DranTech Outdoor Brochure
We are happy to provide this downloadable file for your convenience. Please provide us with some basic information so that we may better address your needs now and in the future. Please enter your email address carefully as this will be where we send the download link. Dranetz respects your privacy. Your contact information will not be sold or rented. Only Dranetz or its authorized sales partners may use this information.
DranTech OUTDOOR Weather-resistant TRMS Digital Multimeter • Digital Hand-Held Multimeter with RMS Measurement: VAC TRMS, VAC+DC TRMS, VDC, Hz (V), Hz (A), Ω, V , °C/°F (TC) • 4 ½ -digit display (12,000 counts), with backlit display • Direct Current measurement with increased accuracy and Current measurement, via clip-on current transformer and sensors • Data Storage of Min-Max Values • Automatic or Manual Measuring Range Selection • Analog Scale for Quick Trend Indication – Bar Graph or Pointer • Rugged IP65 Housing with Protective Rubber Holster • Remote configured, and momentary and stored measurement data via the bidirectional infrared Interface with DranWin software Battery Capacity Indication – Power Saving Circuit Applications The battery load capacity is indicated on the display. If This multimeter is suitable for universal use in electrical user selected, the device is switched off automatically if engineering, electrical installation, laboratory applications, the measured value remains unchanged for a period of telecommunication, technical training, as well as for between 10 and 59 minutes (adjustable), and if none of troubleshooting in the field in potentially wet the controls are activated during this time. environments with the housing rating of IP65. DKD Calibration Certificate Features Multimeters are furnished with an internationally accepted DKD calibration certificate (recognized by EA and ILAC). Three Connector Terminals with patented Automatic After the specified calibration interval has elapsed Blocking Sockets * (recommended interval: 1 to 3 years), the multimeters All current ranges are implemented via a single connector can be inexpensively recalibrated by any calibration socket which prevents any possibility of operator error. laboratory. Beyond this, the automatic blocking sockets prevent incorrect connection of the measurement cables, as well Scope of Delivery as selection of the wrong measured quantity. Danger to • Multimeter with 1 pair of safety test leads (1.5 m) the user, the instrument and the device under test with 4 mm diameter, 1000 V CAT III, 600 V CAT resulting from operator error is therefore eliminated. IV (KS17-2) * Patented (patent no. DE 40 27 801 C2 and US 5,166,599) • 2 alkaline batteries, 1.5 V, type AA Overload Protection • CD with operating instructions, The instrument is safeguarded for up to 1000 V in all • DKD calibration certificate measuring functions by overload protection. Voltages of • Pack of 10 superfast Fuses 10A/1kV greater than 1000 V and current of greater than 10 or 16 • HC20 Hardcase A are indicated acoustically. Applicable Regulations and Standards IEC/EN 61010, part Safety requirements for electrical RMS Value with Distorted Waveforms 1:2001/VDE 0411- equipment for measurement, The measuring method applied allows for waveform 1:2002 control and laboratory use independent RMS measurement (TRMS AC and AC+DC) DIN EN 61326 Electrical equipment for control for voltage and current up to 20 kHz). VDE 0843, part 20 technology and laboratory use – EMC requirements Selectable Filter for V AC Measurement DIN EN 60529 Test instruments and test A 1 kHz low-pass filter can be activated if required, for DIN VDE 0470, part 1 procedures example when measuring motor voltage at variable – degrees of protection provided frequency drives (ASDs). by enclosures (IP code) Polarity display In auto-ranging mode Warranty With the symbol Overflow display 24 months for materials and workmanship Update rate 40 measurements per second and 1 to 3 years for calibration (depending upon application) display refresh Digital Internal Clock Display/char 7-segment characters / 15 mm Time format DD.MM.YYYY hh:mm:ss height Resolution 0.1 s Resolution 4 1/2 digits, 12,000 counts Accuracy ±1 min. per month Temperature Influence 50 ppm/K Overflow display “OL” is displayed for ≥12,000 Polarity display “–” (minus sign) is displayed if pos. Power Supply lead is connected to “ ” Battery 2 ea. 1.5 V, size AA, Measuring rate 10 and 40 measurements per alkaline manganese per IEC LR6 second with the Min-Max function (2 ea. 1.2 V NiMH rechargeable battery possible) except for the capacitance, Service life with alkaline manganese: approx. 200 hours frequency and duty cycle Battery test: Battery capacity display with battery symbol in 4 segments: . measuring functions Display of momentary battery voltage via menu function. Refresh rate 2 times per sec., every 500 ms Power OFF function: Multimeter is switched off automatically: – If battery voltage drops to below approx. 1.8 V Acoustic Signals – If none of the keys or the rotary switch are activated for an adjustable duration of 10 to 59 minutes, and the For voltage: Intermittent signal at above 1000 V multimeter is not in continuous operating mode For current: Intermittent signal at above 10 A Continuous signal at above 16 A Fuse Electrical Safety Fuse FF (UR) 10 A/1000 V AC/DC; 10 mm x 38 mm, Per IEC 61010-1:2001/VDE 0411-1:2002 Switching capacity: 30 kA at 1000 V AC/ DC, protects the current measurement input in the 100 μA through 10 A Cat. III 1000 V - Cat. IV 600 V ranges Test voltage 6.7 kV~ Display LCD panel (65 mm x 36 mm) with analog and digital display including unit of measure, type of current and various special functions Background illumination is switched off approximately 1 minute after it has been activated (backlit display) Analog Display LCD scale with bar graph or pointer, depending on the selected parameter setting Scaling With 4 division lines each, 1 bar/pointer corresponds to 500 digits at the digital display Electromagnetic Compatibility EMC Ambient Conditions (to meet all specs) Interference EN 61326: May 2004, class B Accuracy range 0 °C ... +40 °C emission Interference EN 61326: May 2004, appendix E Operating temp. -10° C ... +50° C immunity range IEC 61000-4-2: Dec. 2001 Storage temp. range -25° C ... +70° C (w/o batteries) Feature B 8 kV atmospheric discharge Relative humidity Max.100% 4 kV contact discharge IEC 61000-4-3: Dec. 2001 Elevation To 2000 m Feature A 3 V/m Deployment Indoors or Outdoors Mechanical Design Housing Impact resistant plastic (ABS) Dimensions 200 x 87 x 45 mm (without protective rubber holster) Weight Approx. 0.35 kg with batteries Protection Housing: IP 65 Specifications Specifications (cont’d) Data Interface Type Optical via infrared light through the housing Data transmission Serial, bidirectional (not IrDa compatible) Protocol Device specific Baud rate 38,400 baud Functions – Select/query measuring functions and parameters – Query momentary measurement data --Read out stored measurement data The USB plug-in interface adapter (see accessories) is used for adaptation to the PC’s USB port. Internal Measured Value Storage Memory capacity 4 MBit / 540 kB for approx. 15,400 measured values with date and time stamp 1.800.372.6832 sales@dranetz-bmi.com tel 732.287.3680 : fax 732.248.1834 1000 New Durham Road, Edison, New Jersey 08818 USA © 2008 Dranetz-BMI. All rights reserved. www.dranetz-bmi.com Printed in United States. Specifications are subject to change without notice. DranTech OUTDOOR Rev 9-May-08
Thank you for viewing our pdf. To View the formatted version
download it now