DranTech Xtra/Pro Brochure

We are happy to provide this downloadable file for your convenience. Please provide us with some basic information so that we may better address your needs now and in the future. Please enter your email address carefully as this will be where we send the download link. Dranetz respects your privacy. Your contact information will not be sold or rented. Only Dranetz or its authorized sales partners may use this information.

DranTech XTRA/PRO TRMS Digital Multimeters • Digital Hand-Held Multimeter with RMS Measurement: VAC TRMS, VAC+DC TRMS, VDC, Hz (V), Hz (A), Ω, V , °C/°F (TC) • 4 ¾ -digit display (60.000 counts), with backlit display • Direct Current measurement with increased accuracy and Current measurement, via current clamp transformer and sensors • Data Storage of Min-Max Values • Automatic or Manual Measuring Range Selection • Analog Scale for Quick Trend Indication – Bar Graph or Pointer • Rugged with Protective Rubber Holster XTRA only : remote configured, and momentary and stored measurement data via the bidirectional infrared Interface with DranWin software Selectable Filter for V AC Measurement Applications A 1 kHz low-pass filter can be activated if required, for These digital multimeters are suitable for universal use in example when measuring motor voltage at electronic electrical engineering, electrical installation, laboratory frequency converters. applications, telecommunication, technical training, as well as for troubleshooting in the field. Battery Capacity Indication – Power Saving Circuit The battery load capacity is indicated on the display. If Features user selected, the device is switched off automatically if the measured value remains unchanged for a period of Three Connector Terminals with patented Automatic between 10 and 59 minutes (adjustable), and if none of Blocking Sockets * the controls are activated during this time. All current ranges are implemented via a single connector socket which prevents any possibility of operator error. DKD Calibration Certificate Beyond this, the automatic blocking sockets prevent Multimeters are furnished with an internationally accepted incorrect connection of the measurement cables, as well DKD calibration certificate (recognized by EA and ILAC). as selection of the wrong measured quantity. Danger to After the specified calibration interval has elapsed the user, the instrument and the device under test (recommended interval: 1 to 3 years), the multimeters resulting from operator error is therefore eliminated. can be inexpensively recalibrated by any calibration * Patented (patent no. DE 40 27 801 C2 and US 5,166,599) laboratory. Overload Protection Scope of Delivery The instrument is safeguarded for up to 1000 V in all • Multimeter with 1 pair of safety test leads (1.5 m) measuring functions by overload protection. Voltages of with 4 mm diameter, 1000 V CAT III, 600 V CAT greater than 1000 V and current of greater than 10 or 16 IV (KS17-2) A are indicated acoustically. • 2 alkaline batteries, 1.5 V, type AA RMS Value with Distorted Waveforms • CD with operating instructions, The measuring method applied allows for waveform • DKD calibration certificate independent RMS measurement (TRMS AC and AC+DC) • Pack of 10 superfast Fuses 10A/1kV for voltage and current up to 10 kHz). • HC20 Hardcase Applicable Regulations and Standards IEC 61010, Safety requirements for electrical Background illumination is switched off approximately Part 1:2001 equipment for measurement, 1 minute after it has been activated (backlit display) control and laboratory use IEC 61326 Electrical equipment for control technology and laboratory use – EMC requirements Analog IEC 60529 Test instruments and test Display LCD scale with bar graph or pointer, procedures – degrees of protection provided depending on the selected parameter by enclosures (IP code) setting Scaling With 4 division lines each, 1 bar/pointer corresponds Warranty to 500 digits at the digital display Polarity display In auto-ranging mode 24 months for materials and workmanship With the symbol Overflow display 1 to 3 years for calibration (depending upon application) Update rate 40 measurements per second and display refresh Internal Clock Digital Time format DD.MM.YYYY hh:mm:ss Display/char 7-segment characters / 15 mm Resolution 0.1 s height Accuracy ±1 min. per month Resolution 4 ¾ digits, 60,000 counts Temperature Influence 50 ppm/K Overflow display “OL” is displayed for ≥60,000 Power Supply Polarity display “–” (minus sign) is displayed if pos. Battery 2 ea. 1.5 V, size AA, lead is connected to “ ” alkaline manganese per IEC LR6 Measuring rate 10 and 40 measurements per (2 ea. 1.2 V NiMH rechargeable battery possible) second with the Min-Max function Service life with alkaline manganese: approx. 200 hours except for the capacitance, Battery test: Battery capacity display with battery symbol in 4 segments: . frequency and duty cycle Display of momentary battery voltage via menu measuring functions function. Power OFF function: Multimeter is switched off automatically: Refresh rate 2 times per sec., every 500 ms – If battery voltage drops to below approx. 1.8 V – If none of the keys or the rotary switch are activated for an adjustable duration of 10 to 59 minutes, and the Acoustic Signals multimeter is not in continuous operating mode For voltage: Intermittent signal at above 1000 V For current: Intermittent signal at above 10 A Fuse Continuous signal at above 16 A Fuse FF (UR) 10 A/1000 V AC/DC; 10 mm x 38 mm, Electrical Safety Switching capacity: 30 kA at 1000 V AC/ DC, protects the current measurement input in the 100 μA through 10 A Per IEC 61010-1:2001 ranges Cat. III 1000 V - Cat. IV 600 V Test voltage 6.7 kV~ Display LCD panel (65 mm x 36 mm) with analog and digital display including unit of measure, type of current and various special functions Electromagnetic Compatibility EMC Ambient Conditions (to meet all specs) Interference IEC 61326: May 2004, class B Accuracy range 0 °C ... +40 °C emission Interference IEC 61326: May 2004, appendix E Operating temp. -10° C ... +50° C immunity range IEC 61000-4-2: Dec. 2001 Storage temp. range -25° C ... +70° C (w/o batteries) Feature B 8 kV atmospheric discharge Relative humidity Max.95%, no condensation 4 kV contact discharge allowed IEC 61000-4-3: Dec. 2001 Elevation To 2000 m Feature A 3 V/m Deployment Indoors, except within specified ambient conditions Mechanical Design Housing Impact resistant plastic (ABS) Dimensions 200 x 87 x 45 mm (without protective rubber holster) Weight Approx. 0.35 kg with batteries Protection Housing: IP 52 Specifications Specifications (cont’d) ` Data Interface Type Optical via infrared light through the housing Data transmission Serial, bidirectional (not IrDa compatible) Protocol Device specific Baud rate 38,400 baud Functions – Select/query measuring functions and parameters – Query momentary measurement data --Read out stored measurement data The USB plug-in interface adapter (see accessories) is used for adaptation to the PC’s USB port. Internal Measured Value Storage (XTRA only) Memory capacity 4 MBit / 540 kB for approx. 15,400 measured values with date and time stamp 1.800.372.6832 sales@dranetz-bmi.com tel 732.287.3680 : fax 732.248.1834 1000 New Durham Road, Edison, New Jersey 08818 USA © 2008 Dranetz-BMI. All rights reserved. www.dranetz-bmi.com Printed in United States. Specifications are subject to change without notice. DranTech PRO/XTRA Rev 1-March-08

Thank you for viewing our pdf. To View the formatted version download it now

Download Now
How to Buy
Dranetz products are sold direct from Dranetz, as well as via Sales Reps and Distributors worldwide.
Buy now!
Not ready to buy? Get more info.
Try it before you buy it
Make sure you are buying the right tool for the job. Schedule a personal Dranetz product demo at your location, at your convenience.
Schedule a Demo