Current Probe Brochure
We are happy to provide this downloadable file for your convenience. Please provide us with some basic information so that we may better address your needs now and in the future. Please enter your email address carefully as this will be where we send the download link. Dranetz respects your privacy. Your contact information will not be sold or rented. Only Dranetz or its authorized sales partners may use this information.
Current Probes for use with PX5/4400/PowerVisa and Encore Series 61000 There are many possible current probe options available from Dranetz-BMI to fulfill your current measurement requirements for both Dranetz-BMI PX5/4400 and Encore Series 61000 Monitoring instruments. Many of these current probes connect directly into the PX5/4400 and Encore Series 61000 instruments. For the Encore Series 61000 a 61MAC input module allows connection of the available current probes to the instrument. Clamp-On Clamp-on type probes are available to measure as low as 0.1 A to a maximum of 3000 Amps in various ranges. Also, there are available clamp-on probes that measure both AC and DC currents. Flexible Probes These type of probes are available in three lengths 24 inches, 36 inches, and 48 inch lengths which allow monitoring currents up to 6000 Amps full scale. AC Clamp-On Probes Clamp-on type probes are available in the following ranges as low as 0.1 A up to 3000 A RMS. All of the probes listed below plug directly into the PX5 family of products as well as the Series 61000 current module 61MAC. Amplitude Phase Maximum Product Frequency Range Accuracy Accuracy Conductor Number Range ± ± Size TR2500 10A to 500 Arms 1.5%of < 4º 10A to 500 Arms 48Hz-1kHz 30mm dia. reading +0.6A TR2500A 100A to 500A 1% 1.5° 10A to 500Arms 40Hz to 5KHz 50mm dia. 10A to 100A 2% 3° TR2501 1.2A 1.5% 1° 100mA to 1.2Arms 40Hz to 5KHz 15mm dia. 100mA 1.5% 2° TR2510 1A to 10 Arms 1A to 10 A 1% 1.5° 40Hz to 3 KHz 20 mm dia. TR2510A 5A to 10A 1.2% 1.5° 1A to 10Arms 40Hz to 5KHz 15mm dia. 1A to 5A 2% 1° 1000A to 3000A 0.5% 0.5° TR2520A 100A to 3000Arms 40Hz to 5KHz 72mm dia.* 300A to 1000A 0.75% 0.75° 100A to 300A 1.5% 1.5° TR2530A 50A to 300A 1% 0.5° 20A to 300Arms 30Hz to 5KHz 54mm dia. 20A to 50A 1.5% 0.6° TR2540A 100A to 1000A 1% 0.4° 10A to 1000A 30Hz to 5KHz 54mm dia. 10A to 100A 1.5% 0.5° TR2550A 10A to 100A 1% 2.5° 1A to 100Arms 40Hz to 10KHz 15mm dia. 1A to 10A 2% 5° Transient Accuracy: ±10% of Reading, ±0.5% Full scale, ≥10 uSec * or bus bar The probes listed below were originally designed to plug directly into a Dranetz-BMI Model 658 and require an adapter cable. The CA4300 adapter cable converts the model 658 probe connector to a hypertronics type connector that allows the following probes to plug directly into the PX5 family of products as well as the Series 61000 current module 61MAC. Amplitude Phase Maximum Product Frequency Range Accuracy Accuracy Conductor Number Range ± ± Size 300A 1% 1.5° TR2019B 50A to 300A 30Hz to 5KHz 52mm 200A 1.5% 1.5° 50A 3% 3° TR2021 1A to 30A 1A to 30A 1% 3° 40Hz to 10KHz 20mm dia. 200A to 1000A 0.75% 0.75° TR2022A 10A to 1000A 30Hz to 5KHz 54mm dia. 50A to 200A 1.5% 1.5° 10A to 50A 3% 3° TR2023 200A to 3000A 200A to 3000A 1% 1° 30Hz to 5KHz 65mm dia.* CA4300 Required to allow connection of TR2019B, TR2021, TR2022A, or TR2023 current probe to PX5 family or Encore Series 61000 module 61MAC Transient Accuracy: ±10% of Reading, ±0.5% Full scale, ≥10 uSec * or bus bar AC / DC Clamp-On Probes Clamp-on type probes are available in two ranges 150A and 1500 A AC/DC and available battery power only or powered by 9 VDC wall adapter only. Amplitude Phase Maximum Product Frequency Range Accuracy Accuracy Conductor Number Range ± ± Size PR150/SP1 15A to 150A DC to 5KHz 52mm dia. 15A to 150A 1% 3° * Requires AC Adapter PR150/SP2 15A to 150A DC to 5KHz 52mm dia. 15A to 150A 1% 3° 9V Battery Only PR1500/SP7 150A to 1500A DC to 5KHz 52mm dia. 150A to 1500A 1% 3° * Requires AC Adapter PR1500/SP8 150A to 1500A DC to 5KHz 52mm dia. 150A to 1500A 1% 3° 9V Battery Only Transient Accuracy: ±10% of Reading, ±0.5% Full scale, ≥10 uSec Additional available accessory for the flexible probe allows the probe to be powered by an ac adapter ideal for long term monitoring and worry free from batteries being depleted. Product Input Output Input Voltage Polarity Output Number Plug Type Plug Type 5.5 mm X Center pin +9 VDC ACADP-PR9V- 120 VAC, 60 Hz US 2.1 mm positive 200 mA US (female) 5.5 mm X Center pin +9 VDC ACADP-PR9V- 230 VAC, 50 Hz EURO 2.1 mm positive 500 mA EU (female) 5.5 mm X Center pin +9 VDC ACADP-PR9V- 230 VAC, 50 Hz UK 2.1 mm positive 500 mA UK (female) * One AC adapter required per probe. Flexible Probes These types of probes are available in three lengths 24 inches, 36 inches, and 48 inch lengths and available in two maximum ranges of 3000 A RMS and 6000 A RMS. Each probe can be powered by battery or AC adapter and multiple probes can be powered by a single AC adapter. Amplitude Phase Product Frequency Range Accuracy Accuracy Maximum Conductor Size Number Range ± ± DRANFLEX ± 1 reading 3000XL 3A to 30A ±0.1 A °1 3A to 10 Hz 24 in. length up to 8 in. diameter 30A to ± 1 reading 3000A To 36 in. length up to 11 in. diameter 300A ±0.1 A °1 (3 ranges) 10 kHZ 48 in. length up to 17 in. diameter 300 to ± 1 reading 3000A ± 1 A °1 DRANFLEX ± 1 reading 6000XL 6A to 60A ±0.1 A °1 6A to 10 Hz 24 in. length up to 8 in. diameter 60A to ± 1 reading 6000A To 36 in. length up to 11 in. diameter 600A ±0.1 A °1 (3 ranges) 10 kHZ 48 in. length up to 17 in. diameter 600A to ± 1 reading 6000A ± 1 A °1 RR3035A 3A to 30A ± 0.3A °1 3A to 10 Hz 24 in. length up to 8 in. diameter 30A to 3000A To 36 in. length up to 11 in. diameter 300A ± 3 A °1 (3 ranges) 50 kHZ 48 in. length up to 17 in. diameter 300 to 3000A ± 30 A °1 6A to 60A ± 0.6A °1 RR6035A 6A to 10 Hz 24 in. length up to 8 in. diameter 60A to 6000A To 36 in. length up to 11 in. diameter 600A ± 6 A °1 (3 ranges) 50 kHZ 48 in. length up to 17 in. diameter 600A to 6000A ± 60 A °1 Required to allow connection of RR3035A or RR6035A flexible probes to CA4300BNC PX5 family or Encore Series 61000 module 61MAC instruments. One adapter cable required for each probe to be connected to the PX5 or Encore Series instruments. Transient Accuracy: ±10% of Reading, ±0.5% Full scale, ≥10 uSec Additional available accessory for the flexible probe allows the probe to be powered by an ac adapter ideal for long term monitoring and worry free from batteries being depleted. Product Input Output Output Input Range Polarity Number Plug Type Plug Type Voltage 5.5 mm X Center pin +3 VDC 120 VAC, 60 Hz US 2.1 mm RR/PSUS negative 1 A (female) 5.5 mm X Center pin +3 VDC 230 VAC, 50 Hz EURO 2.1 mm RR/PSEURO negative 1 A (female) 5.5 mm X Center pin +3 VDC 230 VAC, 50 Hz UK 2.1 mm RR/PSUK Negative 1 A (female) Flexible Probe 3 VDC Power Cable for Encore Series Allows 3 VDC power connections up to four flexible probes from Encore Series 61000 instrument only. This cable connects directly from the Encore Series 61000 mainframe and up to four flexible probes. Power Product Number Output Plug Type Polarity Connection 5.5 mm Connects to Center pin X 61PS module of DC3VFLEX Negative Encore Series 2.1 mm 61000 only (female) Flexible Probe 3 VDC Power Cable for PX5 family Allows 3 VDC power connections up to four flexible probes from PX5 instrument only. This cable connects to either the AC Adapter output of RR/PSUS, RR/PSEURO, or RR/PSUK 3VDC adapters and up to four flexible probes. Power Product Number Output Plug Type Polarity Connection Connects to 5.5 mm Center pin RR/PSUS X RR/PSEURO Negative RR/PS/4A RR/PSUK 2.1 mm 3VDC AC (female) Adapter Note: Not for use with PR150 or PR1500 series probes each probe is required to be powered individually by a single AC adapter for each probe. Specifications are subject to change without notice. 1.800.372.6832 sales@dranetz-bmi.com tel 732.287.3680 : fax 732.248.1834 1000 New Durham Road, Edison, New Jersey 08818 USA © 2009 Dranetz-BMI. All rights reserved. www.dranetz-bmi.com Printed in United States. CurrentProbeBrochure Rev 17-Jan-2009
Thank you for viewing our pdf. To View the formatted version
download it now