Encore Series: Brochure Specifications page

We are happy to provide this downloadable file for your convenience. Please provide us with some basic information so that we may better address your needs now and in the future. Please enter your email address carefully as this will be where we send the download link. Dranetz respects your privacy. Your contact information will not be sold or rented. Only Dranetz or its authorized sales partners may use this information.

ENCORE SERIES / 61000 SYSTEM SPECIFICATIONS VOLTAGE MODULES POWER QUALITY TRIGGERS 1 • Channels: (4) differential inputs, AC/DC • V & I RMS (Sag/Dip, swell, interruption) 1 cycle resolution, ⁄2 cycle steps as per IEC61000-4-30 • Sampling: 512 samples/cycle, 16bit A/D, synchronous sampling. Range: 1-600 Vrms, +/- 1000VPK - Reference: L-L, L-N • Frequency: 16/20Hz, 50Hz, 60Hz, 400Hz (optional) - Pre/Post cycles : 30 pre (max), 10,000 post (max) • Full Scale Accuracy: 0-600V 0.1% reading +/- 0.05% full scale, 7KHz bandwidth for • Transients: low/medium frequency transients - Waveshape Triggers: Cycle by cycle, RMS deviation 100-300V AC 0.1% reading for IEC61000-4-30 - High speed transients (optional) • Input impedance: 10MΩ to ground - Peak transient • Choice of connections: Screw terminals, safety connectors, D connector for use with (optional) remote pod with screw terminals. Choose one. • Journals (stored parameters): High, low, very-high, very-low • Optional: Anti Aliasing filters MEASURED PARAMETERS (NOT LIMITED TO THE FOLLOWING) • Optional: High Speed transients (total of 2 slots) • Power - Sampling: 1MHz - V, I, W, VA, VAR, TPF, DPF, Demand, Energy, etc. - Accuracy: +/-10% reading, +/- 0.5% full scale • Harmonics/Interharmonics/Distortion (per IEC61000-4-7) CURRENT MODULES - Harmonics individual harmonic spectrum to the 63rd for V & I • Channels: (4) differential inputs, AC/DC - Vthd, Ithd, Vtid, Itid, K factor, TDF, TIF, more • Sampling 512 samples/cycle, 16 bit A/D. Range: Full scale current = 1.5Vrms, crest factor of 3 - 5 user specified frequencies • Accuracy: 0.1% reading +/- 0.05% full scale, 3KHz bandwidth for low/medium freq. transients. - Unbalance: Symmetrical components, worst from ave. Does not include CT. • Flicker (per IEC61000-4-15, IEEE1453): Pst, Plt, sliding Plt • Choice of connections: TR connectors, D connector for use with (optional) remote 5A or 1A pod with screw terminals or 5A/20X pod with feed through tubes. Choose one. COMMUNICATIONS: • Optional: Anti Aliasing filters • 10/100BaseT Ethernet, RS232, RS485, USB (future functionality) • Optional High Speed transients • Optional GSM/GPRS, Analog modem - Sampling: 1MHz • Protocols: XML, Modbus TCP/RTU, HTTP - Accuracy: +/-10% reading, +/- 0.5% full scale • Time synchronization: NTP, optional GPS USER INTERFACE VOLTAGE TRANSDUCER INPUT MODULE • Remote: Web browser via Encore Series Software:. Primary UI for setup, trends, reports, real • Channels: (4) differential inputs, DC coupled time. Available languages; English, Spanish, French, German, Italian. Instrument web • Sampling: 100KHz. Range: 0-24VDC browser for metering. English only. • Accuracy: 0.1% reading +/- 0.05% full scale plus transducer accuracy 1 • Optional Local Display: ⁄4 VGA touch screen remote display, rack mounted display. Languages: 12 • Input impedance: >100KΩ to ground GENERAL SPECIFICATIONS • Connections: Screw terminals • Size (HxWxD): 4" x 11" x 8" (10.2cm x 28cm x 20.3cm), Weight: 4.2 pounds (1.9 kg) CURRENT INPUT TRANSDUCER INPUT MODULE • Operating Temperature: -10º to 60º C • Channels (4) differential inputs, DC coupled • Storage Temperature: -40º to 85º C • Sampling: 100KHz. Range: 4-20ma • Humidity: 10 to 95% non-condensing • Accuracy: 0.1% reading +/- 0.05% full scale plus transducer accuracy • System Time Clock-Crystal controlled-1 ms resolution • Connections: Screw terminals • Power supply: 12VDC - 15 minute internal UPS DIGITAL INPUT MODULE - AC supply: 90-264 VAC 47-63 Hz • Channels: (8) - Optional 125VDC, 220VDC, 48VDC • Sampling: 1KHz. Range: 0-135V AC/DC • Memory 1GB, internal • Triggers: Edge, level • Connections: Screw terminals SYSTEM CONTROLLER • Industrial grade computing platforms: InfoNode model 5502 (CF memory), RELAY OUTPUT MODULE 5504 (hard disk). Choose one. • Channels: (4) MISCELLANEOUS OPTIONS • Max voltage 250VAC/DC • Enclosures: Weather resistant, rack, wall, switchgear • Type: Form C • CT’s: Clamp-on, split core, solid core, flex, DC MONITORING/COMPLIANCE • IEC61000-4-30 Class A, IEC61000-4-7, IEC61000-4-15 • EN50160, NVE, IEEE1159, IEEE1453, IEEE519, IEEE1459 • IEC61000-3-6/7 REVENUE ACCURACY • ANSI C12 - ANSI C12.1 Accuracy compliant - ANSI C12.20.0.2 compliant • IEC - IEC 60687 0.2S compliant - IES 60687 accuracy class 0.5S compliant 1.800.372.6832 sales@dranetz-bmi.com tel 732.287.3680 • fax 732.248.1834 • 1000 New Durham Road • Edison, New Jersey 08818 • USA ENCORE Series, PQVIEW and DRAN-VIEW are trademarks of Dranetz-BMI. ©2005 Dranetz-BMI. All rights reserved. dranetz-bmi.com Printed in the United States. Specifications are subject to change without notice.

Thank you for viewing our pdf. To View the formatted version download it now

Download Now
How to Buy
Dranetz products are sold direct from Dranetz, as well as via Sales Reps and Distributors worldwide.
Buy now!
Not ready to buy? Get more info.
Try it before you buy it
Make sure you are buying the right tool for the job. Schedule a personal Dranetz product demo at your location, at your convenience.
Schedule a Demo