Customize the PP1 to suit your needs. Insert a Dranetz TASKCard®, and the PP1 becomes a different device with a new set of functions. TASKCards include PQPlus, 8000(Energy/Harmonics), Inrush, and TASKCard Flicker.
Upgrade Now!
Dranetz has Discontinued this product and we strongly recommend that you
consider upgrading your instrument to the recommended product upgrade:
PowerVisa,
PowerGuide4400,
PX5,
EP1.
Please note: This is a discontinued product. Options/Accessories associated with this product may no longer be available.
Dranetz provides several options to help you upgrade your product affordably. We can work with you to determine the best solution for your situation. Contact our Sales department today as ask about our trade-in options. If you are unable to upgrade, please be aware that your instrument should be serviced and calibrated yearly for optimal accuracy, and you may be eligible for service incentives. Please contact our sales department to discuss your situation.
4 fully differential channels 10-600Vrms Accuracy: ±1% reading ±0.05% full scale
50-6000Vpk 1 microsecond minimum duration Accuracy: ±10% reading ±1% full scale Requires TASKCard PQPlus
4 fully independent current channels 10 - 200% of full-scale current probe rating Accuracy: ±1% reading ±0.05% full scale (at fundamental, plus current probe accuracy)
10-300% CT full scale except Chan D 2-200% CT full scale
1 microsecond minimum duration
Accuracy: ±10% reading ±1% full scale plus probe Requires TASKCard PQPlus
Fundamental range 30 - 450 Hz
Accuracy ±0.2% of reading
All parameters updated once per second (Harmonic-based parameters updated every 5 seconds)
41°F to 113°F
+5°C to +45°C
Humidity 10% - 90% non-condensing
2 hours operation
3 hours full recharge (continuos operation from battery eliminator)
Dranview
UL, CE, FCC, ISO-9100 (CE certification for model PP1E, UL listing for model PP1)
Real-time viewing of
A true handheld three-phase volt-amp-power-harmonic meter lets you view values updated every second: volts, amps, watts, VA, var, power factor, frequency, voltage unbalance, V&I Total harmonic distortion, current crest factor, K factor, demand, energy and nth harmonics. The available parameters depend on the TASKCard you have selected.
Recorded data can be viewed to quickly show problems
Displays a graph of the selected parameter since recording began
Please note: This is a discontinued product. Options/Accessories associated with this product may no longer be available.
Factory-installed built-in" thermal text/graphic, high speed, high resolution printer.
Field surveys, diagnostics, analysis. On-the-spot reports
Transient events, harmonics, power flow K-factor, voltage and current transients, THD and up to 50th harmonic, PF, kW, kVA, kVAR pre- and post-fault data.
Field service of sensitive electronic systems, Industrial automation, health care facilities
Scope mode, phasor diagrams, long-term trends, demand, kWh, power factor
Energy savings verfications Harmonic troubleshooting: adjustable speed drives, resonance
Monitors sudden changes in an electrical parameter: Scope mode, phasor diagrams, trigger and pre-trigger, Cycle-by-cycle recording on up to 6 channels
Motor start-up, Transformers, breakers, protective relays
Voltage fluctuations / light flicker, in accordance with EN60868 (formerly IEC868) and IEC 1000-4-15. Perception curves for 230V/50Hz or 120V/60Hz lighting.
Arc-furnace studies, Compliance measurements, certification
PCMCIA Memory card provides removable memory expansion to internal memory. Available in 2Mb and 4Mb
Rugged cordura nylon carry case- holds PP1, voltage probes, CTs, and manual. Ideal for field service, industrial applications.
Extended battery use; internal PP1 recharger.
Current probe, 1A - 10A RMS 45Hz-3kHz; Max conductor size 0.47"
Current probe, 3A - 150A RMS 45Hz-3kHz; Max conductor size 0.47"
Current probe, 10A-300A RMS 45Hz-50kHz; Max conductor size 2.0"
Current probe, 50A - 1000A RMS 30Hz-3kHz; Max conductor size 2.0"
Current probe, 100A - 3000A RMS 48Hz-3kHz; Max conductor size 2.56" or 1.97"x5.3"
Flexible current probe 1A - 300A, 10A - 3000A; 8Hz-7kHz; Inside diameter 6" (Requires adapter cable CAPP1LEM)