The 8010 PQNode is permanently installed at one location; the 8020 PQNode can be transported for monitoring several locations. Otherwise, their performance and specifications are identical.
Upgrade Now!Dranetz has Discontinued this product and we strongly recommend that you consider upgrading your instrument to the recommended product upgrade: Encore 61000 SG, Encore 61000 STD.
Please note: This is a discontinued product. Options/Accessories associated with this product may no longer be available.
Dranetz provides several options to help you upgrade your product affordably. We can work with you to determine the best solution for your situation. Contact our Sales department today as ask about our trade-in options. If you are unable to upgrade, please be aware that your instrument should be serviced and calibrated yearly for optimal accuracy, and you may be eligible for service incentives. Please contact our sales department to discuss your situation.
Phase A, B, C, Neutral, and Ground (supports single phase, split single phase, 3-phase 4-wire wye, 3-phase 3-wire delta)
Phase A, B, C, and Neutral using built-in 25 Amp (pk), 10 amp RMS pass-though CT's
0 - 600 Vrms (±1,000 Vpk) or 0 - 170 Vrms (±250 Vpk), user selected 50/60 Hz
50 - 6000Vpk
Peak detection, IEEE 587 type A and B
Accuracy: ±5% reading ±5% full scale
256 samples per cycle, continuous on all voltage channels; 128 samples per cycle, continuous on all current channels; Phase-locked sampling technique employed
Through 127th voltage harmonic, 63rd current harmonic at 50/60 Hz
Voltage-only, waveshape fault, swell, sag, interruption, impulse, periodic waveshape capture, cold load pickup
0 - 15 cycles voltage and current, user selectable. Additional post-trigger rms data available on swell, sags, and cold-load pickup.
90 Vrms - 250 Vrms, 45 Hz - 65 Hz
Power factor > 0.97
Power consumption < 40 VA
Impulse tolerance 6 kV
Suitable for attaching directly to monitored circuit.
Optional NEMA-4X Rain-,dust-,ice-resistant enclosure
-22°F to 122°F (-30°C to +50°C)
Humidity 0% - 95% non-condensing.
PASS (limited support in PES)
FCC, ISO-9001
Utilities mount 8010 PQNodes outdoors on power poles. Regardless of weather, the 8010 provides detailed, accurate, standard-setting power quality data.
Indoor mounting of the 8010 PQNode at substations and critical customer loads works well, too. Note the neat, easy-to-use built-in current transformers; just pass the 0 - 10 Amp conductor through the insulated tube, and the 8010 PQNode will take care of the rest.
Please note: This is a discontinued product. Options/Accessories associated with this product may no longer be available.
Internal modem with error-correcting, data compressing and surge protection.
B-801 provides 15 minutes operation in the event of a power failure.
B-802 provides one hour operation in the event of power failure.
B-803 provides 8 hours of operation in the event of power failure.