Energy Plaform (EP1) Software Upgrade How To
Release: V4.1.2
Important:
Data cards must be inserted in SLOT 1 to start monitoring and saving data.
Instruments Supported:
Firmware Installation Instructions
What you will need:
- Dranetz Compact Flash (CF) Data Card.
- Dranetz Compact Flash Reader/Writer for your computer
- There are now two different files available English / European and English / Asian.
- English / European - version includes the following languages.
English, French, Finnish, German, Italian, Polish, Spanish, and Swedish
- English / Asian - version includes the following languages.
English, Chinese ( Simplified & Traditional ), Japanese, Korean, and Thai.
- Note: Units shipped within North America are factory set using the English / European version.
IMPORTANT
- There are two different .zip files available EP1EuroV4_1_2.zip (English / European) and EP1AsiaV4_1_2.zip (English / Asian).When downloading be sure to download the applicable file that supports the desired language.
- If the firmware upgrade is interrupted the instrument may become unusable and require factory repair.
- It is recommended the instrument is connected to the AC power source or the instrument has a fully charged battery prior to upgrading the firmware.
- Do not remove the CF Data Card or turn off the instrument during the firmware installation process.
Procedure:
- Download the new firmware file EP1EuroV4_1_2.zip (English / European) or EP1AsiaV4_1_2.zip (English / Asian) to a temporary folder on your computer. Once the applicable file is downloaded to your computer you will need to unzip the file and extract the applicable hostcode.bin file and copy it to the compactflash card.
The European version file size is approximately 1.3 Mbytes while the Asian version is approximately 3 Mbytes.
- Format the compact flash data card in your instrument. Refer to this document for Important formatting and saving data instructions (.pdf)
- When formatting is complete remove the CF data card from the instrument and install in the CF reader/writer that is connected to your computer.
- Copy the firmware file hostcode.bin to the CF data card.
- When copying is complete, remove the CF data card from the CF reader/writer and install in SLOT 1 (upper slot) of your instrument.
Note: Data cards must be inserted in SLOT 1 to start monitoring and saving data.
- Turn off the instrument, wait a few seconds then turn back on.
- The instrument will automatically detect the presence of the new firmware file and display the message New Version Detected. Copy To Internal Memory. Yes/No.
- Press Yes to install the firmware. Do not touch the instrument until the message Installation Complete is displayed. Press OK when this message appears.
- The instrument will now boot operating under the new firmware.
- After loading new firmware any data card inserted in the instrument needs to be formatted to resume monitoring.