DranTech Ultra Brochure
We are happy to provide this downloadable file for your convenience. Please provide us with some basic information so that we may better address your needs now and in the future. Please enter your email address carefully as this will be where we send the download link. Dranetz respects your privacy. Your contact information will not be sold or rented. Only Dranetz or its authorized sales partners may use this information.
DranTech ULTRA Precision Digital Multimeter Bench DMM in a Hand-Held Housing • Precision multimeter (V, mA, Ù, Hz, °C/°F) and data logger • 1,200,000 digit display, 6 ½ digit High resolution for: DC/AC+DC voltage: 100 nV/1microV DC and AC+DC Current: 100 picoA • TRMS AC+DC • Milliohmmeter with 2 and 4-wire connection Resolution: 0.1 mOhm Kelvin Connection • Precision temperature meter, °C and °F for Pt100/Pt1000 sensors with 2/4-wire connection, Resolution: 0.01 °C/°F for J and K thermocouples, resolution: 0.1 °C/°F, internal or external reference junction can be selected • Large data memory: 128 kB • DKD Calibration Certificate included • Automatic or Manual Measuring Range Selection Applications The ULTRA multimeter is a high performance, precision Overload Protection measuring instrument for R&D labs, industrial The instrument is safeguarded against overloading in all applications, universities, government authorities, measuring functions. All current measuring ranges are testing stations, manufacturing and QA. With a display equipped with a self-resetting, electronic fuse. range of 1,200,000, as well as exceptional accuracy and long-term stability, it fulfills all of the demands of Averaging Filter for Noisy Measurement calibration and R&D labs. A digital filter (1/2/4/8/16 measurement values) is used to smooth noisy measurement signals. Features Battery Charging Status – Power Saving Circuit True RMS Measurement of Distorted Waveforms Battery operation allows for mobile use of the The measuring method applied allows for waveform instrument for demanding maintenance work and independent RMS measurement for voltage and calibration tasks. An optional mains power pack can be current up to 100 kHz at crest factors of up to 10. utilized for stationary, long-term operation. If user selected, the device is switched off automatically if the Sampling Rate measured value remains unchanged for a period of The sampling rate determines the interval at which the between 10 and 59 minutes (adjustable), and if none of respective measurement value is saved to memory. the controls are activated during this time. Depending upon measured quantity and resolution, the interval can be set within a range of 0.01 s to 60 s. DKD Calibration Certificate The multimeters are furnished with an internationally Storing MIN-MAX Values to Memory accepted DKD calibration certificate (recognized by EA In addition to displaying the current measurement value, and ILAC). After the specified calibration interval has the minimum or maximum value can be continuously elapsed (recommended interval: 1 to 3 years), the updated and stored to memory at the selected sampling multimeters can be inexpensively recalibrated by any rate. calibration laboratory. Memory Mode Internal Clock The instrument is equipped with a 128 kB data memory with backup battery. The memory can be devided in 1 to Time format DD.MM.YYYY hh:mm:ss 15 blocks. New values can be written to memory, even Resolution 0.1 s after completion of a given measurement without loss of data, until the maximum capacity of 30,000 Accuracy ±1 min. per month measurement values is used. The data can be stored to Temperature Influence 50 ppm/K intermediate memory. The system records measurement values in relative time. Depending upon the measured quantity, the interval can Power Supply be set in steps of 10 ms, 100 ms, 1 s, 10 s and 60 s. Individual measurement values can also be saved to Battery 2 ea. 1.5 V, size AA, memory by pressing a key. alkaline manganese per IEC LR6 Service life: approx. 16 hours Measuring Cycle Battery test: Battery capacity display with battery Measuring Interval Depending upon Resolution symbol Function 1 200 000 120 000 12 000 1 sec 0.1 sec 0.01 sec V & I dc Power OFF function: Multimeter is switched off automatically 1 sec 0.1 sec 0.01 sec V & I ac – If battery voltage drops to below approx. 1.8 V 1 sec 0.1 sec 0.01 sec Ohms – If none of the keys or the rotary switch are activated 1 sec 0.1 sec 0.01 sec Temp for an adjustable duration of 10 to 59 minutes, and the 1 sec 0.1 sec 0.01 sec Freq multimeter is not in the continuous operation mode Scope of Delivery Fuse • Multimeter with protective rubber holster, 1 pair of safety test leads (1.5 m) with 4 mm All current measuring ranges are protected by an diameter, 1000 V CAT III, 600 V CAT IV internal 250 mA fuse. A defective fuse may only be (KS17-2) replaced by an authorized service center. Voltage at the • 2 batteries, 1.5 V, type AA measuring current circuit may not exceed 600Vrms • CD with operating instructions • 1 DKD calibration certificate • HC20 Hardcase Electrical Safety Applicable Regulations and Standards Per IEC 61010-1:2001/VDE 0411-1:2002 IEC/EN 61010, part Safety requirements for electrical 1:2001/VDE 0411- equipment for measurement, Measurement Installation Categories 1:2002 control and laboratory use Category II Operating voltage 600V DIN EN 61326 Electrical equipment for control VDE 0843, part 20 technology and laboratory use Category III Operating voltage 300 V – EMC requirements Test voltage 3.7 kV~ DIN EN 60529 Test instruments and test DIN VDE 0470, part 1 procedures – degrees of protection provided by enclosures (IP code) Warranty 24 months for materials and workmanship 1 to 3 years for calibration (depending upon application) Display LCD panel (65 mm x 30 mm) digital display including unit of measure, type of current and various special functions. Digital Display/char height 7-segment characters / 12 mm Resolution 6½ digits 1,200,000 counts Overflow display “OL” is displayed for ≥1,250,000 digits Polarity display “–” (minus sign) is displayed if pos. lead is connected to “ ” Refresh rate 1 times per sec. Ambient Conditions Operating temp. range -5° C ... +50° C Storage temp. range -25° C ... +70° C (without batteries) Relative humidity Max.75%, non condensing Electromagnetic Compatibility Interference emission EN 61326: May 2004, class B Interference immunity EN 61326: May 2004, appendix E IEC 61000-4-2: Dec. 2001 Feature A 8 kV atmospheric discharge 4 kV contact discharge IEC 61000-4-3: Dec. 2001 Feature B 3 V/m Mechanical Design Housing Impact resistant plastic (ABS) Dimensions 84 mm x 195 mm x 35 mm Weight Approx. 0.35 kg with batteries Protection IP 50 (terminals IP 20 Specifications 1.800.372.6832 sales@dranetz-bmi.com tel 732.287.3680 : fax 732.248.1834 1000 New Durham Road, Edison, New Jersey 08818 USA © 2008 Dranetz-BMI. All rights reserved. www.dranetz-bmi.com Printed in United States. Specifications are subject to change without notice. DranTech Ultra Rev 04-Aug-08
Thank you for viewing our pdf. To View the formatted version
download it now