chapter is divided into four sections. In this chapter Section Title See Page A Scope Mode 4-2 B Meter Mode 4-6 C DFT 4-10 D Graph 4-14 4-1 Overview Section A Scope Mode Overview The Scope is designed to emulate a traditional analog oscilloscope. Scope mode allows Introduction you to view real-time waveforms for up to ten channels simultaneously. Press Scope on the Home screen to access the Scope key functions. Note that you have Scope screen to turn the channels on to view data plots in Scope mode (see screen below). Plotted channels and vertical scale; Select a channel to edit plot (see page 4-4) Turn channels on/off (p. 4-3) horizontal axis time/division MP201b Magnify button to Options to scale Return to Home screen narrow in or expand horizontal/vertical time scale (p. 4-5) axis, change waveform format, disable/enable channels to plot (p. 4-5) The following topics are covered in this section. In this section Topic See Page Turn Channels On/Off 4-3 Edit Plot 4-4 Scope Options 4-5 4-2 CH 4/ View Real Time Data Turn Channels On/Off All channels are disabled by default from the factory. Once the Scope screen is Enabling or disabling connfigured, enabled channels are stored in memory upon exiting the Scope screen. channels Only activated channels can be selected for display. The channel selection screen allows you to disable or select a channel for a particular Channel selection screen plot. To select a channel, simply select an active Pod where the channel of interest is grouped. MP201 MP202 Use the Disable button if you want to turn off the active channels. The parameters in color are the active channels. Those in gray indicates that none of the channels in the Pod are enabled. Once a Pod has been selected, the next screen allows you to select a specific channel in the Pod. MP203 4-3 Edit Plot Edit Plot Users have the option to edit the plot display for further analysis. The selected plot Edit plot functions appears in color, while other plots appear in gray. 7 1 2 3 4 5 MP212b 6 Function 1 Parameter. Shows the parameter currently being displayed. Press to change the parameter. 2 Y Scale. Shows the vertical value of the active plot. Setting to a higher number will make the plot smaller and vice versa. 3 Trigger. Shows the current trigger mode to synchronize input signals. Note that on the main scope screen, the trigger is marked by an asterisk (*). Press to step through the following selections: Auto Continuously updates the sweep regardless of the slope Slope: + Updates the sweep on the positive (+) slope, using the level selected by the “Trig Level” button Slope: - Updates the sweep on the negative (-) slope, using the level selected by the “Trig Level” button Other Channel Another channel is used as trigger to the sweep NOTE: The Scope trigger function is not the same trigger used to store data when a violation occurs. 4 Coupling. Selects the way in which the signal is interpreted by the Scope. Press to step through the following selections: DC Signal is directly coupled AC Signal is shown with its average value removed Ground The ground reference is shown instead of the signal 5 Channel Color. Show the current color code for the channel on display. Press to change color selection for channel . 6 Trig Level. Determines the amplitude point of the input signal required to trigger the sweep. Adjust by moving the trigger level bar up or down. 7 Y-Pos. Controls the vertical position of the plot relative to other plots on screen. Scroll the bar up or down to move plot up or down the screen. 4-4 CH 4/ View Real Time Data Scope Options The optional functions in Scope mode allow users to view plot waveforms in greater Optional display functions detail and give them greater flexibility in managing the display screen. MP206 1 2 3 4 5 MP207 Function 1 Magnify buttons. Zoom function keys have a plus/minus sign to zoom in/out on plot display. 2 Number of Y Divs. Shows the value for the vertical axis division. Pretrig mSec. Shows the value for the horizontal axis division. 3 Smooth. Displays plot coordinates in smooth continuous form. Dots. Displays plot coordinates in dotted form. 4 Enabled Channels. Shows the number of channels available to plot on screen. 5 Stack. Stacks enable plots to appear evenly on screen. 4-5 Overview Section B Meter Mode Overview Meter mode allows you to view real-time meter data. The instrument is able to generate Introduction meter readings from voltage and current inputs, user-defined calculate functions, and/or thermocouple devices. Metered parameters depend on user setup. The following topics are covered in this section. In this section Topic See Page Physical Inputs 4-7 Calculates 4-8 Thermocouple Function 4-9 4-6 CH 4/ View Real Time Data Physical Inputs The first page of the meter screen shows the measured value across the input terminals. Meter screen NOTE: Meter mode operation does not interfere with any of MP’s other monitoring or recording functions. MP300 Return to Home screen Displays Displays meter meter reading readings for for calculated Thermocouple Cold parameters Junction temperature (p. 4-8) (p. 4-9) The metered parameters on screen are based on user-specified labels or tag names. Disabled channels are not shown in the meter screen. Meter values are color-coded such that those that appear in black means they are within threshold limits, values that appear in red means they are out of limits. See Chapter 3 Start/Setup Operations - Section A Setup Wizard for more information on input configurations. 4-7 Calculates Calculates Calculates are math functions that can be applied to one or two channels, which can Calculates meter screen either be analog, digital or another calculate. MP is programmed to convert input readings from the math equations into usable engineering units that appear in the Calculates meter table. Up to eight internal cross- channel math calculations can be set up for display. Similar to input channels, the user can also assign labels or tag names for each calculate channel. MP301 Displays meter Return to Home screen Displays meter reading for reading for physical input thermocouple cold (p. 4-7) junction temperature (p. 4-9) See Chapter 3 Start/Setup Operations - Section A Setup Wizard for more information on calculates configuration. 4-8 CH 4/ View Real Time Data Thermocouple Function MP allows users to enter the type of thermocouple used in the application. Users will Thermocouple meter screen have to set up and enable the thermocouple settings during setup operations in order to generate temperature readings for the Thermal Cold Junction Reference table. MP302 Displays meter Displays meter Return to Home screen reading for reading for physical input calculated (p. 4-7) parameters (p. 4-8) See Chapter 3 Start/Setup Operations - Section A Setup Wizard for more information on thermocouple settings. 4-9 Overview Section C DFT (Discrete Fourier Transform) Overview MP allows users to view a scaled plot of a complex series of a Discrete Fourier What is DFT? Transform (DFT) known as frequency spectrum. Fourier transforms provide a way to convert samples of a standard time-series into the frequency domain. DFTs are useful because they reveal periodicities in input data as well as the relative strengths of any periodic components. The following topics are covered in this section. In this section Topic See Page DFT Spectrum Graph 4-11 Graph Details 4-12 Frequency Spectrum List 4-13 4-10 CH 4/ View Real Time Data DFT Spectrum Graph The spectrum graph can be displayed by pressing DFT on the Home screen. Once input Graph display channels are enabled, the screen defaults to a graphical spectrum display. The graph shows the magnitude of the frequency components. The vertical axis features amplitude values showing the magnitude of variation in a changing quantity from its zero value. The horizontal axis represents the frequency components and are displayed in Hertz. The graphs can be zoomed and rescaled. Measurement scale Display is for Amplitude of updated frequency component approximately (y axis) once per second Measurement scale for Frequency of harmonics (x axis) MP226 Change Magnify DFT Show frequency parameter graph (p. 4-12) component text (p. 4-13) 4-11 Graph Details Graph Details MP allows users to determine the numbers or the range of frequency components to Graph trends display. A green box showing the default zoomed area appears once the Detail button is pressed. Touch any side of the zoom box to activate the drag function. Touch and drag the sides of the zoom box to expand or narrow in on a select number of harmonic graphs. The zoom box moves horizontally only. The vertical scale will autoscale when zoomed. touch and drag zoom box to desired magnification scope MP227 MP227b MP227c The magnify buttons serve as zoom function keys, each of which feature a plus sign or a minus sign within. Press Zoom+ to display the zoomed area and view spectrum graphs in greater detail. Users may repeatedly zoom in on a plot for up to seven (7) levels. Press Zoom-(n) to unzoom graph display one increment at a time, where n is the counter of how many times the spectrum graphs have been magnified. 4-12 CH 4/ View Real Time Data Frequency Spectrum List To view the frequency spectrum magnitude text display, press List from the DFT Harmonic text display graph. The list displays frequency components in Hz. By default, the frequency values are arranged per increment of 5Hz. Use the Sort button to organize harmonic text display in order of ascending frequency or in order of descending magnitude. Display is updated approximately once per second MP229 MP230 4-13 Overview Section D Graph Overview The Graph displays the selected channel values in horizontal bar graph form. The Enable channels to display channels appear in user-specified labels or tag names. graphs The following topics are covered in this section. In this section Topic See Page Graph Display 4-14 The graph displayed on screen is shown autoscaled as a percent of the full scale value Graph display that was configured under Setup Wizard (see Chapter 3 Start/Setup Operations -Section A Setup Wizard on page 3-3), with zero percent to the right. Actual percent values appear in text form on top of the graphs. The values are color coded in the same way that the bar graphs are. MP243 Enable parameter Disable parameter in graph from graph Use the (+)Param/(-)Param command buttons to enable/disable the horizontal bar graph of a selected channel. Depending on the channels being monitored, up to eight bar graphs may be displayed at any one time. 4-14 C H A P T E R 5 View Recorded Data Overview MP offers a graphical display of recorded data. The firmware architecture of MP is Types of data display designed to engage in various stages of acquisition and visualization of auto-saved data and violation data. Reports: Reports display data saved in Frames. A Frame consists of sample scaled measurements recorded at fixed time interval or immediately upon detection of any trigger violation. A violation occurs when a programmed threshold is crossed. Trend: A trend is a graph of the value of one or more parameter or channel over time. Trends aim to show a macro view of auto-saved data. Data saved due to a violation is also displayed. Users can zoom in on trends for a more detailed view. Status: Status displays a quick overview of the limit compliance of measurement values for analog, calculation, and numeric digital (frequency, counter, quad encoder) channels. It also shows whether the digital channel reset and log trigger are on or off. The Reports, Trend, and Status icons are used to view recorded data. All icons are Icons to view recorded data accessible at the Home page. The Reports button displays records of auto-log (time-based) and violation (trigger- based) data, record Detail magnification, and Param to change and/or add parameters/ channels to plot. A convenient Export command button is also available to store a ® recorded data file in MS Excel format. NOTE: Record data becomes available while the instrument is monitoring or by loading a previously saved file from the data card. Otherwise, a message appears indicating that there is no data available to view. The Trend button displays time plots of auto-log and violation (if triggered) data. Data from analog, digital and calculation channels are available to plot. The Trend screen can display up to four plots, with a maximum of two parameters per plot. One parameter can have multiple channels to plot. Users have the option to enable/disable plot display, where display area will resize according to the number of plots for active display. The Trend screen also features a Zoom box, where users can expand or narrow the zoomed area via touch and drag. Users can select the trend coordinates to view in detail. Continued on next page 5-1 Overview, continued The Status button presents a summary of the limit conformance or on/off status of Icons to view recorded data measurement values. The values appear in user-specified labels or tag names and are (continued) color-coded for limit conformance or on/off status. The user may choose to clear or reset existing data status on the panel and restart time/date from which the panel will monitor status anew. Follow these steps to display data. View Recorded Data using Reports, Trend, Action... Result... Status STEP 1: Reports, Trend and Status are accessible from the Home screen. Note that data will be available for display while monitoring or upon reading a stored file from the data card. A monitoring status message appears on the top section of the screen. Refer to Chapter 3 Start/ Setup Operations for the procedure on how to turn monitoring on. MP004 • Press Reports to view the list and graphs of recorded data. Proceed to Section A - Reports on page 5-3. • Press Trend to view time plots. Proceed to Section B - Trend on page 5-12. • Press Status to view limit compliance of measurement values. Proceed to Section C - Status on page 5-14. This chapter covers the following topics. In this chapter Section Topics See Page A Reports 5-3 B Trend 5-12 C Status 5-14 5-2 CH 5/ View Recorded Data Section A Reports Overview Sample scaled measurement are recorded using the auto-log rate while no violations What is displayed? occur. Upon detection of a trigger violation, recording will begin at a storage rate that can reach a high speed level (see Chapter 3 Start/Setup Operations - Global Setting Menu on pages 3-4 and 3-5 for more information on data sampling and recording settings). The Reports screen display a violation in a graph or a data list. Reports enable users to customize data plots, allowing them to change and/or add parameters/channels for up to four plot displays. Zoom box features, wherein users can expand or narrow the size of a zoomed area via touch and drag, are also available for more thorough data analysis and interpretation. Users can also export data into CSV (comma separated value) format ® which can be viewed using industry-standard applications like MS Excel. The following topics are covered in this section. In this section Topic See Page Record Data Display 5-4 Record List 5-5 Record Detail 5-6 Export Data File 5-9 Plotted Parameter 5-10 5-3 Record Data Display Record Data Display From the Home screen, press Reports. Data will be available while monitoring or upon Record screen reading a stored file from the data card (see screen below). A record screen will display an activity graph of auto-log and violation data, and buttons like Detail magnification, Param to change and/or add parameters/channels to plot, and Text to display the summary list of recorded data. 1 2 4 3 5 6 MP530 7 8 9 10 Function 1 Violation start time; Parameter label or tag name; Number of frame data 2 Display record list 3 Record plot display 4 Vertical axis for parameter 5 Plot label 6 Violation start and end time; Date; Horizontal axis time/division 7 View record detail 8 Change/add channel/parameter to plot 9 Text/Graph display mode toggle 10 Return to Home screen 5-4 CH 5/ View Recorded Data Record List The list presents a summary of all captured records of violations in the order that they Record list description occurred. Each record contains a general heading indicating the time when the violation started, the parameter label or tag name, and the record duration in Frames. The procedure below describes how to access the list. View record list Action... Result... From the Home screen, press Reports. The down arrow button located on the top right section of the screen is used to access the record list. • Press the down arrow button to view the list of violations. Each entry in the list is identified by the time when the record was captured, the recorded parameter in color code, and the record duration in Frames. Entries are MP530 arranged in the order of date and time they were recorded. • Press Up/Down arrow keys to scroll the page up or down by one line or press and drag the scroll bar to move the page up or down. • Press to select (highlight) the desired record entry. • Press OK to view details of the selected record entry. MP531 • Press Cancel to ignore entry selection and return to the Reports screen. 5-5 Record Detail Record Detail MP allows users to view recorded data in detail. The Detail screen features zoom Detail screen buttons to examine the plotted data in detail. Users can resize the zoom box via touch and drag. The Detail screen also features an Export function to save the data file for ® viewing in MS Excel. Auto-scaled to display all data in the duration of the violation. Horizontal axis Auto-scaled to the minimum and maximum value. Vertical axis A detail screen is generated for each record entry. Follow these steps to view record View record detail details. Action... Result... STEP 1: From the Home screen, press Reports. Violation data must be available before it can be displayed. Use the record list to scroll through data entries. • Press Detail to use the zoom features and view data in detail. Proceed to Step 2 on page 5-7. MP530 MP535 Continued on next page 5-6 CH 5/ View Recorded Data View record detail Action... Result... (continued) STEP 2: Once the magnify button is pressed, a green box showing the default zoomed area appears. The touch screen zoom functionality allows users to select the time range of recorded data that they can zoom in. Touch any side of the zoom box to activate the drag function. Touch and drag the sides of the zoom box to expand or narrow in on data. The duration (in seconds) MP536 of record data covered in the zoom box is also displayed. Resize/move zoomed area by touching and dragging the sides of the zoom box. NOTE: The horizontal drag is locked between all graphs. This means the horizontal drag will apply consistently to all data plots. The vertical drag is independent by axis. • Once the zoom area is determined, press the Magnify button once. Proceed to Step 3 on page 5-8. MP537 Continued on next page 5-7 Record Detail, continued View record detail Action... Result... (continued) STEP 3: The magnify buttons serve as zoom function keys, each of which feature a plus sign or a minus sign within. • Press Zoom+ to display the zoomed area and view data in greater detail. Users may repeatedly zoom in on a plot for up to seven (7) levels. • Press Zoom-(n) to unzoom the display one increment at a time, where n is the counter of how MP538 many times the data has been magnified. NOTE: Data will only be displayed for channels that are enabled. • Press Back to return to the Reports screen. • Use the Text button to display the tabular min and max values over the duration of the violation that occurred. This MP530 also toggles between Text and Graph display. MP534 NOTE: The threshold values are color coded for limit conformance. Red indicates that the parameter is out of limits. Black indicates that the parameter is within limits. 5-8 CH 5/ View Recorded Data Export Data File At a touch of a button, the MP instantly stores a data file on a standard Compact Flash Saving data file memory card in CSV (comma separated value) format. The CSV format is a universally compatible ASCII text format often used to exchange data between applications without the need for special drivers or version dependent operating systems. ® MP directly exports the CSV format into MS Excel where users can do additional data manipulation and graphing. Action... Result... From the record detail screen, press Export to save the data file in memory card. Data is exported into CSV format for viewing in ® MS Excel. A message confirming that the file is saved in Excel (.xls) format appears on screen. MP535 MP539 5-9 Plotted Parameter Plotted Parameter A time plot is a graph of the value of one or more parameter over time. MP is able to What is displayed on a display time plots for individual analog, digital or calculation channels, depending on time plot? the enabled channels in input Pod. Users have the option to change and/or add parameters/channels to plot. Up to four plots with two parameters per plot can be displayed on screen. The following describes the procedure to change/add parameters to plot. View plotted parameter Action... Result... From the Reports screen, press Param. For Example: The screen shows four plots of four different parameters. The parameter labels and plots are color coded for easy association. The Plot #s appear on the left side of the screen. Users have the option to enable/disable MP530 parameters for any Plot #. The plot display area will resize according to the number of parameters enabled/disabled for display. • Press the Parameter that you want to enable for display. For parameters that are already enabled, use the Disable button to turn parameter off. MP540 For example: Disable Plot #2, Plot#3, and Plot#4. Enable CHA2 Pump Flow in Plot#1, Parameter 2. See resulting changes in plot display on page 5-11. MP540a Continued on next page 5-10 CH 5/ View Recorded Data View record parameter Action... Result... (continued) The plot display area will resize according to the number of parameters enabled/disabled for display. • Press OK to accept changes and view new plot display. • Press Cancel to ignore changes and return to the Reports screen. MP540b Resulting changes in plot display: MP542 MP543 5-11 Overview Section B Trend Overview A trend will display timeplots of auto-saved and violation (in case it is triggered) data What is displayed on a for the parameter/channel on display. trend? Users have the option to enable/disable a trend or plot display, wherein display area will resize according to the number of plots enabled for display. In addition, users have the option to enable/disable channels to trend in a select parameter. Each parameter can have one or multiple channels to plot. The trend screen also features a Zoom box, wherein users can expand or narrow in on the size of a zoomed area via touch and drag. The following topics are covered in this section. In this section Topic See Page Trend Display 5-13 5-12 CH 5/ View Recorded Data Trend Display From the Home screen, press Trend. At start-up, auto-saved data from input channels is Sample trend screen not displayed. You have to select the input channels to view trend data. The Trend screen will display buttons like Magnify for zoom features and Parameter to change and/or add channels/parameters to trend. 1 2 3 4 MP509 5 6 7 8 Function 1 Vertical axis 2 Trend plot display 3 Parameter (in user-specified label or tag name) and color code 4 Trend start and end time; Date; Horizontal axis time/division 5 Magnify to zoom in/out on plot display ® 6 Export data to MS Excel file format 7 Parameter used to change/add channel/parameter to trend 8 Return to Home screen 5-13 Overview Section C Status Overview Status presents a quick overview of the limit compliance of all active analog input, Status description numeric digital input (frequency, counter, quad encoder), and calculation channels. It also shows whether digital channels from logic inputs (reset, log trigger) are on or off. The color-coded status display provides a readout of whether or not measurement values conform to user-defined specifications. The following topics are covered in this section. In this section Topic See Page Status Display & Operation 5-15 5-14 CH 5/ View Recorded Data Status Display & Operation Status features input channels/parameters in user-specified labels or tag names. The Status display user may choose to clear or reset existing data status on the panel and restart time/date from which the panel will monitor status anew. Disabled parameters appear in gray. A parameter is considered disabled if it is not an active input channel source. Enabled parameters, on the other hand, are the active input channels configured during setup operation. The enabled parameters are color-coded to indicate limit conformance or on/off status (see text below). The Status display is active while the instrument is monitoring or by loading a previously saved file from the data card. MP570 For analog input, digital input (frequency, counter, quad encoder), and calculation parameters: Enabled parameters can have two states (Normal or Out of Limits). When monitoring, parameters that are within limits are shown in green (indicates Normal state). Those that are out of limits, exceeding Low or High threshold limits, are shown in red (indicates Out of Limits state). For digital input (reset, log trigger) parameters: Enabled parameters are monitored as being On or Off. Parameters that are in green are on. Those that are in red are off. 5-15 5-16 C H A P T E R 6 Instrument Settings Overview This chapter describes the miscellaneous tasks that users can perform to keep the MP Introduction running efficiently. These are tasks that users might perform only occasionally. The following topics are covered in this chapter. In this chapter Topic See Page Access Instrument Settings Menu 6-2 Time and Date Settings 6-3 Select Language 6-5 Set Display Preferences 6-6 Touch Screen Calibration 6-9 Turn Threshold Beeper On/Off 6-11 Format Data Card 6-12 Edit Dictionary 6-14 Reset to Factory Configuration 6-16 6-1 Access Instrument Settings Menu Access Instrument Settings Menu All functions in this chapter are found under the Instrument Settings menu. Follow Preferences menu screen these steps to display the Instrument Settings Setup Menu. Action... Result... STEP 1: Press the MP On/Off power button to turn the unit on. The Home screen will be displayed. MP001 STEP 2: Press Preferences. The Instrument Settings Setup Menu will be displayed. MP150 6-2 CH 6/ Instrument Settings Time and Date Settings Users have the option not only to set the exact time and date, but also to select the Time and Date display format of how time and date will appear on screen. Action... Result... STEP 1: From the Instrument Settings Setup Menu, press Time and Date. • Press Time if you want to change the time settings. Proceed to Step 2 on page 6-4. • Press Date if you want to change the date settings. Proceed to Step 3 on page 6-4. • Press Date Style to select the format in which you want date displayed on screen. View the MP151 three different date format selections each time you press Date Style. • mm/dd/yy format • dd/mm/yy format • yy/mm/dd format • Press Clock Style to select the format in which you want time displayed on screen. View the three different time format selections each time you press Clock Style. • analog • digital using 1 to 12 hr format (AM/PM) • digital using 1 to 24 hr format • Press OK to accept new time/ date settings and return to Instrument Settings menu. • Press Cancel to discard changes in time/date settings and return to Instrument Settings menu. Continued on next page 6-3 Time and Date Settings, continued Time and Date display Action... Result... (continued) STEP 2: Press the field representing hours, minutes, and seconds to change time settings. Use the numeric keypad to enter new time settings. Time should be entered in a 24-hour format (example: 19:00:00 for 7:00 PM). • Press OK to accept changes in time settings. • Press Cancel to discard changes in time settings. MP152 NOTE: Clock time and format can be changed anytime following this same procedure. STEP 3: Press to select the month, day, and year. Enter the year using numbers from the keypad. • Press OK to accept changes in date settings. • Press Cancel to discard changes in date settings. NOTE: Date settings and format can be changed anytime following this same procedure. MP153 6-4 CH 6/ Instrument Settings Select Language The MP menu screens appear in the English language by default. Users have the option Select language to set screen display to any of the following languages: English, Spanish, German, French, or Italian. Action... Result... From the Instrument Settings Setup Menu, press Language. • Check to select the desired language in which you want display screens to appear. • Press OK to accept new language selection. The screen will return to Instrument Settings menu. All screens will automatically change to the selected language. MP154 • Press Cancel to retain present language. 6-5 Set Display Preferences Set Display Preferences User programmable settings for the LCD screen include the backlight timer, contrast, LCD settings password protect, parameter/channel colors, and touch screen calibration. Action... Result... From the Instrument Settings Setup Menu, press Display Preferences. • Automatic backlight shutoff timer is provided for the LCD display. Press Backlight Timer to automatically turn off backlight after 1, 2, 5, 10 or 15 minutes of no user activity. Set timer to Always On if you do not want the backlight to shut off. NOTE: The auto-shutoff feature extends the life of the battery and should be duly considered. MP155 • Press Contrast to brighten/dim screen display to preferred percentage. • Press Password Protect to enable/disable password log-in code to the MP. See page 6-7 for the procedure on how to enable password protect. • Press Channel Colors to change the color of the parameter/ channel display. Select a new channel color from the color palette that will appear on screen. • Press Calibrate Touch Screen to calibrate the unit’s touch screen functionalities. See page 6-9 for the procedure on touch screen calibration. • Press Exit to return to Instrument Settings menu. 6-6 CH 6/ Instrument Settings Password protect is an optional feature that allows users to guard against unwanted Password setting access to MP. When password is enabled, only those with password privileges can access the MP touchscreen functions. Action... Result... STEP 1: Password protect is disabled by default. To enter a password, press Password Protect from the Display Preferences menu. • Select Yes if you want to turn on password protect upon resume. Proceed to Step 2. • Select No if you do not want to use password. The screen will return to Display Preferences menu. MP171 STEP 2: Enter the desired password using the keypad. A password can be written in alpha, numeric, or a combination of alphanumeric characters. No space is allowed in between characters. Up to 16 characters are allowed per password name. • Press Shift to enter a character in uppercase. • Press CAPS to enter all characters in uppercase. MP172 • Press Space to enter a space in between characters. • Press Clear All to delete the entire name on the space provided. • Press .. . .. to erase a character. • Press OK when done with password entry. Proceed to Step 3 on page 6-8. • Press Cancel to quit and return to Display Preferences menu. Continued on next page 6-7 Set Display Preferences, continued Password setting Action... Result... (continued) STEP 3: Enter the password once again for confirmation. The message Invalid Entry. Please try again. will appear when an incorrect password is entered. • Press OK to accept password confirmation. Proceed to Step 4. • Press Cancel to quit and return MP173 to Display Preferences menu. STEP 4: A password is enabled when the Password Protect is set to ON. NOTE: When password protect is enabled and the user reactivates the unit from auto-shutoff (see Backlight Timer setting on page 6-6), the keypad screen used to enter the password will appear. The user will have to enter the correct password to continue using the MP. The message Invalid Password! will appear MP174 when an incorrect password is entered. • Press Exit to return to the Instrument Settings Setup Menu. To disable the password, use the Reset to Factory Defaults function found under Instrument Setting Setup Menu. See page 6-16 for instructions on how to reset the unit to factory configurations. 6-8 CH 6/ Instrument Settings Touch Screen Calibration The MP is able to perform calibration to ensure the proper operation of the unit’s touch Calibration procedure screen functions. The calibration procedure will correct the problem of out of tolerance touch screen malfunction. Note that errors corrected by this calibration procedure are specific only to touch screen operation. Action... Result... STEP 1: From the Display Setup Menu (see page 6-6) screen, press Calibrate Touch Screen. Test if touch screen recognition operates properly by applying pressure on the LCD screen. • Press Clear to reset LCD screen and delete display markings. • Press Calib to begin touch screen calibration procedure. Proceed to Step 2. MP164 • Press Cancel to end calibration test and return to Display Setup. STEP 2: Follow the instruction Tap Center of Target to begin calibration. Target object X is initially located in the lower middle section of the screen. • A series of screens will flash showing movement of the target object: from the lower MP165 middle section to mid-right and finally to upper left section of the screen. • To end touch screen calibration, tap the center of the MP166 target object X now located in the upper left section of the screen. Proceed to Step 3 on page 6-10. MP167 Continued on next page 6-9 Touch Screen Calibration, continued Calibration procedure Action... Result... (continued) STEP 2 (continued): Once touch screen calibration is done, a message will appear to indicate Touch screen was successfully calibrated. • Press OK to continue on with calibration test verification. Proceed to Step 3. MP168 STEP 3: Test if touch screen recognition operates properly by applying pressure on the LCD screen. • Press Clear to reset LCD screen and delete display markings. • Press Accept to complete the touch screen calibration procedure. Accepting will save and store new touch screen calibration data in memory. MP169 Once the new data is stored, the old touch screen calibration data is lost. The screen will return to the Display Setup Menu. • Press Cancel to discontinue the touch screen calibration procedure. Pressing Cancel will retain the previous touch screen calibration constants, no new calibration data will be stored in memory. The screen will return to the Display Setup menu. 6-10 CH 6/ Instrument Settings Turn Threshold Beeper On/Off When threshold beeper is set to ON, the unit will beep when thresholds are crossed and Audible alarm violations occur. The beep that provides audible feedback to pressing touch screen key is not affected by this setting. Action... Result... STEP 1: From the Instrument Settings Setup Menu, press Turn Beeper On/Off. • The unit can provide audible alarm signals when triggered. Press Threshold Beeper to turn the alarm ON or OFF. • Press Exit to return to Instrument Settings menu. MP157 6-11 Format Data Card Format Data Card The Memory Card screen displays information on the card inserted in the data card slot, Format/View data card including the amount of total space, available space, and used space in card. The Memory Card screen also prompts users to set filename and format card in preparation for monitoring and writing of data. Action... Result... STEP 1: From the Instrument Settings Setup Menu, press Memory Card. • Card Status indicates status condition of the card inserted in the data card slot. The following messages may appear under Card Status (refer to pages 3-17 to 3-18 for a detailed description of each card status message): • Not Inserted • Contains File MP160 • Empty • Fragmented NOTE 1: The MP does not support file • Unformatted fragmentation. When creating a file, it will take • Invalid Card the largest continuous block and use that size block for data storage. You cannot use MP to • Card size indicates the full delete individual files from the data card. storage capacity of the data Whenever possible, transfer the files to a card. The amount of remaining computer and then reformat the card using the space and used space in data MP when there is no more space available to card are also displayed on begin new data storage. screen. NOTE 2: Refer to Chapter 3 Start/Setup • Press Format to format the Operations - Site Name/Memory Card on pages data card. Proceed to Step 2 on 3-17 to 3-20 for more information on data card page 6-13. operation. • Press View to display files stored in data card. Proceed to Step 3 on page 6-13. • Press Exit to discard changes and return to Instrument Settings menu. Continued on next page 6-12 CH 6/ Instrument Settings Format/View data card Action... Result... (continued) STEP 2: All data and setups stored in data card will be lost when you format the card. • A confirmation message verifies whether you want to continue with data card format or not. Press Yes to continue data card format. Press No to cancel data card format. • The message Format MP161 Successful indicates that data card format has been completed. Press OK to exit card format procedure and return to the Memory Card screen. MP162 STEP 3: The MP lists data file names stored in card, along with file size, time and date when data was recorded. The text color indicates the type of file: black is for data file (.ddb), green is for setup file (.set), and red is for an unknown file. • Press Up/Down arrow keys to scroll the page up or down by one line. • Press and drag the scroll bar to MP163 move the page up or down. • Press Exit to quit and return to Memory Card screen. 6-13 Edit Dictionary Edit Dictionary The dictionary displays units of measurement listed in alphabetical order. Users can Procedure refer to this list when choosing a tag label and/or engineering unit appropriate for the channel application. The dictionary is integrated in the Tag key and Legend key used to configure input channels under setup operations. Users are allowed to customize contents of the dictionary, meaning they can add new measurement unit selections or delete pre-existing ones. Action... Result... STEP 1: From the Instrument Settings Setup Menu, press Dictionary. • Press Up/Down arrow keys to scroll the page up or down by one line. • Press and drag the scroll bar to move the page up or down. • Press Add if you want to enter a new unit of measurement in the list. Proceed to Step 2. MP181 • Press Erase if you want to delete a unit of measurement from the list. Proceed to Step 3 on page 6-15. • Press Exit to return to the Instrument Settings menu. If the dictionary has been edited, a message will appear to verify if you want to save changes (press Yes) or not (press No). STEP 2: Enter a new unit of measurement using the keypad. • Press Shift to enter a character in uppercase. • Press CAPS to enter all characters in uppercase. • Press Space to enter a space in between characters. MP182 Continued on next page 6-14 CH 6/ Instrument Settings Procedure (continued) Action... Result... STEP 2 (continued): • Press Clear All to delete the entire name on the space provided. • Press .. . .. to erase a character. • Press OK when done with new entry. The new measurement unit will automatically be included in the dictionary list, arranged alphabetically. • Press Cancel to quit and return to the Dictionary Editor. STEP 3: Select the unit of measurement that you want to delete from the Dictionary Editor. • Press Erase to delete the selected unit from the list. The unit will automatically be removed from the dictionary list. MP183 MP184 6-15 Reset to Factory Configuration Reset to Factory Configuration Factory configurations are the default settings of all programmable features of the MP Definition as it left the factory. Follow these steps to reset the MP to its factory configuration. Procedure Action... Result... STEP 1: From the Instrument Settings Setup Menu, press Reset to Factory Defaults. A confirmation message verifies if you want to reset the instrument to factory configuration and lose all new data and settings. • Press Yes to erase existing settings (including user- enabled password) and reset the instrument to factory- MP156 configured setups. The screen will return to the Instrument Settings menu. • Press No to cancel. 6-16 A P P E N D I X A Optional Accessories Overview This appendix lists the optional accessories for the MP. It covers the hardware Introduction accessories available for use with MP. Topic See Page Hardware Accessories List & Descriptions A-2 To order accessories, contact Dranetz-BMI Customer Service Department at: Ordering information Dranetz-BMI Tel: (732) 287-3680 1000 New Durham Road Tel: 1-800-372-6832 Edison, NJ 08818 USA Fax: (732) 248-1834 Attention: Customer Service www.dranetz-bmi.com A-1 Hardware Accessories List and Descriptions Hardware Accessories List & Descriptions Hardware Accessory Part Number Accessories List Measurement Pods 600V Voltage Pod MP600V 300V Voltage Pod MP300V 30V Voltage Pod MP30V 20mA Current Pod MP20MA Universal Current Clamp Pod MPUC Thermocouple Pod MPUT Current Probes Current Probe Assembly, 10 to 500 A RMS TR-2500 Current Probe, 10 to 500 A TR-2500A Current Probe Assembly, 0.1 to 10 A RMS TR-2510 Current Probe, 1 to 10 A TR-2510A Current Probe Assembly, 300 to 3000 A RMS TR-2520 Current Probe, 10 to 3000 A TR-2520A Current Probe Assembly, 1 to 30 A RMS TR-2021 Current Probe Assembly, 1 to 300 A RMS TR-2019B Current Probe Assembly, 10 to 1000 A RMS TR-2022 Current Probe Assembly, 10 to 3000 A RMS TR-2023 Current Probe Assembly, 1 to 150 A RMS TR-2550A Current Probe Assembly, 1 to 1200 A RMS TR-2540A Current Probe Assembly, 1 to 300 A RMS TR-2530A Data Card Compact Flash Data Card (32 MB) MP-32M Compact Flash Data Card (64 MB) MP-64M Compact Flash Data Card (128 MB) MP-128M Compact Flash Card Reader, Parallel FLASHREADER-P Compact Flash Card Reader, USB FLASHREADER-USB Miscellaneous Hardware High Voltage Cable Set MP-HVC Soft Carrying Case MP-SCC Reusable Shipping Container MP-RSC Battery Pack, 7.2V, 2.7Ah MP-FRB External Battery Charger/UPS MP-EXB A-2 APPENDIX A/ Optional Accessories The measurement Pods act as interface between the sensor generating devices and the Measurement Pods MP. MP supports up to four Pods connected at one time. Photos and specifications of input Pods are found in Chapter 2 Input Pod Connection. MP600V Voltage Pod: Measures differential inputs up to ±600 Vdc or 0 to 600 Vac rms. Pod connections for measurement devices are via safety banana jacks. MP300V Voltage Pod: Measures differential inputs up to ±300 Vdc or 0 to 240 Vac rms. Pod connections for measurement devices are via safety banana jacks. MP30V Voltage Pod: Measures differential inputs up to ±30 Vdc or 0 to 24 Vac rms. Pod connections for measurement devices are via five-way binding posts. MP20MA Current Pod: Measures differential inputs from 4 to 20mAdc or 0 to 20 mAac rms. Pod connections for measurement devices are via five-way binding posts. MPUC Universal Current Clamp Pod: Measures differential inputs up to 1.5 Vac rms. Pod connects to the TR probe series, using Hypertronics connectors. MPUT Thermocouple Pod: Measures differential inputs from 0 to ±80m Vdc for thermocouple signals. Pod connections for measurement devices are via thermocouple mini-jacks with cold junction compensation. Several Dranetz-BMI current probes can be used with the MP: models TR2500/A, Current probes TR2510/A, TR2520/A, TR2019B, TR2021, TR2022, TR2023. Some TR current probes plug directly to the Model MPUC Universal Current Clamp Pod, while others use Hypertronics connectors to interface with the MPUC current pod TR2500, TR2510, TR2520 (TR2500A, TR2510A, TR2520A): These models will measure rms currents from 10 to 500 A, 0.1 to 500 A, 300 to 3000 A, respectively. They plug directly into the current input connectors on the MPUC current pod. These probes are not recommended for measuring medium or high frequency transients. TR2021, TR2019B, TR2022, TR2023: These probes can be used with the MP by using Hypertronics connectors. They can measure rms currents in ranges of 1 to 30 A, 1 to 300 A, 10 to 1000 A, and 10 to 3000 A, respectively, and are needed to accurately measure medium and high frequency transients. A-3 Hardware Accessories List & Descriptions, continued Compact Flash Data Card: MP supports the use of Compact Flash cards in its native Data card format, without the need for PC card adapter. Compact Flash cards are available in three sizes: 32MB, 64MB, and 128MB. Compact Flash Card Readers: Two types of card readers are available for easy data manipulation and data transfer from the Compact Flash card to the computer: via USB port (FLASHREADER-USB) or via parallel port (FLASHREADER-P). Soft Carrying Case: Heavy-duty, padded, nylon carrying case. Includes pockets for Miscellaneous hardware cable set, current probes, and other accessories. Reusable Shipping Container: Lockable, high-impact plastic case with foam insulation for protecting the instrument during shipping. Battery Pack: NiMH (Nickel Metal Hydride) battery cells are used in MP. See Appendix C Battery Specifications and Replacement Procedure. External Battery Charger: The MP-EXB charges a battery pack while the instrument is in use. A-4 A P P E N D I X B Technical Specifications Overview The following specifications are covered in this appendix. In this appendix Topic See Page General B-2 Interfaces B-3 Input Parameters B-4 Calculated Parameters B-6 B-1 General General Size: 12” Width x 2.5” Height x 8” Depth (30 x 6.4 x 20.3 cm) Dimensions Weight: 4.2 lbs. (1.9 kg) Operating: 0 to 50 °C (32 to 122 °F) Environmental NOTE: MP300V and MP600V operating range ±5 to 50 °C (41 to 122 °F) Storage: -20 to 55 °C (4 to 131 °F) Humidity: 95% non-condensing Altitude: 2000 m (6560 ft) maximum Intended Use: Indoor Crystal controlled; 1 second resolution System Time Clock Event time clock displays to 1 msec resolution Time displayed in analog or digital (12 or 24 hour) format Accurate to 60 seconds per month Sizes range from 32MB to 256MB Compact Flash Data Card Use ONLY the external power supply provided with the unit for operation and battery Power Requirements charging. Use of any other power supply is not recommended. Voltage: 90-264V AC, 47-63 Hz Consumption: 20 watts maximum Field replaceable batteries: More than 2 hours run-time (3 hours typical) when fully charged. B-2 APPENDIX B/ Technical Specifications Interfaces Mains supply: Installation Category II, Pollution Degree 2 Installation Categories Measurement inputs: Installation Category III, Pollution Degree 2 Type: 1/4 VGA color graphic, touch screen Liquid Crystal Display (LCD) with Display compact fluorescent (CCFL) backlighting. Programmable backlight time-out to reduce power consumption. Reactivates with touch. Resolution: 320 x 240 dot matrix Size: 3.75 x 4.75 inches Audible alarm of short (approximately 0.1 second) or long (approximately 1 second) Alarm duration to call attention to an error condition or violation trigger, respectively. Connect to the MP mainframe using the following external Pod interface: MP600V Connection Voltage Pod, MP300V Voltage Pod, MP30V Voltage Pod, MP20MA Current Pod, MPUC Universal Current Clamp Pod, and MPUT Thermocouple Pod. B-3 Input Parameters Input Parameters Up to four external Pods can connect to either Channels A, B, C or D. Each Pod has Analog Inputs four DC-coupled differential analog inputs of the same type. Analog inputs are sampled at 10kHz rate. Pod type: MP600V Voltage Pod Operating Range (Differential and Common-Mode): ±0 to 600 Vdc or 0 to 600 Vac RMS Resolution: Tenths of a volt Input impedance: 16 MΩ (differential); 8 MΩ (common mode) Accuracy: ±0.1% Full Scale up to 400 Hz; ±0.5% Full Scale up to 3 KHz; ±1% Full Scale up to 6 KHz Connection: Safety banana jacks Identification: EEPROM for Pod ID and storage of calibration values Pod type: MP300V Voltage Pod Operating Range (Differential and Common-Mode): ±0 to 300 Vdc or 0 to 240 Vac RMS Resolution: Hundredths of a volt Input impedance: 40 MΩ (differential); 10 MΩ (common mode) Accuracy: ±0.1% Full Scale up to 400 Hz; ±1.0% Full Scale up to 6 KHz Connection: Safety banana jacks Identification: EEPROM for Pod ID and storage of calibration values Pod type: MP30V Voltage Pod Operating Range (Differential and Common-Mode): ±0 to 30 Vdc or 0 to 24 Vac RMS Resolution: Millivolts Input impedance: 4 MΩ (differential); 1 M Ω (common mode) Accuracy: ±0.1% Full Scale up to 400 Hz; ±1.0% Full Scale up to 6 KHz Connection: Five-way binding posts Identification: EEPROM for Pod ID and storage of calibration values Pod type: MP20MA Current Pod Operating Range (Differential and Common-Mode): 4 to 20m Adc or 14m Aac RMS Resolution: Microamps Input impedance: 250Ω (differential); 1 M Ω (common mode) Accuracy: ±0.1% Full Scale up to 400 Hz; ±1.0% Full Scale up to 6 KHz Connection: Five-way binding posts Identification: EEPROM for Pod ID and storage of calibration values Continued on next page B-4 APPENDIX B/ Technical Specifications Pod type: MPUC Universal Current Clamp Pod Analog Inputs (continued) Operating Range (Differential): 1.5 Vac RMS = Rated full scale of probe; Crest Factor: 2 Resolution: Dependent on clamp probe Accuracy: Dependent on clamp probe (typically 1 to 3% for inputs greater than 10% of full scale) Connection: Hypertronics connectors for TR series current probes Pod type: MPUT Thermocouple Pod Thermocouple Types Supported: Accepts types B, E, J, K, N, R, S, and T Operating Range: -10m V to +80m Vdc Resolution: 0.1 degree Input impedance: 10 MΩ (differential); 1 MΩ (common mode) Accuracy: ±0.1% Full Scale DC Cold Junction Reference: Digital temperature sensor for cold junction compensation Connection: Mini jacks Identification: EEPROM for Pod ID and storage of calibration values Available in all four Pod types. Each Pod has two digital inputs. Digital inputs are Digital Inputs sampled at 40kHz rate. Minimum Time Interval (for timed inputs): 1 msec VL: 0 to 0.6 Vdc VH: 4.5 to 30 Vdc IIN: -3 mA min for logic True RIN: 1.2 kΩ @ Vcc = 5 Vdc Isolation: Optically isolated to 750 Vac RMS, common mode Connection: Five-way binding posts Software-selectable hysteresis debounce when digital inputs are used as logging triggers. Digital inputs can be configured as: • Reset • Logic Trigger • Frequency measuring • Counter • Quadrature Encoder B-5 Calculated Parameters Calculated Parameters Calculates are math functions that can be applied to one or two channels that can either Calculation formulae be analog, digital or another calculate. Values for the following inter-channel calculation formulae are user-programmable. CLC x = m (CHN y) + b CLC x = (CHN y)/ m + b CLC x = m (CHN y + CHN z) + b CLC x = m (CHN y - CHN z) + b CLC x = m (CHN y) (CHN z) + b CLC x = (CHN y) (CHN z)/ m + b CLC x = (CHN y) / (CHN z) m + b CLC x = m (CHN y) / (CHN z) + b CLC x = m / (CHN y) + b CLC x = m (SQR CHN y) + b CLC x = m (ABS CHN y) + b CLC x = m (MAX CHN y) + b CLC x = m (MIN CHN y) + b CLC x = m (AVG CHN y) + b MP allows a total of eight channels for inter-channel calculations. Calculations are for readability purposes and are not stored with live data. B-6 A P P E N D I X C Battery Specifications and Replacement Procedure Overview The internal battery pack used in MP functions as the primary power source and UPS. Introduction Always charge the battery fully before using the unit. The MP will fully charge its internal battery in six (6) hours. MP uses a non-volatile flash memory for backup that is not operator replaceable. Data will not be lost if the battery pack is removed. The flash memory will store data temporarily. The following topics are covered in this appendix. In this appendix Topic See Page Battery Specifications C-2 Battery Safety Precautions C-3 External Battery Charger C-4 Battery Pack Replacement C-6 C-1 Battery Specifications Battery Specifications Battery pack Type: Sealed, rechargeable NiMH (Nickel Metal Hydride) cells. Location: Battery compartment on the rear of the unit. Number of batteries in pack: 6 Voltage: 7.2 V dc Capacity: 2.7 Ah Charging: A depleted battery pack can be recharged in approximately six (6) hours. Length of operation: More than two (2 ) hours when fully charged and with backlight on. When backlight is turned off, the unit can run continuously for more than three (3) hours. Suggested replacement interval: Two years Part Number: MP-FRB NOTE: The length of time that the MP can operate on the battery pack degrades over the life of the batteries and the number of charge/discharge cycles. Size: 2 3/8" Width x 6" Height x 4 1/2" Depth (30 x 6. 4 x 20.3 cm) Dimensions Weight: 1.5 pounds (0.7 kg) Operating: 0 to 50 °C (32 to 122 °F) Environmental Storage: -20 to 55 °C (4 to 131 °F) Humidity: 0 to 95% non-condensing; indoor use Altitude: 2000 m (6560 ft) maximum Installation Category: Category II, Pollution Degree 2 Voltage: 90 - 264V AC, 45 - 66 Hz Power requirements C-2 APPENDIX C/ Battery Specifications and Replacement Procedure Battery Safety Precautions DO NOT intentionally short circuit the battery pack. The batteries are capable of WARNING providing hazardous output currents if short circuited. The MP is equipped with an internal battery charger circuit. Do not attempt to charge the batteries with an external charger other than the Dranetz-BMI battery charger, since improper charging could cause battery explosion. NO ponga intencionalmente la bateria en cortocircuito. Las baterias son capaces ADVERTENCIA de proporcionar corrientes de salida peligrosas si est·n en cortocircuito. La MP esta equipada con un circuito interno cargador de baterÌas. No intente cargar las baterÌas con un cargador externo que no sea el cargador de baterias Dranetz- BMI, puesto que la carga indebida podrÌa hacer que explote la bateria. AVERTISSEMENT NE PAS court-circuiter délibérément le bloc-batterie. Lors díun court-circuit, les batteries risquent díémettre des courants effectifs dangereux. MP posséde un circuit de chargeur de batterie intégré. Ne pas tenter de charger les batteries au moyen díun chargeur externe autre que le chargeur de batterie Dranetz-BMI, car un rechargement fautif pourrait entrainer l’explosion de la batterie. Die Batterien dürfen NICHT kurzgeschlossen werden. Im Falle eines WARNUNG Kurzschlusses konnen die Batterien lebensgefährliche Ausgangsstrome leiten. MP ist mit einem internen Batterieladegerät ausgestattet. Die Batterien sollten nur mit dem Ladegerät von Dranetz-BMI geladen werden. Die Verwendung eines externen Ladegeräts kann zu einer Explosion der Batterien führen. Observe the following precautions when inspecting or replacing the battery pack: Safety precautions • Do not attempt to replace individual batteries of the pack or substitute other battery types. • Do not dispose of battery in fire. • Dispose of a used battery promptly in accordance with local Environmental Protection Agency (EPA) regulations. • Visually inspect the battery pack for corrosion. The batteries have a safety pressure vent to prevent excessive gas build-up and corrosion indicates that venting has occurred. Possible causes of venting are: a defective charger, excessive temperature, excessive discharge rate, or a defective cell. If corrosion is excessive, the battery pack may require replacement (contact Dranetz- BMI Customer Service Department). C-3 External Battery Charger External Battery Charger The External Battery Charger for the MP bears the part number MP-EXB and is Description available as an optional accessory. Charging the battery pack(s) is especially useful when monitoring for short durations, where no standard 115 or 230 VAC power is available. Having multiple charged battery packs can provide power to the unit for several hours, allowing users to perform monitoring analysis in remote locations. NOTE: The battery charger is only operational for charging a single battery pack. It will not power the unit or charge the unit’s internal battery. Do not connect the charger to the MP and then operate the unit since the battery pack will become discharged if the unit is in a powered “ON” state. Also, if the unit is in an “OFF” state, it will not charge the internal battery pack. C-4 APPENDIX C/ Battery Specifications and Replacement Procedure The following procedure describes the basic operation of the MP-EXB battery charger Charger operation and its applications. 1. Insert the MP-FRB battery pack with the proper polarity into the MP-EXB battery charger. 2. Configure the AC power plug of the battery charger by sliding the proper plug supplied (US, Euro, UK or Australia) and locking it into place. Next, plug the AC power plug of the battery charger to the proper power source: 120 VAC for US plug or 230 VAC for Euro, UK, or Australia type plug. 3. Allow the battery to charge for a minimum of six (6) hours before use. NOTE: The battery charger indicator glows steadily while charging, and flashes when the battery pack is fully charged. 4. After the 6-hour charge period, the battery pack can be removed from the charger and used for unit operation. If the battery is left in the charger, it will remain fully charged. C-5 Battery Pack Replacement Battery Pack Replacement The MP contains an easily replaceable internal battery pack. See Appendix D for Introduction ordering information. Replace with Dranetz-BMI NiMH battery pack MP-FRB only. WARNING Reemplace con batería Dranetz-BMI NiMH MP-FRB solamente. ADVERTENCIA AVERTISSEMENT Remplacer par la batterie Dranetz-BMI NiMH MP-FRB exclusivement. Nur mit Dranetz-BMI NiMH MP-FRB Batteriesatz auswechseln. WARNUNG During normal operation, the battery pack will be slightly warm to the touch. NOTE Follow these steps to replace the battery pack. Procedure Step Action 1 Press the MP power button to off. 2 Turn off power to the circuit being measured. 3 Disconnect voltage and current probes from the circuit and the MP’s rear panel. 4 On the bottom of the MP, push the tab to release the battery cover. Refer to the diagram shown on page C-7. 5 Remove the cover. 6 Pull up on removal strap and remove battery pack. 7 Insert the new pack into the compartment making sure to observe polarity markings. 8 Replace the cover and press down until it latches closed. 9 Discard the old battery pack in accordance with Environmental Protection Agency (EPA) regulations. 10 Press the MP power button to on. Continued on next page C-6 APPENDIX C/ Battery Specifications and Replacement Procedure Battery removal diagram C-7 C-8 A P P E N D I X D User Replaceable Parts List The following parts are easily replaced by the operator and do not require special tools Introduction or access to the interior of the unit. Call Dranetz-BMI Customer Service at (732) 287-3680 or 1-800-372-6832 to order any To order parts of the following parts. Parts List Part Description Part Number AC Adapter/Battery Charger MP-EXB Battery Door 116037-G1 Battery Pack MP-FRB Rubber Skin for MP 116035-G4 High Voltage Cable Assembly MP-HVC (See below for separate parts) (116042-G5) Measurement cable set, parts Part Description Quantity Part Number list 4MM Plug, 1000V Silicone Cable, Red 1 900366 4MM Plug, 1000V Silicone Cable, Yellow 1 900367 4MM Plug, 1000V Silicone Cable, Blue 1 900368 4MM Plug, 1000V Silicone Cable, Gray 1 900369 4MM Plug, 1000V Silicone Cable, White 4 900370 Alligator Clip, 4MM Plug-on, Red 4 900371 Alligator Clip, 4MM Plug-on, Black 4 900372 Cable Pouch 1 116043-G1 D-1 D-2 A P P E N D I X E MP Menu Structure The MP menu screen maps are shown in the following pages. Use the Level number Menu structure description and Heading as guide to navigate through the different menu screens. Each screen contains touch screen buttons which lead to related functions. In this appendix The following screen maps are shown in this appendix. Level No. Heading See Page 001 Home Screen E-2 100/1(a) Start Menu - Setup Wizard E-3/a 100/1(b) E-3/b 100/2 Start Menu - Monitor using present setup E-4 100/3 Start Menu - Load setup from card E-5 100/4 Start Menu - Load data from card E-5 150 Instrument Settings E-6 200 Scope Mode E-7 300 Meter Mode E-8 220 DFT E-9 240 Graph E-10 400 Trend E-11 430 Reports E-12 440 Report Parameters E-13 470 Status E-14 E-1 LEVEL 001 Home Screen To Level 300 To Level 220 MP300b MP226 To Level 200 To Level 240 MP201b MP243 MP002 MP509 MP150 To Level 150 To Level 400 MP530 MP100 MP570 To Level 100/1 To Level 430 To Level 470 E-2 MP100 LEVEL 100/1(a) Start Menu - Setup Wizard MP101 MP102 To Level 001 MP103 MP109 MP104 MP112 MP105 MP110 MP113 MP115 cont. next page MP114 E-3/a LEVEL 100/1(b) Start Menu - Setup Wizard MP116 MP117 MP121 MP120 MP118 MP123 MP122 MP119b To Level 100/2 E-3/b LEVEL 100/2 MP100 Start Menu - Monitor Using Present Setup MP125 MP126 To Level 001 MP131 MP127 MP132 MP135 MP129 MP133 MP136 MP130 MP113 MP126 MP134 MP126 MP138 E-4 LEVEL 100/3 Start Menu - Load Setup from Card MP100 MP140 To Level 001 MP141 LEVEL 100/4 Start Menu - Load Data from Card MP100 MP142 To Level 001 E-5 LEVEL 150 MP150 Instrument Settings MP157 MP151 MP154 MP160 MP155 MP181 MP156 E-6 LEVEL 200 Scope Mode MP200 MP201 MP205 MP208b MP202 MP206 MP209 MP203 MP207 MP210 MP204 E-7 LEVEL 300 Meter Mode MP300 MP301 MP302 E-8 MP220 LEVEL 220 DFT MP221 MP229 MP222 MP225 MP230 MP223 MP226 MP224 MP227 E-9 LEVEL 240 Graph MP240 MP241 MP244 MP242 MP245 MP243 MP246 E-10 MP400 LEVEL 400 Trend MP509 MP401 MP509b MP402 MP510 MP403 MP511 MP404 E-11 MP430a LEVEL 430 Reports MP434 MP430 MP431 use scroll bar or up/down arrow keys to MP435 sort through record list, then press to select (highlight) desired violation entry TO LEVEL 440 MP439 MP436 touch/drag zoom box to desired proportion MP437 MP438 E-12 LEVEL 440 Report Parameters MP430 MP540 MP540a MP540b MP542 MP543 E-13 LEVEL 470 Status MP570 E-14

Thank you for viewing our pdf. To View the formatted version download it now

Download Now
How to Buy
Dranetz products are sold direct from Dranetz, as well as via Sales Reps and Distributors worldwide.
Buy now!
Not ready to buy? Get more info.
Try it before you buy it
Make sure you are buying the right tool for the job. Schedule a personal Dranetz product demo at your location, at your convenience.
Schedule a Demo