DranISO 5000D Brochure
We are happy to provide this downloadable file for your convenience. Please provide us with some basic information so that we may better address your needs now and in the future. Please enter your email address carefully as this will be where we send the download link. Dranetz respects your privacy. Your contact information will not be sold or rented. Only Dranetz or its authorized sales partners may use this information.
DranISO 5000D Digital High-Voltage Insulation Tester • Large measuring range from 0.4 MΩ ... 1 TΩ • Variable test voltages, or in fixed steps of 100 V, 250 V, 500 V, 1.0 kV, 1.5 kV, 2.0 kV, 2.5 kV, 5.0 kV • Polarization index and absorption ratio • Voltage measurements to 1000 V • Frequency measurement from 15 Hz to 1 kHz • Capacitance measurement from 0.1 to 5 μF • Measurement of electrical discharge • Guard terminal for the compensation of surface currents • 5 m extension cable included as accessory • Supply power from mains, internal set of storage batteries or external 12 V supply • Backlit dot matrix display • Digital display of measured values and limit values, characteristic curve display for polarization index • Timer function: 1 second to 100 minutes • DKD calibration certificate Applications Insulation measurement in large systems, and for cables, motors, generators etc. Features Polarization Index Test Voltages to 5000 V A polarization index test is recommended for electrical The instrument is suitable for non-destructive measurement machines. This procedure involves expanded testing of of insulation resistance in electrical systems, as well as in insulation resistance. DC measuring voltage from the DranISO machines, transformers, cables and electrical equipment 5000D is applied to the insulation for a duration of 10 minutes. utilized in, for example, locomotives, street cars and ocean Measured values are documented after one minute, and after going vessels with selectable test voltages of up to 5 kV. ten minutes. If the insulation is good, the value measured after ten minutes is higher than the value measured after one minute. Voltage Measurement to 1000 V The relationship between the two measurement values is the Testing for absence of voltage at the device under test in polarization index. Charged material within the insulation is systems of up to 1 kV can be performed with the voltage aligned due to the application of measuring voltage over a long measuring range. period of time, resulting in polarization. The polarization index indicates whether or not the charged material contained in the insulation can still be moved, thus allowing for polarization. Discharging Capacitive Devices Under Test This, in turn, is an indication of the condition of the insulation. Capacitive devices under test such as cables and coils, which may be charged by the test voltage, are discharged by Data Management and Report Generation the measuring instrument. The falling voltage value can be The data of each measurement can be stored under a selected observed at the display. object number. Furthermore, a description for this object can be entered via the keyboard of the optional PSI module Measurements per EN 61557 Parts 1 and 2 (VDE 0413) (Feature I1). The data management function allows for Nominal current amounts to 1 mA at a test voltage of 100 V, individual measurement data of a previously selected object to 250 V, 500 V or 1000 V. be displayed and to be deleted if required, or for previously entered objects to be deleted. Highly Insulated Measurement Cables Depending on the number of stored objects (max. 254), up to The highly insulated measurement cables are permanently 1,600 measurements can be stored. The current memory connected for safety reasons, and due to technical measuring occupancy is continuously displayed as a bar graph. considerations. Danger resulting from inadvertently disconnected cables, for example in the event of charging caused by capacitive devices under test, is thus avoided. Dranetz-BMI DranISO 5000D Digital High-Voltage Insulation Tester Characteristic Values Measuring Ranges: Breakdown Voltage Standard DIN EN 61557-1:1998-05 Parameters Setting Range Intrinsic Measuring Accuracy Accuracy DIN EN 61557-2:1998-05 Voltage range 100 … 5000 V ±(10% rdg. + 8 d) ±(15% rdg. + 10 d) VDE Regulation VDE 0413 Part 1:1998-05 VDE 0413 Part 2:1998-05 Rise time 5 … 300 s — — Measuring time 1 … 120 s / auto / — — Insulation Resistance cont. measure- ment Display Measuring Test Voltage Intrinsic Measuring Range [Ω] Range Accuracy Accuracy Capacitance Measurement 0.00 M ... 50.0 0.60 M ...10.0 G 100 V ... 250 V ±(7% rdg. + 6d) ±(10% rdg. + 8 d) G Display Measuring Test Intrinsic Measuring >10.0 G ... 50.0 G ±(7% rdg. + 6d) ±(10% rdg. + 8 d) Range Range Voltage Accuracy Accuracy 0.00 M ... 250 0.40 M ... 50.0 G > 250 V ... 1.00 ±(7% rdg. + 6d) ±(10% rdg. + 8 d) 100…450 ±(10% rdg. + 5 d) ±(15% rdg. + 8 d) 0.00 …10.0 0.10 …5.00 G kV V μF μF >50.0 G ... 250 G ±(7% rdg. + 6d) ±(10% rdg. + 8 d) 500…5 kV ±(5% rdg. + 5 d) ±(10% rdg. + 8 d) 0.00 M ... 999 0.40 M ... 200 G >1.00 kV ... ±(7% rdg. + 6d) ±(10% rdg. + 8 d) G 5.00kV Dielectric Discharge (DD) >200 G ... 999 G ±(7% rdg. + 6d) ±(10% rdg. + 8 d) Limit Test duration: automatic (until measured value is stable), DD 0.10 ... 2.00 ... 9.80 manual (1 to 120 s) or continuous measurement (lock function) Polarization Index (PI), Absorption Ratio (DAR) Reference Conditions t1 [min] t2 [min] Limit [min] Ambient PI 00:00 ... 01:00 ... 99:50 00:00 ... 10:00 ... 99:50 0.10 ... 4.00 ... 9.80 min min min temperature +73 °F(+23 °C) ± 2 ° DA 00:00 ... 00:30 ... 99:50 00:00 ... 01:00 ... 99:50 0.10 ... 1.60 ... 9.80 min Relative humidity 40 ... 60% min min R Measured quantity PI and DAR are calculated values. The specifications of the insulation measurement are ap- frequency 50 Hz ±10 Hz (during voltage plicable. measurement) Line voltage Insulation Test Voltage waveshape Sinusoidal, deviation between RMS and rec- Nominal Values Variable Nominal Intrinsic Accuracy tified value < 1% of Test Voltage Test Voltage Current 100 V, 250 V, 500 V, 1.00 ≥ 1.0 mA 0 ... +25% rdg. Power Supply kV 1.50 kV, 2.00 kV, 2.50 kV ≥ 0.4 mA ± 5% rdg. Line voltage 207 V … 253 V / 49 Hz … 61 Hz 5.00 kV ≥ 0.1 mA ± 3.5% rdg. or (depending on country-specific version) 100 V...1.00 kV ≥ 1.0 mA ± 15% rdg. 108 V … 132 V / 59 Hz … 61 Hz > 1.00 kV...2.50 kV ≥ 0.4 mA ± 5% rdg. Power consumption < 18 VA > 2.50 kV...5.00 kV ≥ 0.1 mA ± 3.5% rdg. Storage batteries NiMH 9.6 V, 3 Ah, charging period 6 hours Number of Variable test voltages are adjustable in increments of 50 V Short-circuit current up to 1.00 kV, test voltage ≤ 2 mA measurements at nominal current Voltage Measurement as per VDE 0413 700 Measuring range Impedance Intrinsic Measuring Accuracy Accuracy Ambient Conditions 50 V ... 5.00 kV test voltage ±(2.5% rdg. + 5 ±(5% rdg. + 5 d) d) Accuracy +32 °F ( 0 °C) ... + 104 °F (+ 40 °C) 50 V ... 1.00 kV ac/dc 1 MΩ ±(2.5% rdg. + 2 ±(5% rdg. + 5 d) Operating temperature +23 °F (-5 °C) ... + 104 °F (+ 40 °C) d) Storage temperature + 4 °F (-20 °C) ... + 140 °F (+ 60 °C) Frequency of measuring quantity: 15 Hz...1 kHz (without batteries) Relative humidity max. 75%, no condensation allowed Frequency Measurement Elevation 6500 ft (2000 m) Measuring Range Impedance Intrinsic Measuring Deployment indoors, outdoors: only in the specified abient Accuracy Accuracy conditions 15.0 Hz … 1.00 kHz 1 MΩ ±(0.5% rdg. + 2 ±(1% rdg. + 2 d) d) Voltage of measuring quantity: 50 V ... 1 kV Dranetz-BMI 2 DranISO 5000D Digital High-Voltage Insulation Tester Electrical Safety Standard IEC 1010-1:1990, IEC 1010-1/A2:1995 EN 61010-1:1993, EN 61010-1/A2:1995 VDE regulation VDE 0411 Part 1, 1994-03 Pollution degree 2 Protection IP 40 Overvoltage Rx category Insulation measurement – 5000 V DC – no overvoltage 0 kΩ 200 kΩ 400 kΩ 600 kΩ 800 kΩ 1 MΩ Voltage measurement – 600 V – CAT III Voltage measurement– 1000 V – CAT II Safety class II Rx Electromagnetic Compatibility (EMC) 0 kΩ 500 kΩ 1 MΩ 1,5 MΩ 2 MΩ 2,5 MΩ 3 MΩ Product standard EN 61326-1: 1997 EN 61326: 1997/A1: 1998 Interference Emission Class EN 55022 A Interference Immunity Test Value Power Feature EN 61000-4-2 Contact/Air - 4 kV/8 kV B EN 61000-4-3 10 V/m C EN 61000-4-4 Mains Connection - 2 kV B Rx EN 61000-4-5 Mains Connection - 1 kV B 0 MΩ 1 MΩ 2 MΩ 3 MΩ 4 MΩ 5 MΩ 6 MΩ EN 61000-4-6 Mains Connection - 3 V B EN 61000-4-11 0.5 Period / 100% A Mechanical Design Display Multiple display with dot matrix 128 x 64 pixels Dimensions W x H x D: 10 x 5.25 x 9.5 in (255 mm x 133 mm x 240 mm) Weight approx. 11.0 lbs (5 kg) with batteries Rx [MΩ] 0 5 10 15 20 25 30 35 40 Voltage applied to DUT during Insulation Resistance Test Measuring voltage U on DUT as a function of its resistance Rx at nominal voltages of 100 V, 500 V, 1000 V, 2400 V and 5000 V: Rx 0 kΩ 50 kΩ 100 kΩ 150 kΩ 200 kΩ 3 Dranetz-BMI DranISO 5000D Digital High-Voltage Insulation Tester Test Selection Setting of Parameters Display of Final Results Insulation Test High-Voltage Test Feature B1/B2 Polarisation Index Test Measurement of Breakdown Voltage Capacitance Measurement Voltage Measurement 4 Dranetz-BMI DranISO 5000D Digital High-Voltage Insulation Tester Included with Basic Instrument 1 high-voltage insulation measuring instrument with perma- nently connected measurement cables and test probes, 2 alligator clips (5 kV version) 1 mains power cable and 1 interface cable 1 operating instructions 1 DKD Calibration Certificate (The test instrument can be recalibrated by our calibration service at any time. We recommend a calibration interval of 1 to 2 years.) Dranetz-BMI Phone - 1 - 800 - 372 - 6832 1000 New Durham Road Fax - 1 - 732 - 248 - 1834 Edison, NJ 08818 USA sales@dranetz-bmi.com www.dranetz-bmi.com 5 06.28.2007
Thank you for viewing our pdf. To View the formatted version
download it now